BEP_PCB temperatures check

Summary

Date start 2017:274:22:35:00.000
Date stop 2017:281:23:27:12.020
Model status OK (Planning Limit = 42.0 C)
Load directory /data/acis/LoadReviews/2017/OCT0217/ofls
Run time Wed Sep 27 09:06:27 2017 by acisdude
Run log run.dat
Temperatures temperatures.dat
States states.dat

No TMP_BEP_PCB Violations

tmp_bep_pcb.png pow_sim.png

BEP_PCB Model Validation

MSID quantiles

Note: BEP_PCB quantiles are calculated using only points where TMP_BEP_PCB > 20.0 degC.

MSID 1% 5% 16% 50% 84% 95% 99%
TMP_BEP_PCB -3.45 -2.57 -1.67 -0.72 0.75 2.80 5.12
PITCH -4.257 -0.209 -0.062 0.094 0.174 0.211 2.537
TSCPOS -1 -1 -1 0 0 0 1
ROLL -0.889 -0.479 -0.281 -0.113 0.297 0.538 0.907

Validation Violations

MSID Quantile Value Limit
TMP_BEP_PCB 1 -3.45 2.00
TMP_BEP_PCB 99 5.12 2.00
PITCH 1 -4.257 3.00

TMP_BEP_PCB

Note: BEP_PCB residual histograms include only points where TMP_BEP_PCB > 20.0 degC.

Red = telemetry, blue = model

tmp_bep_pcb_valid.png tmp_bep_pcb_valid_hist_log.png tmp_bep_pcb_valid_hist_lin.png

PITCH

Note: BEP_PCB residual histograms include only points where TMP_BEP_PCB > 20.0 degC.

Red = telemetry, blue = model

pitch_valid.png pitch_valid_hist_log.png pitch_valid_hist_lin.png

TSCPOS

Note: BEP_PCB residual histograms include only points where TMP_BEP_PCB > 20.0 degC.

Red = telemetry, blue = model

tscpos_valid.png tscpos_valid_hist_log.png tscpos_valid_hist_lin.png

ROLL

Note: BEP_PCB residual histograms include only points where TMP_BEP_PCB > 20.0 degC.

Red = telemetry, blue = model

roll_valid.png roll_valid_hist_log.png roll_valid_hist_lin.png