ACISFP temperatures check

Summary

Date start 2023:288:18:46:54.216
Date stop 2023:295:18:33:47.116
Model status OK
Load directory /data/acis/LoadReviews/2023/OCT1623/ofls
Run time Thu Oct 12 12:59:38 2023 by acisdude
Run log run.dat
Temperatures temperatures.dat
Earth Solid Angles earth_solid_angles.dat
States states.dat

"Hot" ACIS Observations (-109 C limit)

Obsid CCDs # of counts in seq Grating Cycle Spectra Max Count
26501 I0,I1,I2,I3 350 NONE 24 70
28974 S2,S3 493 NONE 24 493
28989 S2,S3 493 NONE 24 493
28990 S2,S3 493 NONE 24 493
28976 S2,S3 1210 NONE 24 1210
26937 S1,S2,S3 503 NONE 24 500
28982 S1,S2,S3 503 NONE 24 500
25884 I0,I1,I2,I3,S2 137 NONE 23 140
27162 I0,I1,I2,I3 7 NONE 24 100
28985 I0,I1,I2,I3 7 NONE 24 100
27164 I0,I1,I2,I3 7 NONE 24 100
28480 S1,S2,S3,S4 50 NONE 23 0
28986 I0,I1,I2,I3 7 NONE 24 100
28983 S1,S2,S3 503 NONE 24 500
28984 I2,I3,S1,S2,S3 503 NONE 24 500
28975 S1,S2,S3,S4 18700 HETG 24 18700

No FPTEMP Planning High (-86.0 C) Violations

No FPTEMP ACIS-I (-112.0 C) Violations

No FPTEMP ACIS-S (-111.0 C) Violations

No FPTEMP ACIS-S Hot (-109.0 C) Violations

No FPTEMP Science Orbit ECS (-118.2 C) Violations

fptempM120toM107.png pow_sim.png roll_taco.png

ACISFP Model Validation

MSID quantiles

Note: Quantiles are calculated using only points where -120.0 C <= FPTEMP <= -100.0 C.

MSID 1% 5% 16% 50% 84% 95% 99%
fptemp -2.20 -1.42 -0.73 0.21 1.49 2.48 4.30
pitch -4.585 -0.103 -0.004 0.000 0.004 0.341 5.373
tscpos -1 -1 -1 -1 0 0 1
roll -1.172 -0.132 -0.006 0.000 0.005 0.071 1.015

Validation Violations

MSID Quantile Value Limit
PITCH 1 -4.585 3.00
PITCH 99 5.373 3.00

FPTEMP

Note: FPTEMP residual histograms include only points where -120.0 C <= FPTEMP <= -100.0 C.

fptemp_valid.png fptemp_valid_hist.png

PITCH

pitch_valid.png pitch_valid_hist.png

TSCPOS

tscpos_valid.png tscpos_valid_hist.png

ROLL

roll_valid.png roll_valid_hist.png

ACIS CCD/FEP Count

ccd_count_valid.png

Earth Solid Angle

earth_solid_angle_valid.png

ADDITIONAL PLOTS

Additional plots of FPTEMP vs TIME for different temperature ranges

fptempM120toM119.png fptempM120toM79.png