-------------------------------------------------                     
ACIS LOAD REVIEW OUTPUT:                                              
FOR REVIEW BY CXC ACIS OPS PERSONNEL                                  
                                                                      
-------------------------------------------------                     
                                                                      
USING /data/acis/LoadReviews/2016/OCT1516/oflsa/CR289_1615.backstop   
                                                                      
LOAD HISTORY FROM: /data/acis/LoadReviews/2016/OCT1516/oflsa/ACIS-History_edit.txt
                                                                      
-- CHANDRA LOAD START --                                              
                                                                      
CHANDRA STATUS ARRAY AT START OF LOAD REVIEW (FROM PREVIOUS LOAD HISTORY FILE):
(FP SI,HETG status,LETG status,current OBSID,RadMon status,current TLM FMT,Dither)
		 = (HRC-S,HETG-OUT,LETG-OUT,50618,OORMPDS,CSELFMT2,ENAB)            
                                                                      
2016:289:16:12:06.373    8971450  COMMAND_HW  CSELFMT4                
                                                                      
2016:289:16:12:06.373    8971450  MP_OBSID    50617                   
                                                                      
LATEST OCAT INFO FOR OBSID 50617:                                     
No ocat info found for obsid 50617                                    
                                                                      
                                                                      
2016:289:16:13:07.912    8971691  COMMAND_SW  4OLETGIN                
                                                                      
2016:289:16:17:06.373    8972621  COMMAND_HW  CSELFMT2                
                                                                      
2016:289:16:33:07.104    8976370  ACISPKT     AA00000000              
                                                                      
2016:289:16:33:07.104    8976370  ORBPOINT    XEF1000                 
2016:289:16:33:11.104    8976386  ACISPKT     AA00000000              
                                                                      
2016:289:16:33:15.104    8976402  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:289:16:33:39.104    8976495  ACISPKT     WSPOW0CF3F              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps; std I array                      
                                                                      
2016:289:16:34:42.104    8976741  ACISPKT     WBTX_QUIET              
2016:289:16:34:46.104    8976757  ACISPKT     WT007AC024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x007ac024                            
   fepCcdSelect               =    3    7    0    1    2    6         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 32                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3750                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:289:16:34:50.104    8976772  ACISPKT     XTZ0000005              
                                                                      
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-IN,50617,OORMPDS,CSELFMT2,ENAB)
                                                                      
2016:289:16:34:54.104    8976788  ACISPKT     RS_0000001              
2016:289:16:34:58.104    8976804  ACISPKT     RH_0000001              
2016:289:16:35:21.104    8976893  ACISPKT     RBTXINGALL              
2016:289:17:23:08.325    8988082  MP_OBSID    50616                   
                                                                      
  ==> ObsID change occurs 50.0 minutes after stop science.            
                                                                      
LATEST OCAT INFO FOR OBSID 50616:                                     
No ocat info found for obsid 50616                                    
                                                                      
                                                                      
2016:289:19:14:47.104    9014224  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of  8.20 ks.                              
                                                                      
2016:289:19:17:47.104    9014926  COMMAND_HW  CSELFMT1                
                                                                      
2016:289:19:19:46.104    9015391  COMMAND_SW  OORMPEN                 
                                                                      
  ==> Exit leg pad time is 10.00 ks.                                  
                                                                      
AE-8 EVENTS TIME CHECK:                                               
 from backstop: XE1RADZ0 = 289:16:33:07                               
 from CRM file: XE1RADZ0 = 289:16:33:07                               
                                                                      
 ==> CRM Pad Time: 10 ks and Backstop Pad Time: 10.00 ks agree.       
                                                                      
2016:289:19:19:47.104    9015395  SIMFOCUS     -991                   
                                                                      
2016:289:19:19:47.104    9015395  MP_OBSID    19016                   
                                                                      
  ==> ObsID change occurs 5.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 19016:                                     
No ACIS info found for obsid 19016.                                   
This is an HRC-S observation.                                         
                                                                      
                                                                      
2016:289:19:20:48.004    9015632 AOENDITH  AOENDITH                   
  ==> DITHER ENABLED                                                  
                                                                      
2016:289:19:21:48.004    9015867 AODSDITH  AODSDITH                   
  ==> DITHER DISABLED                                                 
                                                                      
2016:289:19:23:56.004    9016366  ACISPKT     WSVIDALLDN              
2016:289:19:24:14.004    9016436  ACISPKT     WSPOW0CE3E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4 5;  I1 I2 I3 S2 S3            
                                                                      
2016:289:19:25:17.004    9016682  ACISPKT     RS_0000001              
2016:289:19:25:21.004    9016698  ACISPKT     RH_0000001              
2016:289:19:25:44.004    9016788  ACISPKT     WT0023C024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x0023c024                            
   fepCcdSelect               =   10    7    1    2    3    6         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 3 # BEP_TE_MODE_EVHIST                
   recomputeBias              = 1                                     
   trickleBias                = 0                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 32                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 0                                     
   eventAmplitudeRange        = 65535                                 
   windowSlotIndex            = 4                                     
                                                                      
                                                                      
2016:289:19:25:48.004    9016803  ACISPKT     W200039014              
                                                                      
ACIS 2D WINDOW BLOCK LOADS:                                           
   windowSlotIndex            = 4                                     
   windowBlockId              = 0x00039014                            
     ccdId                    = 1                                     
     ccdRow                   = 21                                    
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 199                                   
     sampleCycle              = 1                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
     ccdId                    = 1                                     
     ccdRow                   = 0                                     
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 1023                                  
     sampleCycle              = 0                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
     ccdId                    = 2                                     
     ccdRow                   = 21                                    
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 199                                   
     sampleCycle              = 1                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
     ccdId                    = 2                                     
     ccdRow                   = 0                                     
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 1023                                  
     sampleCycle              = 0                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
     ccdId                    = 3                                     
     ccdRow                   = 21                                    
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 199                                   
     sampleCycle              = 1                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
     ccdId                    = 3                                     
     ccdRow                   = 0                                     
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 1023                                  
     sampleCycle              = 0                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
     ccdId                    = 6                                     
     ccdRow                   = 21                                    
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 199                                   
     sampleCycle              = 1                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
     ccdId                    = 6                                     
     ccdRow                   = 0                                     
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 1023                                  
     sampleCycle              = 0                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
     ccdId                    = 7                                     
     ccdRow                   = 21                                    
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 199                                   
     sampleCycle              = 1                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
     ccdId                    = 7                                     
     ccdRow                   = 0                                     
     ccdColumn                = 0                                     
     width                    = 1023                                  
     height                   = 1023                                  
     sampleCycle              = 0                                     
     lowerEventAmplitude      = 0                                     
     eventAmplitudeRange      = 65535                                 
                                                                      
                                                                      
2016:289:19:25:52.004    9016819  ACISPKT     XTZ0000005              
                                                                      
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-IN,19016,OORMPEN,CSELFMT1,DISA)
                                                                      
2016:289:19:27:48.004    9017271 AOENDITH  AOENDITH                   
  ==> DITHER ENABLED                                                  
                                                                      
                                                                      
2016:289:19:50:01.285 	REAL-TIME COMM BEGINS	2016:289:15:50:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:289:21:15:01.285 	REAL-TIME COMM ENDS	2016:289:17:15:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  85.00 mins.                                     
                                                                      
2016:290:02:20:58.004    9114013  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 24.26 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:290:02:23:58.004    9114715  MP_OBSID    50615                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 50615:                                     
No ocat info found for obsid 50615                                    
                                                                      
                                                                      
2016:290:03:03:09.509    9123892 AOENDITH  AOENDITH                   
  ==> DITHER ENABLED                                                  
                                                                      
2016:290:03:09:49.509    9125453  COMMAND_HW  CSELFMT4                
                                                                      
2016:290:03:09:49.509    9125453  MP_OBSID    19898                   
                                                                      
LATEST OCAT INFO FOR OBSID 19898:                                     
Target Name: G292.0+1.8	SI Mode: TE_00766                             
Instrument: ACIS-I	Grating: NONE	Type: GO                             

Exposure Time: 50	Remaining Exposure time: 0                          
Offset: Y: -0.23	Z: -0.31	Z-sim:                                      
ACIS Exposure Mode: TE	Event TM Format: VF	Frame Time:                
Chips Turned On: YYYY NNNNNN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: Y	Lower: 0.2	Range: 10                                  
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:290:03:09:49.509    9125453  SIMTRANS    92904  (ACIS-I)         
                                                                      
  ==> THERE IS A Z-SIM OF  0.00 mm FOR THIS OBSERVATION.              
                                                                      
                                                                      
2016:290:03:10:01.285 	REAL-TIME COMM BEGINS	2016:289:23:10:01.285  EDT
                                                                      
                                                                      
2016:290:03:10:23.848    9125587  COMMAND_SW  4OLETGRE                
                                                                      
2016:290:03:14:07.309    9126459  COMMAND_HW  CSELFMT2                
                                                                      
2016:290:03:15:49.719    9126859  SIMFOCUS     -486                   
                                                                      
2016:290:03:17:16.219    9127196  SIMFOCUS     -536                   
                                                                      
2016:290:03:24:17.289    9128839  ACISPKT     AA00000000              
                                                                      
2016:290:03:24:21.289    9128855  ACISPKT     AA00000000              
                                                                      
2016:290:03:24:25.289    9128871  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:290:03:24:49.289    9128964  ACISPKT     WSPOW00F1E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4;  I0 I1 I2 I3                 
                                                                      
2016:290:03:25:52.289    9129210  ACISPKT     WT00766024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00766024                            
   fepCcdSelect               =   10    3    2    1    0   10         
   fepMode                    = 3 # FEP_TE_MODE_EV5x5                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 31                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 2500                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:290:03:25:56.289    9129226  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 19898                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00766B is WT00766024 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,19898,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:290:03:26:00.289    9129241  ACISPKT     RS_0000001              
2016:290:03:26:04.289    9129257  ACISPKT     RH_0000001              
                                                                      
2016:290:04:40:01.285 	REAL-TIME COMM ENDS	2016:290:00:40:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:290:09:54:03.289    9220102  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 22.00 ks.                              
                                                                      
 This is 44.00% of the requested time.                                
                                                                      
                                                                      
  ==>ERROR: Scheduled time is less than 90%.                          
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:290:09:57:03.289    9220804  MP_OBSID    50614                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 50614:                                     
No ocat info found for obsid 50614                                    
                                                                      
                                                                      
2016:290:10:30:15.568    9228579  COMMAND_HW  CSELFMT4                
                                                                      
2016:290:10:30:15.568    9228579  MP_OBSID    17738                   
                                                                      
LATEST OCAT INFO FOR OBSID 17738:                                     
Target Name: IC 348	SI Mode: TE_00958                                 
Instrument: ACIS-S	Grating: HETG	Type: GO                             

Exposure Time: 70	Remaining Exposure time: 70                         
Offset: Y: 0	Z: -0.3	Z-sim:                                           
ACIS Exposure Mode: TE	Event TM Format: F	Frame Time:                 
Chips Turned On: NNNN NYYYYN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:290:10:30:15.568    9228579  SIMTRANS    75624  (ACIS-S)         
                                                                      
  ==> THERE IS A Z-SIM OF  0.00 mm FOR THIS OBSERVATION.              
                                                                      
2016:290:10:30:49.907    9228713  COMMAND_SW  4OHETGIN                
                                                                      
2016:290:10:32:14.744    9229044  SIMFOCUS     -418                   
                                                                      
2016:290:10:33:33.504    9229351  SIMFOCUS     -468                   
                                                                      
2016:290:10:34:33.368    9229585  COMMAND_HW  CSELFMT2                
                                                                      
2016:290:10:48:52.622    9232938  ACISPKT     AA00000000              
                                                                      
2016:290:10:48:56.622    9232954  ACISPKT     AA00000000              
                                                                      
2016:290:10:49:00.622    9232969  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:290:10:49:24.622    9233063  ACISPKT     WSPOW1E01E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4;  S1 S2 S3 S4                 
                                                                      
2016:290:10:50:27.622    9233309  ACISPKT     WT00958024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00958024                            
   fepCcdSelect               =   10    7    5    6    8   10         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 31                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:290:10:50:31.622    9233325  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 17738                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00958B is WT00958024 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-IN,LETG-OUT,17738,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:290:10:50:35.622    9233340  ACISPKT     RS_0000001              
2016:290:10:50:39.622    9233356  ACISPKT     RH_0000001              
                                                                      
2016:290:13:30:01.285 	REAL-TIME COMM BEGINS	2016:290:09:30:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:290:15:00:01.285 	REAL-TIME COMM ENDS	2016:290:11:00:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:290:18:11:40.171    9291746  ORBPOINT    EAPOGEE                 
                                                                      
2016:290:21:00:01.285 	REAL-TIME COMM BEGINS	2016:290:17:00:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:290:22:30:01.285 	REAL-TIME COMM ENDS	2016:290:18:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
                                                                      
2016:291:03:40:01.285 	REAL-TIME COMM BEGINS	2016:290:23:40:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:291:05:10:01.285 	REAL-TIME COMM ENDS	2016:291:01:10:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:291:06:37:49.622    9511326  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 70.00 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:291:06:40:49.622    9512029  COMMAND_HW  CSELFMT4                
                                                                      
2016:291:06:40:49.622    9512029  MP_OBSID    18776                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 18776:                                     
Target Name: PLCK G079.95+46.96	SI Mode: TE_0046E                     
Instrument: ACIS-S	Grating: NONE	Type: GO                             

Exposure Time: 10	Remaining Exposure time: 10                         
Offset: Y: -1	Z: 0.5	Z-sim:                                           
ACIS Exposure Mode: TE	Event TM Format: VF	Frame Time:                
Chips Turned On: NNYY NYYYNN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 18	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:291:06:41:23.961    9512163  COMMAND_SW  4OHETGRE                
                                                                      
2016:291:06:45:07.422    9513035  COMMAND_HW  CSELFMT2                
                                                                      
2016:291:06:51:11.267    9514455  ACISPKT     AA00000000              
                                                                      
2016:291:06:51:15.267    9514470  ACISPKT     AA00000000              
                                                                      
2016:291:06:51:19.267    9514486  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:291:06:51:43.267    9514580  ACISPKT     WSPOW0EC3E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4 5;  I2 I3 S1 S2 S3            
                                                                      
2016:291:06:52:46.267    9514826  ACISPKT     WT0046E034              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x0046e034                            
   fepCcdSelect               =   10    7    5    6    3    2         
   fepMode                    = 3 # FEP_TE_MODE_EV5x5                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 31                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:291:06:52:50.267    9514841  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 18776                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_0046EB is WT0046E034 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,18776,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:291:06:52:54.267    9514857  ACISPKT     RS_0000001              
2016:291:06:52:58.267    9514872  ACISPKT     RH_0000001              
2016:291:10:02:08.267    9559165  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 10.00 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:291:10:02:08.267    9559165  SIMTRANS    92904  (ACIS-I)         
                                                                      
  ==> THERE IS A Z-SIM OF  0.00 mm FOR THIS OBSERVATION.              
                                                                      
2016:291:10:04:07.443    9559630  SIMFOCUS     -536                   
                                                                      
2016:291:10:05:08.267    9559868  MP_OBSID    19901                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 19901:                                     
Target Name: ZwCl 0008.8+5215	SI Mode: TE_00458                       
Instrument: ACIS-I	Grating: NONE	Type: GO                             

Exposure Time: 32	Remaining Exposure time: 32                         
Offset: Y: -0.3	Z: -0.3	Z-sim:                                        
ACIS Exposure Mode: TE	Event TM Format: VF	Frame Time:                
Chips Turned On: YYYY NNYNNN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: Y	Lower: 0.1	Range: 13                                  
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:291:10:07:57.155    9560527  ACISPKT     AA00000000              
                                                                      
2016:291:10:08:01.155    9560542  ACISPKT     AA00000000              
                                                                      
2016:291:10:08:05.155    9560558  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:291:10:08:29.155    9560651  ACISPKT     WSPOW04F3E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4 5;  I0 I1 I2 I3 S2            
                                                                      
2016:291:10:09:32.155    9560897  ACISPKT     WT00458034              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00458034                            
   fepCcdSelect               =   10    3    2    1    0    6         
   fepMode                    = 3 # FEP_TE_MODE_EV5x5                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 31                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:291:10:09:36.155    9560913  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 19901                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00458B is WT00458034 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,19901,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:291:10:09:40.155    9560929  ACISPKT     RS_0000001              
2016:291:10:09:44.155    9560944  ACISPKT     RH_0000001              
                                                                      
2016:291:11:00:01.285 	REAL-TIME COMM BEGINS	2016:291:07:00:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:291:12:30:01.285 	REAL-TIME COMM ENDS	2016:291:08:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
                                                                      
2016:291:16:10:01.285 	REAL-TIME COMM BEGINS	2016:291:12:10:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:291:17:40:01.285 	REAL-TIME COMM ENDS	2016:291:13:40:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:291:19:28:44.960    9691835  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 32.19 ks.                              
                                                                      
 This is 100.60% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:291:19:28:44.960    9691835  SIMTRANS   -99616   (HRC-S)         
2016:291:19:31:44.960    9692538  MP_OBSID    50613                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 50613:                                     
No ocat info found for obsid 50613                                    
                                                                      
                                                                      
2016:291:19:34:45.170    9693241  COMMAND_SW  OORMPDS                 
                                                                      
                                                                      
==>The requested SI_MODE for the inbound CTI is TE_007AE              
                                                                      
2016:291:19:34:45.170    9693241  ACISPKT     AA00000000              
                                                                      
2016:291:19:34:49.170    9693256  ACISPKT     AA00000000              
                                                                      
2016:291:19:34:53.170    9693272  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:291:19:35:17.170    9693366  ACISPKT     WSPOW3F03F              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps; std S array                      
                                                                      
2016:291:19:36:20.170    9693612  ACISPKT     WBTX_QUIET              
2016:291:19:36:24.170    9693627  ACISPKT     WT007AE024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x007ae024                            
   fepCcdSelect               =    9    7    5    6    4    8         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 32                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3750                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:291:19:36:28.170    9693643  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 50613                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_007AEB is WT007AE024 and is stored.
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-OUT,50613,OORMPDS,CSELFMT2,ENAB)
                                                                      
2016:291:19:36:32.170    9693658  ACISPKT     RS_0000001              
2016:291:19:36:36.170    9693674  ACISPKT     RH_0000001              
2016:291:19:36:59.170    9693764  ACISPKT     RBTXINGALL              
2016:291:19:38:28.016    9694110  MP_OBSID    50612                   
                                                                      
  ==> ObsID change occurs 3.6 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 50612:                                     
No ocat info found for obsid 50612                                    
                                                                      
                                                                      
2016:291:20:55:05.170    9712051  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of  3.32 ks.                              
                                                                      
2016:291:20:58:05.170    9712753  ACISPKT     AA00000000              
                                                                      
2016:291:20:58:05.170    9712753  ORBPOINT    EEF1000                 
                                                                      
  ==> Entry leg pad time is  5.00 ks.                                 
                                                                      
AE-8 EVENTS TIME CHECK:                                               
 from backstop: EE1RADZ0 = 291:20:58:05                               
 from CRM file: EE1RADZ0 = 291:20:58:05                               
                                                                      
 ==> CRM Pad Time: 5 ks and Backstop Pad Time:  5.00 ks agree.        
                                                                      
2016:291:20:58:14.170    9712788  ACISPKT     WSVIDALLDN              
2016:291:20:59:17.170    9713034  ACISPKT     RS_0000001              
2016:291:22:44:54.672    9737766  MP_OBSID    50611                   
                                                                      
LATEST OCAT INFO FOR OBSID 50611:                                     
No ocat info found for obsid 50611                                    
                                                                      
                                                                      
2016:292:01:55:26.293    9741725  ORBPOINT   EPERIGEE                 
                                                                      
2016:292:03:20:01.285 	REAL-TIME COMM BEGINS	2016:291:23:20:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:292:04:50:01.285 	REAL-TIME COMM ENDS	2016:292:00:50:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:292:07:25:12.784    9859592  MP_OBSID    50610                   
                                                                      
LATEST OCAT INFO FOR OBSID 50610:                                     
No ocat info found for obsid 50610                                    
                                                                      
                                                                      
2016:292:08:06:05.170    9869163  ACISPKT     AA00000000              
                                                                      
2016:292:08:06:05.170    9869163  ORBPOINT    XEF1000                 
                                                                      
==> The requested SI_MODE for the outbound CTI is TE_00B26            
                                                                      
2016:292:08:06:09.170    9869178  ACISPKT     AA00000000              
                                                                      
2016:292:08:06:13.170    9869194  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:292:08:06:37.170    9869288  ACISPKT     WSPOW0AF3F              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps;  I0 I1 I2 I3 S1 S3               
                                                                      
2016:292:08:07:40.170    9869533  ACISPKT     WBTX_QUIET              
2016:292:08:07:44.170    9869549  ACISPKT     WT00B26014              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00b26014                            
   fepCcdSelect               =    3    7    0    1    2    5         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 32                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3750                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:292:08:07:48.170    9869565  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 50610                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00B26B is WT00B26014 and is stored.
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-OUT,50610,OORMPDS,CSELFMT2,ENAB)
                                                                      
2016:292:08:07:52.170    9869580  ACISPKT     RS_0000001              
2016:292:08:07:56.170    9869596  ACISPKT     RH_0000001              
2016:292:08:08:19.170    9869686  ACISPKT     RBTXINGALL              
2016:292:10:52:44.170    9908183  COMMAND_SW  OORMPEN                 
                                                                      
  ==> Exit leg pad time is 10.00 ks.                                  
                                                                      
AE-8 EVENTS TIME CHECK:                                               
 from backstop: XE1RADZ0 = 292:08:06:05                               
 from CRM file: XE1RADZ0 = 292:08:06:05                               
                                                                      
 ==> CRM Pad Time: 10 ks and Backstop Pad Time: 10.00 ks agree.       
                                                                      
2016:292:10:52:45.170    9908187  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of  8.50 ks.                              
                                                                      
2016:292:10:52:45.170    9908187  SIMTRANS    92904  (ACIS-I)         
                                                                      
  ==> THERE IS A Z-SIM OF  0.00 mm FOR THIS OBSERVATION.              
                                                                      
2016:292:10:52:46.170    9908191  ACISPKT     AA00000000              
                                                                      
2016:292:10:52:50.170    9908207  ACISPKT     AA00000000              
                                                                      
2016:292:10:52:54.170    9908222  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:292:10:53:18.170    9908316  ACISPKT     WSPOW00F1E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4;  I0 I1 I2 I3                 
                                                                      
2016:292:10:54:21.170    9908562  ACISPKT     WT00766024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00766024                            
   fepCcdSelect               =   10    3    2    1    0   10         
   fepMode                    = 3 # FEP_TE_MODE_EV5x5                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 31                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 2500                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:292:10:54:25.170    9908577  ACISPKT     XTZ0000005              
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,50610,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:292:10:54:29.170    9908593  ACISPKT     RS_0000001              
2016:292:10:54:33.170    9908609  ACISPKT     RH_0000001              
2016:292:10:55:45.170    9908890  MP_OBSID    19899                   
                                                                      
  ==> ObsID change occurs 2.9 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 19899:                                     
Target Name: G292.0+1.8	SI Mode: TE_00766                             
Instrument: ACIS-I	Grating: NONE	Type: GO                             
Exposure Time: 43	Remaining Exposure time: 43                         
Offset: Y: -0.23	Z: -0.31	Z-sim:                                      
ACIS Exposure Mode: TE	Event TM Format: VF	Frame Time:                
Chips Turned On: YYYY NNNNNN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: Y	Lower: 0.2	Range: 10                                  
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
---------------------------------------------------------------------------
 Parameter block and set up check for 19899                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00766B is WT00766024 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
2016:292:12:15:01.285 	REAL-TIME COMM BEGINS	2016:292:08:15:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:292:13:30:01.285 	REAL-TIME COMM ENDS	2016:292:09:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  75.00 mins.                                     
                                                                      
                                                                      
2016:292:22:00:01.285 	REAL-TIME COMM BEGINS	2016:292:18:00:01.285  EDT
                                                                      
                                                                      
2016:292:23:12:32.170   10081405  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 43.00 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:292:23:15:32.170   10082107  MP_OBSID    50609                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 50609:                                     
No ocat info found for obsid 50609                                    
                                                                      
                                                                      
                                                                      
2016:292:23:30:01.285 	REAL-TIME COMM ENDS	2016:292:19:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:292:23:47:23.684   10089567  MP_OBSID    19902                   
                                                                      
LATEST OCAT INFO FOR OBSID 19902:                                     
Target Name: ZwCl 0008.8+5215	SI Mode: TE_00458                       
Instrument: ACIS-I	Grating: NONE	Type: GO                             
Exposure Time: 65	Remaining Exposure time: 65                         
Offset: Y: -0.3	Z: -0.3	Z-sim:                                        
ACIS Exposure Mode: TE	Event TM Format: VF	Frame Time:                
Chips Turned On: YYYY NNYNNN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: Y	Lower: 0.1	Range: 13                                  
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:293:00:14:44.583   10095970  ACISPKT     AA00000000              
                                                                      
2016:293:00:14:48.583   10095986  ACISPKT     AA00000000              
                                                                      
2016:293:00:14:52.583   10096001  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:293:00:15:16.583   10096095  ACISPKT     WSPOW04F3E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4 5;  I0 I1 I2 I3 S2            
                                                                      
2016:293:00:16:19.583   10096341  ACISPKT     WT00458034              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00458034                            
   fepCcdSelect               =   10    3    2    1    0    6         
   fepMode                    = 3 # FEP_TE_MODE_EV5x5                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 31                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:293:00:16:23.583   10096357  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 19902                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00458B is WT00458034 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,19902,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:293:00:16:27.583   10096372  ACISPKT     RS_0000001              
2016:293:00:16:31.583   10096388  ACISPKT     RH_0000001              
                                                                      
2016:293:03:45:01.285 	REAL-TIME COMM BEGINS	2016:292:23:45:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:293:05:15:01.285 	REAL-TIME COMM ENDS	2016:293:01:15:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:293:09:38:46.018   10228034  ORBPOINT    EAPOGEE                 
                                                                      
2016:293:11:15:01.285 	REAL-TIME COMM BEGINS	2016:293:07:15:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:293:12:45:01.285 	REAL-TIME COMM ENDS	2016:293:08:45:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:293:19:07:21.583   10361168  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 66.50 ks.                              
                                                                      
 This is 102.31% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:293:19:07:21.583   10361168  SIMTRANS    75624  (ACIS-S)         
                                                                      
  ==> THERE IS A Z-SIM OF  0.00 mm FOR THIS OBSERVATION.              
                                                                      
2016:293:19:09:20.759   10361633  SIMFOCUS     -418                   
                                                                      
2016:293:19:10:21.583   10361871  COMMAND_HW  CSELFMT4                
                                                                      
2016:293:19:10:21.583   10361871  MP_OBSID    17793                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 17793:                                     
Target Name: GRS 1739-278	SI Mode: TE_00928                           
Instrument: ACIS-S	Grating: HETG	Type: TOO                            

Exposure Time: 30	Remaining Exposure time: 30                         
Offset: Y: 0	Z: -0.3	Z-sim:                                           
ACIS Exposure Mode: TE	Event TM Format: G	Frame Time:                 
Chips Turned On: NNNN YYYYYY                                          
Subarray Type: CUSTOM	Start: 257	Rows: 512	Frame Time:                
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:293:19:10:39.519   10361941  SIMFOCUS     -468                   
                                                                      
2016:293:19:10:55.922   10362005  COMMAND_SW  4OHETGIN                
                                                                      
2016:293:19:14:39.383   10362877  COMMAND_HW  CSELFMT2                
                                                                      
2016:293:19:29:29.822   10366352  ACISPKT     AA00000000              
                                                                      
2016:293:19:29:33.822   10366367  ACISPKT     AA00000000              
                                                                      
2016:293:19:29:37.822   10366383  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:293:19:30:01.822   10366476  ACISPKT     WSPOW3F03F              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps; std S array                      
                                                                      
2016:293:19:31:04.822   10366722  ACISPKT     WT00928024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00928024                            
   fepCcdSelect               =    4    7    5    6    8    9         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 2 # BEP_TE_MODE_GRADED                
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 256                                   
   subarrayRowCount           = 511                                   
   primaryExposure            = 18                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:293:19:31:08.822   10366738  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 17793                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00928B is WT00928024 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-IN,LETG-OUT,17793,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:293:19:31:12.822   10366754  ACISPKT     RS_0000001              
2016:293:19:31:16.822   10366769  ACISPKT     RH_0000001              
                                                                      
2016:293:22:00:01.285 	REAL-TIME COMM BEGINS	2016:293:18:00:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:293:23:30:01.285 	REAL-TIME COMM ENDS	2016:293:19:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
                                                                      
2016:294:04:00:01.285 	REAL-TIME COMM BEGINS	2016:294:00:00:01.285  EDT
                                                                      
                                                                      
2016:294:04:09:04.822   10488010  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 30.00 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:294:04:12:04.822   10488713  COMMAND_HW  CSELFMT4                
                                                                      
2016:294:04:12:04.822   10488713  MP_OBSID    19903                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 19903:                                     
Target Name: Cassiopeia A	SI Mode: TE_00CC0                           
Instrument: ACIS-S	Grating: NONE	Type: GO                             

Exposure Time: 24	Remaining Exposure time: 24                         
Offset: Y: -2.25	Z: -1	Z-sim:                                         
ACIS Exposure Mode: TE	Event TM Format: G	Frame Time:                 
Chips Turned On: NNNN NNNYYN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:294:04:12:39.161   10488847  COMMAND_SW  4OHETGRE                
                                                                      
2016:294:04:16:22.622   10489719  COMMAND_HW  CSELFMT2                
                                                                      
2016:294:04:31:21.812   10493228  ACISPKT     AA00000000              
                                                                      
2016:294:04:31:25.812   10493243  ACISPKT     AA00000000              
                                                                      
2016:294:04:31:29.812   10493259  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:294:04:31:53.812   10493353  ACISPKT     WSPOW18006              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2;  S3 S4                           
                                                                      
2016:294:04:32:56.812   10493598  ACISPKT     WT00CC0014              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00cc0014                            
   fepCcdSelect               =   10    7    8   10   10   10         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 2 # BEP_TE_MODE_GRADED                
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 30                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:294:04:33:00.812   10493614  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 19903                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00CC0B is WT00CC0014 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,19903,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:294:04:33:04.812   10493630  ACISPKT     RS_0000001              
2016:294:04:33:08.812   10493645  ACISPKT     RH_0000001              
                                                                      
2016:294:05:30:01.285 	REAL-TIME COMM ENDS	2016:294:01:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:294:11:44:19.140   10594603  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 24.88 ks.                              
                                                                      
 This is 103.67% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:294:11:44:19.140   10594603  SIMTRANS   -99616   (HRC-S)         
2016:294:11:47:19.140   10595305  MP_OBSID    50608                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 50608:                                     
No ocat info found for obsid 50608                                    
                                                                      
                                                                      
2016:294:11:49:55.574   10595915  COMMAND_SW  OORMPDS                 
                                                                      
                                                                      
==>The requested SI_MODE for the inbound CTI is TE_007AC              
                                                                      
2016:294:11:49:55.574   10595915  ACISPKT     AA00000000              
                                                                      
2016:294:11:49:59.574   10595931  ACISPKT     AA00000000              
                                                                      
2016:294:11:50:03.574   10595947  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:294:11:50:27.574   10596040  ACISPKT     WSPOW0CF3F              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps; std I array                      
                                                                      
2016:294:11:51:30.574   10596286  ACISPKT     WBTX_QUIET              
2016:294:11:51:34.574   10596302  ACISPKT     WT007AC024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x007ac024                            
   fepCcdSelect               =    3    7    0    1    2    6         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 32                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3750                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:294:11:51:38.574   10596317  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 50608                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_007ACB is WT007AC024 and is stored.
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-OUT,50608,OORMPDS,CSELFMT2,ENAB)
                                                                      
2016:294:11:51:42.574   10596333  ACISPKT     RS_0000001              
2016:294:11:51:46.574   10596349  ACISPKT     RH_0000001              
2016:294:11:52:09.574   10596438  ACISPKT     RBTXINGALL              
2016:294:12:03:36.556   10599119  MP_OBSID    50607                   
                                                                      
  ==> ObsID change occurs 13.6 minutes after stop science.            
                                                                      
LATEST OCAT INFO FOR OBSID 50607:                                     
No ocat info found for obsid 50607                                    
                                                                      
                                                                      
                                                                      
2016:294:12:30:01.285 	REAL-TIME COMM BEGINS	2016:294:08:30:01.285  EDT
                                                                      
                                                                      
2016:294:13:10:15.574   10614725  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of  3.32 ks.                              
                                                                      
2016:294:13:13:15.574   10615428  ACISPKT     AA00000000              
                                                                      
2016:294:13:13:15.574   10615428  ORBPOINT    EEF1000                 
                                                                      
  ==> Entry leg pad time is  5.00 ks.                                 
                                                                      
AE-8 EVENTS TIME CHECK:                                               
 from backstop: EE1RADZ0 = 294:13:13:15                               
 from CRM file: EE1RADZ0 = 294:13:13:15                               
                                                                      
 ==> CRM Pad Time: 5 ks and Backstop Pad Time:  5.00 ks agree.        
                                                                      
2016:294:13:13:24.574   10615463  ACISPKT     WSVIDALLDN              
2016:294:13:14:27.574   10615709  ACISPKT     RS_0000001              
                                                                      
2016:294:14:00:01.285 	REAL-TIME COMM ENDS	2016:294:10:00:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
                                                                      
2016:294:15:20:01.542 	REAL-TIME COMM BEGINS	2016:294:11:20:01.542  EDT
                                                                      
                                                                      
2016:294:16:03:04.136   10655188  MP_OBSID    50606                   
                                                                      
LATEST OCAT INFO FOR OBSID 50606:                                     
No ocat info found for obsid 50606                                    
                                                                      
                                                                      
2016:294:16:36:46.000   10663078  COMMAND_HW  CSELFMT6                
                                                                      
2016:294:16:41:13.000   10664120  COMMAND_HW  CSELFMT2                
                                                                      
2016:294:17:22:45.933   10664126  ORBPOINT   EPERIGEE                 
                                                                      
2016:294:18:00:01.542 	REAL-TIME COMM ENDS	2016:294:14:00:01.542  EDT 
                                                                      
                                                                      
  ==> COMM DURATION: 160.00 mins.                                     
                                                                      
                                                                      
2016:294:20:55:01.285 	REAL-TIME COMM BEGINS	2016:294:16:55:01.285  EDT
                                                                      
                                                                      
2016:294:22:02:43.005   10739398  MP_OBSID    50605                   
                                                                      
LATEST OCAT INFO FOR OBSID 50605:                                     
No ocat info found for obsid 50605                                    
                                                                      
                                                                      
                                                                      
2016:294:22:25:01.285 	REAL-TIME COMM ENDS	2016:294:18:25:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:294:22:47:15.574   10749828  ACISPKT     AA00000000              
                                                                      
2016:294:22:47:15.574   10749828  ORBPOINT    XEF1000                 
                                                                      
==> The requested SI_MODE for the outbound CTI is TE_007AE            
                                                                      
2016:294:22:47:19.574   10749843  ACISPKT     AA00000000              
                                                                      
2016:294:22:47:23.574   10749859  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:294:22:47:47.574   10749953  ACISPKT     WSPOW3F03F              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps; std S array                      
                                                                      
2016:294:22:48:50.574   10750198  ACISPKT     WBTX_QUIET              
2016:294:22:48:54.574   10750214  ACISPKT     WT007AE024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x007ae024                            
   fepCcdSelect               =    9    7    5    6    4    8         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 32                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3750                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:294:22:48:58.574   10750230  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 50605                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_007AEB is WT007AE024 and is stored.
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-OUT,50605,OORMPDS,CSELFMT2,ENAB)
                                                                      
2016:294:22:49:02.574   10750245  ACISPKT     RS_0000001              
2016:294:22:49:06.574   10750261  ACISPKT     RH_0000001              
2016:294:22:49:29.574   10750351  ACISPKT     RBTXINGALL              
2016:295:01:08:53.856   10782992  COMMAND_HW  CSELFMT4                
                                                                      
>>>ERROR: CHANGE FROM FMT2 OCCURS BEFORE A STOP SCIENCE!              
                                                                      
2016:295:01:09:28.195   10783126  COMMAND_SW  4OHETGIN                
                                                                      
2016:295:01:13:11.656   10783998  COMMAND_HW  CSELFMT2                
                                                                      
2016:295:01:30:55.574   10788150  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of  1.29 ks.                              
                                                                      
2016:295:01:33:54.574   10788848  COMMAND_SW  OORMPEN                 
                                                                      
  ==> Exit leg pad time is 10.00 ks.                                  
                                                                      
AE-8 EVENTS TIME CHECK:                                               
 from backstop: XE1RADZ0 = 294:22:47:15                               
 from CRM file: XE1RADZ0 = 294:22:47:15                               
                                                                      
 ==> CRM Pad Time: 10 ks and Backstop Pad Time: 10.00 ks agree.       
                                                                      
2016:295:01:33:55.574   10788852  MP_OBSID    19904                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 19904:                                     
Target Name: 4U 1630-47	SI Mode: CC_00162                             
Instrument: ACIS-S	Grating: HETG	Type: DDT                            

Exposure Time: 30	Remaining Exposure time: 30                         
Offset: Y: 0	Z: -0.3	Z-sim: -6.14

ACIS Exposure Mode: CC	Event TM Format: G	Frame Time:                 
Chips Turned On: NNNN NYYYYY                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: Y	Lower: 0.3	Range: 10                                  
Window Filter: Y	Start Row: 1	Start Column: 172                       
Height: 1024	Width: 100                                               
Lower Energy: 0.3	Energy Range: 10	Sample Rate: 20                    
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
LATEST OCAT WINDOW INFO FOR OBSID 19904:                              
Window on CCD: 7	Start Row: 1	Start Column: 172                       
Height: 1024	Width: 100	Include: E                                    
Lower Energy: 0.3	Energy Range: 10	Sample Rate: 20                    
2016:295:01:33:55.574   10788852  SIMTRANS    73176  (ACIS-S)         
                                                                      
  ==> THERE IS A Z-SIM OF -6.16 mm FOR THIS OBSERVATION.              
                                                                      
2016:295:01:35:02.649   10789114  ACISPKT     AA00000000              
                                                                      
2016:295:01:35:06.649   10789129  ACISPKT     AA00000000              
                                                                      
2016:295:01:35:10.649   10789145  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:295:01:35:34.649   10789239  ACISPKT     WSPOW3E03E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4 5;  S1 S2 S3 S4 S5            
                                                                      
2016:295:01:36:37.649   10789485  ACISPKT     WC00162014              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00162014                            
   fepCcdSelect               =   10    7    5    6    8    9         
   fepMode                    = 2 # FEP_CC_MODE_EV3x3                 
   bepPackingMode             = 1 # BEP_CC_MODE_GRADED                
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   rowSum                     = 0                                     
   columnSum                  = 0                                     
   fep0SplitThreshold         =    0    0    0    0                   
   fep1SplitThreshold         =   13   13   13   13                   
   fep2SplitThreshold         =   13   13   13   13                   
   fep3SplitThreshold         =   16   16   16   16                   
   fep4SplitThreshold         =   16   16   16   16                   
   fep5SplitThreshold         =   16   16   16   16                   
   lowerEventAmplitude        = 31                                    
   eventAmplitudeRange        = 2500                                  
   windowSlotIndex            = 4                                     
                                                                      
                                                                      
2016:295:01:36:41.649   10789500  ACISPKT     W1000C4014              
                                                                      
ACIS 1D WINDOW BLOCK LOADS:                                           
   windowSlotIndex            = 4                                     
   windowBlockId              = 0x000c4014                            
     ccdId                    = 7                                     
     ccdColumn                = 171                                   
     width                    = 99                                    
     sampleCycle              = 20                                    
     lowerEventAmplitude      = 31                                    
     eventAmplitudeRange      = 2500                                  
                                                                      
                                                                      
2016:295:01:36:45.649   10789516  ACISPKT     XCZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 19904                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode CC_00162B is WC00162014 and is stored.
                                                                      
                                                                      
  ==> Window for SI mode CC_00162 is W1000C4014 and is stored.        
  ==> The Window Block and Window OCAT agree for this observation     
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-IN,LETG-OUT,19904,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:295:01:36:49.649   10789531  ACISPKT     RS_0000001              
2016:295:01:36:53.649   10789547  ACISPKT     RH_0000001              
                                                                      
2016:295:02:50:01.285 	REAL-TIME COMM BEGINS	2016:294:22:50:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:295:04:20:01.285 	REAL-TIME COMM ENDS	2016:295:00:20:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:295:10:20:38.649   10912181  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 31.00 ks.                              
                                                                      
 This is 103.32% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:295:10:20:38.649   10912181  SIMTRANS    75624  (ACIS-S)         
                                                                      
  ==> THERE IS A Z-SIM OF  0.00 mm FOR THIS OBSERVATION.              
                                                                      
2016:295:10:23:38.649   10912884  COMMAND_HW  CSELFMT4                
                                                                      
2016:295:10:23:38.649   10912884  MP_OBSID    17785                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 17785:                                     
Target Name: PSR J1023+0038	SI Mode: CC_00112                         
Instrument: ACIS-S	Grating: NONE	Type: GO                             

Exposure Time: 20	Remaining Exposure time: 20                         
Offset: Y: 0	Z: -0.3	Z-sim:                                           
ACIS Exposure Mode: CC	Event TM Format: G	Frame Time:                 
Chips Turned On: NNNN NNNYNN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:295:10:24:12.988   10913018  COMMAND_SW  4OHETGRE                
                                                                      
2016:295:10:27:56.449   10913890  COMMAND_HW  CSELFMT2                
                                                                      
2016:295:10:57:23.666   10920786  ACISPKT     AA00000000              
                                                                      
2016:295:10:57:27.666   10920802  ACISPKT     AA00000000              
                                                                      
2016:295:10:57:31.666   10920817  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:295:10:57:55.666   10920911  ACISPKT     WSPOW08002              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1;  S3                                
                                                                      
2016:295:10:58:58.666   10921157  ACISPKT     WC00112014              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00112014                            
   fepCcdSelect               =   10    7   10   10   10   10         
   fepMode                    = 2 # FEP_CC_MODE_EV3x3                 
   bepPackingMode             = 1 # BEP_CC_MODE_GRADED                
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   rowSum                     = 0                                     
   columnSum                  = 0                                     
   fep0SplitThreshold         =    0    0    0    0                   
   fep1SplitThreshold         =   13   13   13   13                   
   fep2SplitThreshold         =    0    0    0    0                   
   fep3SplitThreshold         =    0    0    0    0                   
   fep4SplitThreshold         =    0    0    0    0                   
   fep5SplitThreshold         =    0    0    0    0                   
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:295:10:59:02.666   10921172  ACISPKT     XCZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 17785                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode CC_00112B is WC00112014 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,17785,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:295:10:59:06.666   10921188  ACISPKT     RS_0000001              
2016:295:10:59:10.666   10921204  ACISPKT     RH_0000001              
                                                                      
2016:295:11:25:01.285 	REAL-TIME COMM BEGINS	2016:295:07:25:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:295:12:55:01.285 	REAL-TIME COMM ENDS	2016:295:08:55:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:295:16:39:39.666   11000927  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 20.00 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:295:16:42:39.666   11001629  MP_OBSID    18344                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 18344:                                     
Target Name: Cassiopeia A	SI Mode: TE_00CC0                           
Instrument: ACIS-S	Grating: NONE	Type: GO                             
Exposure Time: 26	Remaining Exposure time: 26                         
Offset: Y: -2.25	Z: -1	Z-sim:                                         
ACIS Exposure Mode: TE	Event TM Format: G	Frame Time:                 
Chips Turned On: NNNN NNNYYN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:295:17:03:34.127   11006524  ACISPKT     AA00000000              
                                                                      
2016:295:17:03:38.127   11006540  ACISPKT     AA00000000              
                                                                      
2016:295:17:03:42.127   11006556  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:295:17:04:06.127   11006649  ACISPKT     WSPOW18006              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2;  S3 S4                           
                                                                      
2016:295:17:05:09.127   11006895  ACISPKT     WT00CC0014              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00cc0014                            
   fepCcdSelect               =   10    7    8   10   10   10         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 2 # BEP_TE_MODE_GRADED                
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 30                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:295:17:05:13.127   11006911  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 18344                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00CC0B is WT00CC0014 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,18344,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:295:17:05:17.127   11006926  ACISPKT     RS_0000001              
2016:295:17:05:21.127   11006942  ACISPKT     RH_0000001              
                                                                      
2016:295:22:00:01.285 	REAL-TIME COMM BEGINS	2016:295:18:00:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:295:23:30:01.285 	REAL-TIME COMM ENDS	2016:295:19:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:296:00:35:10.127   11112265  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 26.00 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:296:00:35:10.127   11112265  SIMTRANS    92904  (ACIS-I)         
                                                                      
  ==> THERE IS A Z-SIM OF  0.00 mm FOR THIS OBSERVATION.              
                                                                      
2016:296:00:37:09.303   11112730  SIMFOCUS     -536                   
                                                                      
2016:296:00:38:10.127   11112967  MP_OBSID    18244                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 18244:                                     
Target Name: ZwCl 0008.8+5215	SI Mode: TE_00458                       
Instrument: ACIS-I	Grating: NONE	Type: GO                             

Exposure Time: 31	Remaining Exposure time: 31                         
Offset: Y: -0.3	Z: -0.3	Z-sim:                                        
ACIS Exposure Mode: TE	Event TM Format: VF	Frame Time:                
Chips Turned On: YYYY NNYNNN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: Y	Lower: 0.1	Range: 13                                  
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:296:00:38:10.127   11112967  ACISPKT     AA00000000              
                                                                      
2016:296:00:38:14.127   11112983  ACISPKT     AA00000000              
                                                                      
2016:296:00:38:18.127   11112999  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:296:00:38:42.127   11113092  ACISPKT     WSPOW04F3E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4 5;  I0 I1 I2 I3 S2            
                                                                      
2016:296:00:39:45.127   11113338  ACISPKT     WT00458034              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00458034                            
   fepCcdSelect               =   10    3    2    1    0    6         
   fepMode                    = 3 # FEP_TE_MODE_EV5x5                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 31                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:296:00:39:49.127   11113354  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 18244                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00458B is WT00458034 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,18244,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:296:00:39:53.127   11113369  ACISPKT     RS_0000001              
2016:296:00:39:57.127   11113385  ACISPKT     RH_0000001              
2016:296:01:06:32.243   11116703  ORBPOINT    EAPOGEE                 
                                                                      
2016:296:04:00:01.285 	REAL-TIME COMM BEGINS	2016:296:00:00:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:296:05:30:01.285 	REAL-TIME COMM ENDS	2016:296:01:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:296:09:55:47.127   11243531  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 32.00 ks.                              
                                                                      
 This is 103.23% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:296:09:55:47.127   11243531  SIMTRANS    75624  (ACIS-S)         
                                                                      
  ==> THERE IS A Z-SIM OF  0.00 mm FOR THIS OBSERVATION.              
                                                                      
2016:296:09:57:46.303   11243996  SIMFOCUS     -418                   
                                                                      
2016:296:09:58:47.127   11244234  COMMAND_HW  CSELFMT4                
                                                                      
2016:296:09:58:47.127   11244234  MP_OBSID    19900                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 19900:                                     
Target Name: IC 348	SI Mode: TE_00958                                 
Instrument: ACIS-S	Grating: HETG	Type: GO                             

Exposure Time: 20	Remaining Exposure time: 20                         
Offset: Y: 0	Z: -0.3	Z-sim:                                           
ACIS Exposure Mode: TE	Event TM Format: F	Frame Time:                 
Chips Turned On: NNNN NYYYYN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:296:09:59:05.063   11244304  SIMFOCUS     -468                   
                                                                      
2016:296:09:59:21.466   11244368  COMMAND_SW  4OHETGIN                
                                                                      
2016:296:10:03:04.927   11245240  COMMAND_HW  CSELFMT2                
                                                                      
2016:296:10:03:54.054   11245431  ACISPKT     AA00000000              
                                                                      
2016:296:10:03:58.054   11245447  ACISPKT     AA00000000              
                                                                      
2016:296:10:04:02.054   11245463  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:296:10:04:26.054   11245556  ACISPKT     WSPOW1E01E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4;  S1 S2 S3 S4                 
                                                                      
2016:296:10:05:29.054   11245802  ACISPKT     WT00958024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00958024                            
   fepCcdSelect               =   10    7    5    6    8   10         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 31                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:296:10:05:33.054   11245818  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 19900                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00958B is WT00958024 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-IN,LETG-OUT,19900,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:296:10:05:37.054   11245833  ACISPKT     RS_0000001              
2016:296:10:05:41.054   11245849  ACISPKT     RH_0000001              
                                                                      
2016:296:11:45:01.285 	REAL-TIME COMM BEGINS	2016:296:07:45:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:296:13:15:01.285 	REAL-TIME COMM ENDS	2016:296:09:15:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:296:15:59:31.054   11328698  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 20.00 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:296:16:02:31.054   11329400  COMMAND_HW  CSELFMT4                
                                                                      
2016:296:16:02:31.054   11329400  MP_OBSID    19891                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 19891:                                     
Target Name: CXOU J103844.8+533003	SI Mode: TE_007E2                  
Instrument: ACIS-S	Grating: NONE	Type: DDT                            

Exposure Time: 35	Remaining Exposure time: 35                         
Offset: Y: 0	Z: 0	Z-sim:                                              
ACIS Exposure Mode: TE	Event TM Format: F	Frame Time:                 
Chips Turned On: NNYY NYYYYN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:296:16:03:05.393   11329534  COMMAND_SW  4OHETGRE                
                                                                      
2016:296:16:06:48.854   11330406  COMMAND_HW  CSELFMT2                
                                                                      
2016:296:16:07:21.654   11330534  ACISPKT     AA00000000              
                                                                      
2016:296:16:07:25.654   11330550  ACISPKT     AA00000000              
                                                                      
2016:296:16:07:29.654   11330566  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:296:16:07:53.654   11330659  ACISPKT     WSPOW1EC3F              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps;  I2 I3 S1 S2 S3 S4               
                                                                      
2016:296:16:08:56.654   11330905  ACISPKT     WT007E2024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x007e2024                            
   fepCcdSelect               =    2    7    5    6    3    8         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 32                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:296:16:09:00.654   11330921  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 19891                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_007E2B is WT007E2024 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,19891,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:296:16:09:04.654   11330936  ACISPKT     RS_0000001              
2016:296:16:09:08.654   11330952  ACISPKT     RH_0000001              
                                                                      
2016:296:22:05:01.285 	REAL-TIME COMM BEGINS	2016:296:18:05:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:296:23:35:01.285 	REAL-TIME COMM ENDS	2016:296:19:35:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:297:02:38:31.563   11478319  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 36.37 ks.                              
                                                                      
 This is 103.91% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:297:02:38:31.563   11478319  SIMTRANS   -99616   (HRC-S)         
2016:297:02:41:31.563   11479022  MP_OBSID    50604                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 50604:                                     
No ocat info found for obsid 50604                                    
                                                                      
                                                                      
2016:297:02:44:07.997   11479632  COMMAND_SW  OORMPDS                 
                                                                      
                                                                      
==>The requested SI_MODE for the inbound CTI is TE_00B26              
                                                                      
2016:297:02:44:07.997   11479632  ACISPKT     AA00000000              
                                                                      
2016:297:02:44:11.997   11479648  ACISPKT     AA00000000              
                                                                      
2016:297:02:44:15.997   11479663  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:297:02:44:39.997   11479757  ACISPKT     WSPOW0AF3F              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps;  I0 I1 I2 I3 S1 S3               
                                                                      
2016:297:02:45:42.997   11480003  ACISPKT     WBTX_QUIET              
2016:297:02:45:46.997   11480019  ACISPKT     WT00B26014              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00b26014                            
   fepCcdSelect               =    3    7    0    1    2    5         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 32                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3750                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:297:02:45:50.997   11480034  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 50604                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00B26B is WT00B26014 and is stored.
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-OUT,50604,OORMPDS,CSELFMT2,ENAB)
                                                                      
2016:297:02:45:54.997   11480050  ACISPKT     RS_0000001              
2016:297:02:45:58.997   11480065  ACISPKT     RH_0000001              
2016:297:02:46:21.997   11480155  ACISPKT     RBTXINGALL              
2016:297:02:58:27.843   11482988  MP_OBSID    50603                   
                                                                      
  ==> ObsID change occurs 14.3 minutes after stop science.            
                                                                      
LATEST OCAT INFO FOR OBSID 50603:                                     
No ocat info found for obsid 50603                                    
                                                                      
                                                                      
                                                                      
2016:297:04:00:01.285 	REAL-TIME COMM BEGINS	2016:297:00:00:01.285  EDT
                                                                      
                                                                      
2016:297:04:13:21.997   11500526  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of  3.85 ks.                              
                                                                      
2016:297:04:16:21.997   11501228  ACISPKT     AA00000000              
                                                                      
2016:297:04:16:21.997   11501228  ORBPOINT    EEF1000                 
                                                                      
  ==> Entry leg pad time is  5.53 ks.                                 
                                                                      
AE-8 EVENTS TIME CHECK:                                               
 from backstop: EE1RADZ0 = 297:04:16:21                               
 from CRM file: EE1RADZ0 = 297:04:16:21                               
                                                                      
 ==> CRM Pad Time: 5.534 ks and Backstop Pad Time:  5.53 ks agree.    
                                                                      
2016:297:04:16:30.997   11501263  ACISPKT     WSVIDALLDN              
2016:297:04:17:33.997   11501509  ACISPKT     RS_0000001              
                                                                      
2016:297:05:30:01.285 	REAL-TIME COMM ENDS	2016:297:01:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:297:08:32:57.801   11561309  MP_OBSID    50602                   
                                                                      
LATEST OCAT INFO FOR OBSID 50602:                                     
No ocat info found for obsid 50602                                    
                                                                      
                                                                      
2016:297:08:50:12.788   11563787  ORBPOINT   EPERIGEE                 
                                                                      
2016:297:11:15:01.285 	REAL-TIME COMM BEGINS	2016:297:07:15:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:297:12:45:01.285 	REAL-TIME COMM ENDS	2016:297:08:45:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:297:14:34:20.107   11645923  MP_OBSID    50601                   
                                                                      
LATEST OCAT INFO FOR OBSID 50601:                                     
No ocat info found for obsid 50601                                    
                                                                      
                                                                      
2016:297:15:00:21.997   11652019  ACISPKT     AA00000000              
                                                                      
2016:297:15:00:21.997   11652019  ORBPOINT    XEF1000                 
                                                                      
==> The requested SI_MODE for the outbound CTI is TE_007AC            
                                                                      
2016:297:15:00:25.997   11652034  ACISPKT     AA00000000              
                                                                      
2016:297:15:00:29.997   11652050  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:297:15:00:53.997   11652143  ACISPKT     WSPOW0CF3F              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps; std I array                      
                                                                      
2016:297:15:01:56.997   11652389  ACISPKT     WBTX_QUIET              
2016:297:15:02:00.997   11652405  ACISPKT     WT007AC024              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x007ac024                            
   fepCcdSelect               =    3    7    0    1    2    6         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 32                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3750                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:297:15:02:04.997   11652420  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 50601                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_007ACB is WT007AC024 and is stored.
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-OUT,50601,OORMPDS,CSELFMT2,ENAB)
                                                                      
2016:297:15:02:08.997   11652436  ACISPKT     RS_0000001              
2016:297:15:02:12.997   11652452  ACISPKT     RH_0000001              
2016:297:15:02:35.997   11652541  ACISPKT     RBTXINGALL              
2016:297:17:47:00.997   11691039  COMMAND_SW  OORMPEN                 
                                                                      
  ==> Exit leg pad time is 10.00 ks.                                  
                                                                      
AE-8 EVENTS TIME CHECK:                                               
 from backstop: XE1RADZ0 = 297:15:00:21                               
 from CRM file: XE1RADZ0 = 297:15:00:21                               
                                                                      
 ==> CRM Pad Time: 10 ks and Backstop Pad Time: 10.00 ks agree.       
                                                                      
2016:297:17:47:01.997   11691043  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of  8.50 ks.                              
                                                                      
2016:297:17:47:01.997   11691043  SIMTRANS    75624  (ACIS-S)         
                                                                      
  ==> THERE IS A Z-SIM OF  0.00 mm FOR THIS OBSERVATION.              
                                                                      
2016:297:17:47:02.997   11691047  ACISPKT     AA00000000              
                                                                      
2016:297:17:47:06.997   11691062  ACISPKT     AA00000000              
                                                                      
2016:297:17:47:10.997   11691078  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:297:17:47:34.997   11691172  ACISPKT     WSPOW0EC3E              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2 3 4 5;  I2 I3 S1 S2 S3            
                                                                      
2016:297:17:48:37.997   11691418  ACISPKT     WT0046E034              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x0046e034                            
   fepCcdSelect               =   10    7    5    6    3    2         
   fepMode                    = 3 # FEP_TE_MODE_EV5x5                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 0                                     
   subarrayRowCount           = 1023                                  
   primaryExposure            = 31                                    
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:297:17:48:41.997   11691433  ACISPKT     XTZ0000005              
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,50601,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:297:17:48:45.997   11691449  ACISPKT     RS_0000001              
2016:297:17:48:49.997   11691464  ACISPKT     RH_0000001              
2016:297:17:50:01.997   11691745  MP_OBSID    18879                   
                                                                      
  ==> ObsID change occurs 2.9 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 18879:                                     
Target Name: Gaia16apd	SI Mode: TE_0046E                              
Instrument: ACIS-S	Grating: NONE	Type: DDT                            
Exposure Time: 30	Remaining Exposure time: 30                         
Offset: Y: 0	Z: 0	Z-sim:                                              
ACIS Exposure Mode: TE	Event TM Format: VF	Frame Time:                
Chips Turned On: NNYY NYYYNN                                          
Subarray Type: NONE	Start: 	Rows: 	Frame Time:                        
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
---------------------------------------------------------------------------
 Parameter block and set up check for 18879                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_0046EB is WT0046E034 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
2016:297:22:00:01.285 	REAL-TIME COMM BEGINS	2016:297:18:00:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:297:23:30:01.285 	REAL-TIME COMM ENDS	2016:297:19:30:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:298:02:31:19.997   11813806  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 30.00 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
2016:298:02:31:19.997   11813806  SIMTRANS    70808  (ACIS-S)         
                                                                      
  ==> THERE IS A Z-SIM OF -12.11 mm FOR THIS OBSERVATION.             
                                                                      
2016:298:02:34:19.997   11814508  COMMAND_HW  CSELFMT4                
                                                                      
2016:298:02:34:19.997   11814508  MP_OBSID    18084                   
                                                                      
  ==> ObsID change occurs 3.0 minutes after stop science.             
                                                                      
LATEST OCAT INFO FOR OBSID 18084:                                     
Target Name: GX349+2	SI Mode: TE_00C82                                
Instrument: ACIS-S	Grating: HETG	Type: GO                             

Exposure Time: 22	Remaining Exposure time: 22                         
Offset: Y: 0	Z: -0.3	Z-sim: -12.1

ACIS Exposure Mode: TE	Event TM Format: F	Frame Time:                 
Chips Turned On: NNNN NNYYNN                                          
Subarray Type: CUSTOM	Start: 10	Rows: 134	Frame Time:                 
Duty Cycle: N	Number: 	Tprimary: 	Tsecondary:                         
Onchip Summing: N	Rows: 1	Columns: 1                                  
Event Filter: N	Lower: 	Range:                                        
Window Filter: N	Start Row: 	Start Column:                            
Height: 	Width:                                                       
Lower Energy: 	Energy Range: 	Sample Rate:                            
Dither:                                                               
Cycle: 17	Obj_Flag: NO                                                
                                                                      
                                                                      
2016:298:02:34:54.336   11814642  COMMAND_SW  4OHETGIN                
                                                                      
2016:298:02:38:37.797   11815514  COMMAND_HW  CSELFMT2                
                                                                      
2016:298:03:07:07.688   11822187  ACISPKT     AA00000000              
                                                                      
2016:298:03:07:11.688   11822203  ACISPKT     AA00000000              
                                                                      
2016:298:03:07:15.688   11822218  ACISPKT     WSPOW00000              
                                                                      
  ==> WSPOW COMMAND LOADS: All Feps down; All vids down               
                                                                      
2016:298:03:07:39.688   11822312  ACISPKT     WSPOW0C006              
                                                                      
  ==> WSPOW COMMAND LOADS: Feps 1 2;  S2 S3                           
                                                                      
2016:298:03:08:42.688   11822558  ACISPKT     WT00C82014              
                                                                      
ACIS PBLOCK LOADS:                                                    
   parameterBlockId           = 0x00c82014                            
   fepCcdSelect               =   10    7    6   10   10   10         
   fepMode                    = 2 # FEP_TE_MODE_EV3x3                 
   bepPackingMode             = 0 # BEP_TE_MODE_FAINT                 
   recomputeBias              = 1                                     
   trickleBias                = 1                                     
   subarrayStartRow           = 9                                     
   subarrayRowCount           = 133                                   
   primaryExposure            = 5                                     
   secondaryExposure          = 0                                     
   dutyCycle                  = 0                                     
   lowerEventAmplitude        = 20                                    
   eventAmplitudeRange        = 3250                                  
   windowSlotIndex            = 65535                                 
                                                                      
                                                                      
2016:298:03:08:46.688   11822573  ACISPKT     XTZ0000005              
---------------------------------------------------------------------------
 Parameter block and set up check for 18084                           
---------------------------------------------------------------------------
                                                                      
  ==> Parameter Block for SI mode TE_00C82B is WT00C82014 and is stored.
                                                                      
  ==> FP instrument, Grating and SIM-Z offsets OK.                    
                                                                      
  ==> Parameter Block and OCAT are consistent for this observation    
                                                                      
                                                                      
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-IN,LETG-OUT,18084,OORMPEN,CSELFMT2,ENAB)
                                                                      
2016:298:03:08:50.688   11822589  ACISPKT     RS_0000001              
2016:298:03:08:54.688   11822605  ACISPKT     RH_0000001              
                                                                      
2016:298:03:30:01.285 	REAL-TIME COMM BEGINS	2016:297:23:30:01.285  EDT
                                                                      
                                                                      
                                                                      
2016:298:05:00:01.285 	REAL-TIME COMM ENDS	2016:298:01:00:01.285  EDT 
                                                                      
                                                                      
  ==> COMM DURATION:  90.00 mins.                                     
                                                                      
2016:298:09:27:00.688   11911135  ACISPKT     AA00000000              
                                                                      
  ==> ACIS integration time of 22.00 ks.                              
                                                                      
 This is 100.00% of the requested time.                               
                                                                      
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
                                                                      
                                                                      
                                                                      
-- CHANDRA LOAD END --                                                
                                                                      
                                                                      
************************                                              
ACIS LOAD REVIEW SUMMARY                                              
************************                                              
                                                                      
                                                                      
THERE ARE 27 REAL-TIME COMM PASSAGES IN THIS LOAD.                    
                                                                      
FREQUENCY OF ACIS COMMAND OCCURRENCES TABLE:                          
----------------------------------------------------------------------
  OBSIDs  WSVIDALLDNs  RS_0000001  RH_0000001  X[TC]Z0000005  AA00000000 
----------------------------------------------------------------------
    34        4           27          24          24          73      
                                                                      
**NOTE: There are 3 perigee crossings in this load.                   
                                                                      
FREQUENCY OF OTG INSERTIONS/RETRACTIONS:                              
--------------------------------------------                          
  LETG_INs  LETG_REs  HETG_INs  HETG_REs                              
--------------------------------------------                          
     1         1         5         4                                  
                                                                      
--------------------------------------------------------------------------
                                                                      
                                                                      
--------------------------------------------------------------------------
                                                                      
--------------------------------------------------------------------------
                                                                      
AT LEAST ONE INSTANCE OF THE FOLLOWING TYPES OF WARNINGS OR ERRORS WERE ENCOUNTERED:
                                                                      
o. There is a change from FMT2 before an ACIS stop science.           
                                                                      
--------------------------------------------------------------------------
                                                                      
 ACIS LOAD REVIEW FAILED