FP_TEMP temperatures check

Summary

Date start 2018:182:08:05:00.000
Date stop 2018:190:06:26:10.396
FP_TEMP status OK
Load directory /data/acis/LoadReviews/2018/JUL0218/ofls
Run time Thu Jun 28 21:59:43 2018 by acisdude
Run log run.dat
Temperatures temperatures.dat
States states.dat

No ACIS-I -114 deg C FP_TEMP Violations

No ACIS-S -112 deg C FP_TEMP Violations

No Focal Plane Sensitive Observation -118.7 deg C FP_TEMP Preferences Unmet

No ECS Observation -118.7 deg C FP_TEMP Violations

fptempM120toM111.png pow_sim.png roll.png

FP_TEMP Model Validation

MSID quantiles

MSID 1% 5% 16% 50% 84% 95% 99%
FPTEMP -0.80 -0.51 -0.17 0.09 0.92 1.29 2.33
PITCH -3.643 -0.207 -0.132 0.107 0.188 0.237 3.709
TSCPOS -1 -1 -1 0 0 0 1
ROLL -1.864 -0.569 -0.389 0.100 0.277 0.610 1.771

Validation Violations

MSID Quantile Value Limit
PITCH 1 -3.643 3.00
PITCH 99 3.709 3.00

FPTEMP

Red = telemetry, blue = model

fptemp_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

fptemp_valid_hist_log.png fptemp_valid_hist_lin.png

PITCH

Red = telemetry, blue = model

pitch_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

pitch_valid_hist_log.png pitch_valid_hist_lin.png

TSCPOS

Red = telemetry, blue = model

tscpos_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

tscpos_valid_hist_log.png tscpos_valid_hist_lin.png

ROLL

Red = telemetry, blue = model

roll_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

roll_valid_hist_log.png roll_valid_hist_lin.png

ADDITIONAL PLOTS

Additional plots of FPTEMP vs TIME for different temerature ranges

fptempM120toM119.png fptempM120toM90.png