BEP_PCB temperatures check

Summary

Date start 2017:281:23:24:12.020
Date stop 2017:288:04:20:19.380
Model status OK (Planning Limit = 42.0 C)
Load directory /data/acis/LoadReviews/2017/OCT0917/ofls
Run time Tue Oct 3 16:23:44 2017 by acisdude
Run log run.dat
Temperatures temperatures.dat
States states.dat

No TMP_BEP_PCB Violations

tmp_bep_pcb.png pow_sim.png

BEP_PCB Model Validation

MSID quantiles

Note: BEP_PCB quantiles are calculated using only points where TMP_BEP_PCB > 20.0 degC.

MSID 1% 5% 16% 50% 84% 95% 99%
TMP_BEP_PCB -3.38 -2.26 -1.48 -0.73 0.55 1.72 3.55
PITCH -3.657 -0.181 -0.048 0.080 0.182 0.226 3.425
TSCPOS -1 -1 -1 -1 0 0 1
ROLL -1.171 -0.486 -0.283 -0.064 0.309 0.573 1.040

Validation Violations

MSID Quantile Value Limit
TMP_BEP_PCB 1 -3.38 2.00
TMP_BEP_PCB 99 3.55 2.00
PITCH 1 -3.657 3.00
PITCH 99 3.425 3.00

TMP_BEP_PCB

Note: BEP_PCB residual histograms include only points where TMP_BEP_PCB > 20.0 degC.

Red = telemetry, blue = model

tmp_bep_pcb_valid.png tmp_bep_pcb_valid_hist_log.png tmp_bep_pcb_valid_hist_lin.png

PITCH

Note: BEP_PCB residual histograms include only points where TMP_BEP_PCB > 20.0 degC.

Red = telemetry, blue = model

pitch_valid.png pitch_valid_hist_log.png pitch_valid_hist_lin.png

TSCPOS

Note: BEP_PCB residual histograms include only points where TMP_BEP_PCB > 20.0 degC.

Red = telemetry, blue = model

tscpos_valid.png tscpos_valid_hist_log.png tscpos_valid_hist_lin.png

ROLL

Note: BEP_PCB residual histograms include only points where TMP_BEP_PCB > 20.0 degC.

Red = telemetry, blue = model

roll_valid.png roll_valid_hist_log.png roll_valid_hist_lin.png