FP_TEMP temperatures check

Summary

Date start 2017:036:03:25:00.000
Date stop 2017:043:17:40:09.313
FP_TEMP status OK
Run time Tue Jan 31 19:54:16 2017 by acisdude
Run log run.dat
Temperatures temperatures.dat
States states.dat

No ACIS-I -114 deg C FP_TEMP Violations

No ACIS-S -112 deg C FP_TEMP Violations

FP TEMP Sensitive, -118.7 deg. C Preference Not Met:

Date start Date stop Max temperature OBSID
2017:027:06:16:54.816 2017:028:19:27:18.816 -114.39 19992
2017:038:05:35:34.816 2017:038:22:48:46.816 -114.44 19997
2017:041:04:23:10.816 2017:041:19:41:34.816 -115.11 20007
2017:042:02:31:34.816 2017:042:07:26:46.816 -117.24 20003

FP_TEMP -118.7 deg C Violations for Perigee Passages

Date start Date stop Max temperature
2017:022:04:27:58.816 2017:026:05:51:50.816 -109.57
2017:026:16:36:54.816 2017:026:18:42:38.816 -118.05
2017:029:07:07:02.816 2017:029:09:40:06.816 -117.51
2017:029:21:19:50.816 2017:032:06:38:22.816 -114.95
2017:034:14:13:02.816 2017:034:19:30:06.816 -116.74
2017:037:04:04:54.816 2017:037:11:38:38.816 -115.51
2017:039:19:46:06.816 2017:040:01:57:50.816 -116.23
2017:042:02:31:34.816 2017:042:07:26:46.816 -117.24
fptempM120toM112.png pow_sim.png

FP_TEMP Model Validation

MSID quantiles

MSID 1% 5% 16% 50% 84% 95% 99%
FPTEMP -1.95 -0.93 -0.35 0.13 0.53 1.26 3.16
PITCH -2.918 -0.868 -0.090 0.167 0.345 0.620 2.282
TSCPOS -1 -1 -1 -1 0 0 1

No Validation Violations

FPTEMP

Red = telemetry, blue = model

fptemp_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

fptemp_valid_hist_log.png fptemp_valid_hist_lin.png

PITCH

Red = telemetry, blue = model

pitch_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

pitch_valid_hist_log.png pitch_valid_hist_lin.png

TSCPOS

Red = telemetry, blue = model

tscpos_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

tscpos_valid_hist_log.png tscpos_valid_hist_lin.png

ADDITIONAL PLOTS

Additional plots of FPTEMP vs TIME for different temerature ranges

fptempM120toM119.png fptempM120toM90.png