ACISFP temperatures check

Summary

Date start 2023:114:02:25:59.216
Date stop 2023:120:21:34:02.416
Model status NOT OK
Load directory /data/acis/LoadReviews/2023/APR2423/ofls
Run time Fri Apr 21 11:27:52 2023 by acisdude
Run log run.dat
Temperatures temperatures.dat
Earth Solid Angles earth_solid_angles.dat
States states.dat

"Hot" ACIS Observations (-109 C limit)

Obsid CCDs # of counts in seq Grating Cycle Spectra Max Count
25213 S2,S3 5 NONE 23 0
27815 S2,S3 5 NONE 23 0
25203 S2,S3 10 NONE 23 0
26875 S2,S3 76 NONE 24 76
27710 S1,S2,S3,S4 50 NONE 23 0
27709 S1,S2,S3,S4 50 NONE 23 0
27744 I0,I1,I2,I3,S2 137 NONE 23 140
27812 S2,S3 1000 NONE 24 1000
27813 S2,S3,S4 30 NONE 24 30
27811 S2,S3 1000 NONE 24 1000

FPTEMP Planning High (-86.0 C) Violations

Date start Date stop Duration (ks) Max temperature Obsids
2023:120:08:44:22.816 2023:120:08:49:50.816 0.33 -85.52  

No FPTEMP ACIS-I (-112.0 C) Violations

FPTEMP ACIS-S (-111.0 C) Violations

Date start Date stop Duration (ks) Max temperature Obsids
2023:115:07:00:54.816 2023:115:07:22:46.816 1.31 -109.89 26624
2023:117:22:42:06.816 2023:117:22:47:34.816 0.33 -110.65 27818

No FPTEMP ACIS-S Hot (-109.0 C) Violations

No FPTEMP Science Orbit ECS (-118.2 C) Violations

fptempM120toM107.png pow_sim.png roll_taco.png

ACISFP Model Validation

MSID quantiles

Note: Quantiles are calculated using only points where -120.0 C <= FPTEMP <= -100.0 C.

MSID 1% 5% 16% 50% 84% 95% 99%
fptemp -3.22 -2.03 -0.84 0.04 0.85 1.31 1.78
pitch -5.668 -0.191 -0.003 -0.000 0.003 0.282 5.805
tscpos -1 -1 -1 0 0 1 1
roll -1.019 -0.058 -0.004 -0.000 0.005 0.095 1.282

Validation Violations

MSID Quantile Value Limit
PITCH 1 -5.668 3.00
PITCH 99 5.805 3.00

FPTEMP

Note: FPTEMP residual histograms include only points where -120.0 C <= FPTEMP <= -100.0 C.

fptemp_valid.png fptemp_valid_hist.png

PITCH

pitch_valid.png pitch_valid_hist.png

TSCPOS

tscpos_valid.png tscpos_valid_hist.png

ROLL

roll_valid.png roll_valid_hist.png

ACIS CCD/FEP Count

ccd_count_valid.png

Earth Solid Angle

earth_solid_angle_valid.png

ADDITIONAL PLOTS

Additional plots of FPTEMP vs TIME for different temperature ranges

fptempM120toM119.png fptempM120toM79.png