ACIS LOAD REVIEW OUTPUT:
FOR REVIEW BY CXC ACIS OPS PERSONNEL
-------------------------------------------------
USING /data/acis/LoadReviews/2024/FEB1124/oflsa/CR042_0302.backstop
LOAD HISTORY FROM: /data/acis/LoadReviews/2024/FEB1124/oflsa/ACIS-History_edit.txt
-- CHANDRA LOAD START --
CHANDRA STATUS ARRAY AT START OF LOAD REVIEW (FROM PREVIOUS LOAD HISTORY FILE):
(FP SI,HETG status,LETG status,current OBSID,RadMon status,current TLM FMT,Dither)
= (HRC-S,HETG-IN,LETG-OUT,43713,OORMPDS,CSELFMT2,ENAB)
2024:042:03:52:00.000 3611919 ACISPKT AA00000000
ACISPKT AND/OR POWER COMMAND ERROR:
2024:042:03:52:03.00 ACISPKT Rule #0 - ERROR Less than 4 second delay between consecutive ACISPKT commands
2024:042:03:52:03.000 3611931 ACISPKT AA00000000
2024:042:03:53:06.000 3612177 COMMAND_SW OORMPDS
==>The requested SI_MODE for the inbound CTI is
2024:042:03:54:02.000 3612395 COMMAND_SW OORMPEN
==> Exit leg pad time is 3642.84 ks.
>>>ERROR: RadMon EN occurs well after an E1 exit (>15ks).
-OR- RadMon EN encountered prior to a XE1RADZ0/XEF1000.
2024:042:06:13:08.510 3631845 ORBPOINT EAPOGEE
2024:042:06:33:28.684 3649729 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:042:06:33:43.684 3649787 COMMAND_HW CSELFMT6
2024:042:06:33:43.684 3649787 MP_OBSID 29252
LATEST OCAT INFO FOR OBSID 29252:
Target Name: 2MASS J08194059+0823581 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:042:06:34:18.023 3649921 COMMAND_SW 4OHETGRE
2024:042:06:38:01.484 3650793 COMMAND_HW CSELFMT2
2024:042:06:39:29.084 3651135 SIMFOCUS -536
2024:042:06:57:13.700 3655290 ACISPKT AA00000000
2024:042:06:57:17.700 3655305 ACISPKT AA00000000
2024:042:06:57:21.700 3655321 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:042:06:57:45.700 3655414 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:042:06:58:48.700 3655660 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:042:06:58:52.700 3655676 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29252
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,29252,OORMPEN,CSELFMT2,ENAB)
>>> Warning - Long Dwell: 2024:042:06:58:52.700 Dwell time: 130021.7 seconds
2024:042:06:58:56.700 3655691 ACISPKT RS_0000001
2024:042:06:59:00.700 3655707 ACISPKT RH_0000001
2024:042:10:06:10.700 3699531 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:042:10:06:10.700 3699531 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:042:10:08:10.100 3699997 SIMFOCUS -418
2024:042:10:09:10.700 3700234 COMMAND_HW CSELFMT6
2024:042:10:09:10.700 3700234 MP_OBSID 29258
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29258:
Target Name: MCG -6 -30-15 SI Mode: TE_00B92
Instrument: ACIS-S Grating: HETG Type: GTO
Exposure Time: 12 Remaining Exposure time: 12
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: F Frame Time:
Chips Turned On: NNNN NYYYYN
Subarray Type: CUSTOM Start: 1 Rows: 774 Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:042:10:09:29.500 3700307 SIMFOCUS -468
2024:042:10:09:45.039 3700368 COMMAND_SW 4OHETGIN
2024:042:10:13:28.500 3701240 COMMAND_HW CSELFMT2
2024:042:10:31:52.716 3705549 ACISPKT AA00000000
2024:042:10:31:56.716 3705565 ACISPKT AA00000000
2024:042:10:32:00.716 3705580 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:042:10:32:24.716 3705674 ACISPKT WSPOW1E01E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; S1 S2 S3 S4
2024:042:10:33:27.716 3705920 ACISPKT WT00B92014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00b92014
fepCcdSelect = 10 7 5 6 8 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 773
primaryExposure = 24
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:042:10:33:31.716 3705935 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29258
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00B92B is WT00B92014 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-IN,LETG-OUT,29258,OORMPEN,CSELFMT2,ENAB)
2024:042:10:33:35.716 3705951 ACISPKT RS_0000001
2024:042:10:33:39.716 3705967 ACISPKT RH_0000001
2024:042:11:15:01.285 REAL-TIME COMM BEGINS 2024:042:06:15:01.285 EST
2024:042:12:45:01.285 REAL-TIME COMM ENDS 2024:042:07:45:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:042:14:12:12.716 3757139 ACISPKT AA00000000
==> ACIS integration time of 12.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:042:14:12:12.716 3757139 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:042:14:14:12.116 3757605 SIMFOCUS -536
2024:042:14:15:12.716 3757842 COMMAND_HW CSELFMT6
2024:042:14:15:12.716 3757842 MP_OBSID 29253
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29253:
Target Name: 2MASS J08194059+0823581 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:042:14:15:47.055 3757976 COMMAND_SW 4OHETGRE
2024:042:14:19:30.516 3758848 COMMAND_HW CSELFMT2
2024:042:14:35:57.733 3762700 ACISPKT AA00000000
2024:042:14:36:01.733 3762716 ACISPKT AA00000000
2024:042:14:36:05.733 3762732 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:042:14:36:29.733 3762825 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:042:14:37:32.733 3763071 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:042:14:37:36.733 3763087 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29253
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,29253,OORMPEN,CSELFMT2,ENAB)
2024:042:14:37:40.733 3763102 ACISPKT RS_0000001
2024:042:14:37:44.733 3763118 ACISPKT RH_0000001
2024:042:17:44:54.733 3806942 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:042:17:44:54.733 3806942 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:042:17:46:54.133 3807408 SIMFOCUS -418
2024:042:17:47:54.733 3807645 COMMAND_HW CSELFMT6
2024:042:17:47:54.733 3807645 MP_OBSID 29259
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29259:
Target Name: MCG -6 -30-15 SI Mode: TE_00B92
Instrument: ACIS-S Grating: HETG Type: GTO
Exposure Time: 14 Remaining Exposure time: 14
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: F Frame Time:
Chips Turned On: NNNN NYYYYN
Subarray Type: CUSTOM Start: 1 Rows: 774 Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:042:17:48:13.533 3807718 SIMFOCUS -468
2024:042:17:48:29.072 3807779 COMMAND_SW 4OHETGIN
2024:042:17:52:12.533 3808651 COMMAND_HW CSELFMT2
2024:042:18:10:36.748 3812960 ACISPKT AA00000000
2024:042:18:10:40.748 3812976 ACISPKT AA00000000
2024:042:18:10:44.748 3812991 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:042:18:11:08.748 3813085 ACISPKT WSPOW1E01E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; S1 S2 S3 S4
2024:042:18:12:11.748 3813331 ACISPKT WT00B92014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00b92014
fepCcdSelect = 10 7 5 6 8 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 773
primaryExposure = 24
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:042:18:12:15.748 3813346 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29259
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00B92B is WT00B92014 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-IN,LETG-OUT,29259,OORMPEN,CSELFMT2,ENAB)
2024:042:18:12:19.748 3813362 ACISPKT RS_0000001
2024:042:18:12:23.748 3813378 ACISPKT RH_0000001
2024:042:20:00:01.285 REAL-TIME COMM BEGINS 2024:042:15:00:01.285 EST
2024:042:21:30:01.285 REAL-TIME COMM ENDS 2024:042:16:30:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:042:22:19:16.748 3871184 ACISPKT AA00000000
==> ACIS integration time of 13.70 ks.
This is 97.86% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:042:22:22:16.748 3871887 COMMAND_HW CSELFMT6
2024:042:22:22:16.748 3871887 MP_OBSID 29243
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29243:
Target Name: SDSS J092002.85+054407.7 SI Mode: TE_00D4C
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: F Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: Y Lower: 0.24 Range: 11.9
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:042:22:22:51.087 3872021 COMMAND_SW 4OHETGRE
2024:042:22:26:34.548 3872893 COMMAND_HW CSELFMT2
2024:042:22:40:37.506 3876182 ACISPKT AA00000000
2024:042:22:40:41.506 3876198 ACISPKT AA00000000
2024:042:22:40:45.506 3876214 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:042:22:41:09.506 3876307 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:042:22:42:12.506 3876553 ACISPKT WT00D4C014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00d4c014
fepCcdSelect = 10 7 6 10 10 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 2975
windowSlotIndex = 65535
2024:042:22:42:16.506 3876569 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29243
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00D4CB is WT00D4C014 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29243,OORMPEN,CSELFMT2,ENAB)
2024:042:22:42:20.506 3876584 ACISPKT RS_0000001
2024:042:22:42:24.506 3876600 ACISPKT RH_0000001
2024:043:01:45:33.506 3919484 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:043:01:48:33.506 3920186 MP_OBSID 27378
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 27378:
Target Name: WISEA J050222.16-341201.6 SI Mode: TE_00600
Instrument: ACIS-S Grating: NONE Type: GTO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN YYYYYY
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:043:01:52:39.279 3921145 ACISPKT AA00000000
2024:043:01:52:43.279 3921161 ACISPKT AA00000000
2024:043:01:52:47.279 3921177 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:043:01:53:11.279 3921270 ACISPKT WSPOW3F03F
==> WSPOW COMMAND LOADS: All Feps; std S array
2024:043:01:54:14.279 3921516 ACISPKT WT00600034
ACIS PBLOCK LOADS:
parameterBlockId = 0x00600034
fepCcdSelect = 4 7 5 6 8 9
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 32
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:043:01:54:18.279 3921532 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 27378
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00600B is WT00600034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,27378,OORMPEN,CSELFMT2,ENAB)
2024:043:01:54:22.279 3921547 ACISPKT RS_0000001
2024:043:01:54:26.279 3921563 ACISPKT RH_0000001
2024:043:04:30:01.285 REAL-TIME COMM BEGINS 2024:42:23:30:01.285 EST
2024:043:05:04:19.279 3966023 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:043:05:07:19.279 3966726 MP_OBSID 25561
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 25561:
Target Name: SDSS J140701.59+190417.9 SI Mode: TE_005C6
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 5.2 Remaining Exposure time: 5.2
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYYN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.002222 deg Y Freq: 0.360000 deg/sec Y Phase: 0
Z Amp: 0.002222 deg Z Freq: 0.509100 deg/sec Z Phase: 0
Cycle: 25 Obj_Flag: NO
2024:043:05:33:36.246 3972880 ACISPKT AA00000000
2024:043:05:33:40.246 3972896 ACISPKT AA00000000
2024:043:05:33:44.246 3972911 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:043:05:34:08.246 3973005 ACISPKT WSPOW1C00E
==> WSPOW COMMAND LOADS: Feps 1 2 3; S2 S3 S4
2024:043:05:35:11.246 3973251 ACISPKT WT005C6024
ACIS PBLOCK LOADS:
parameterBlockId = 0x005c6024
fepCcdSelect = 10 7 6 8 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:043:05:35:15.246 3973266 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 25561
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_005C6B is WT005C6024 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,25561,OORMPEN,CSELFMT2,ENAB)
2024:043:05:35:19.246 3973282 ACISPKT RS_0000001
2024:043:05:35:23.246 3973298 ACISPKT RH_0000001
2024:043:05:47:59.246 3976248 AOENDITH AOENDITH
==> DITHER ENABLED
2024:043:06:00:01.285 REAL-TIME COMM ENDS 2024:043:01:00:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:043:07:22:55.444 3998477 ACISPKT AA00000000
==> ACIS integration time of 5.31 ks.
This is 102.04% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:043:07:22:55.444 3998477 SIMTRANS -99616 (HRC-S)
2024:043:07:25:55.444 3999179 COMMAND_HW CSELFMT6
2024:043:07:25:55.444 3999179 MP_OBSID 43712
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 43712:
No ocat info found for obsid 43712
2024:043:07:26:29.783 3999313 COMMAND_SW 4OHETGIN
2024:043:07:28:32.844 3999794 COMMAND_SW OORMPDS
==>The requested SI_MODE for the inbound CTI is
2024:043:07:30:13.244 4000185 COMMAND_HW CSELFMT2
2024:043:07:44:21.310 4003495 AOENDITH AOENDITH
==> DITHER ENABLED
2024:043:08:40:51.310 4016724 MP_OBSID 43711
LATEST OCAT INFO FOR OBSID 43711:
No ocat info found for obsid 43711
2024:043:09:35:40.089 4029558 ACISPKT AA00000000
2024:043:09:35:40.089 4029558 ORBPOINT EEF1000
==> Entry leg pad time is 7.63 ks.
AE-8 EVENTS TIME CHECK:
from backstop: EE1RADZ0 = 043:09:35:40
from CRM file: EE1RADZ0 = 043:09:35:40
>>>CRM Pad Time: 0 ks and Backstop Pad Time: 7.63 ks do not agree!!
This could be due to extended CTI measurement
-OR- error in the load.
2024:043:09:35:49.089 4029593 ACISPKT WSPOW0002A
==> WSPOW COMMAND LOADS: Feps 1 3 5; All vids down
2024:043:09:36:52.089 4029839 ACISPKT RS_0000001
2024:043:12:45:52.906 4074096 MP_OBSID 43710
LATEST OCAT INFO FOR OBSID 43710:
No ocat info found for obsid 43710
2024:043:13:30:41.000 4084586 MP_OBSID 43709
LATEST OCAT INFO FOR OBSID 43709:
No ocat info found for obsid 43709
2024:043:13:56:39.880 4089620 ORBPOINT EPERIGEE
>>>ERROR: The radzone ACIS commanding triplet was not seen
>>>ERROR: Time delta between the last WSVIDALLDN and the 2nd last AA00000000 is greater than 10.0 mins!
2024:043:14:20:31.000 4096255 MP_OBSID 43708
LATEST OCAT INFO FOR OBSID 43708:
No ocat info found for obsid 43708
2024:043:14:52:51.000 4103825 MP_OBSID 43707
LATEST OCAT INFO FOR OBSID 43707:
No ocat info found for obsid 43707
2024:043:16:13:21.633 4122677 MP_OBSID 43706
LATEST OCAT INFO FOR OBSID 43706:
No ocat info found for obsid 43706
2024:043:16:51:40.089 4131646 ACISPKT RBTXINGBLL
2024:043:17:01:40.089 4131646 ORBPOINT XEF1000
==> The requested SI_MODE for the outbound CTI is TE_007AE
>>>ERROR: Time delta between XE1RADZ0/XEF1000 and EPERIGEE is less than 3.25 hrs.
2024:043:17:44:51.579 4144101 MP_OBSID 43705
LATEST OCAT INFO FOR OBSID 43705:
No ocat info found for obsid 43705
2024:043:17:45:01.285 REAL-TIME COMM BEGINS 2024:043:12:45:01.285 EST
2024:043:18:31:47.529 4155090 MP_OBSID 43704
LATEST OCAT INFO FOR OBSID 43704:
No ocat info found for obsid 43704
2024:043:19:15:01.285 REAL-TIME COMM ENDS 2024:043:14:15:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:043:19:48:19.089 4173008 COMMAND_SW OORMPEN
==> Exit leg pad time is 10.00 ks.
AE-8 EVENTS TIME CHECK:
from backstop: XE1RADZ0 = 043:17:01:40
from CRM file: XE1RADZ0 = 043:17:01:40
>>>CRM Pad Time: 0 ks and Backstop Pad Time: 10.00 ks do not agree!!
This could be due to extended CTI measurement
-OR- error in the load.
>>>ERROR: RADMON occurs 612.65 min AFTER stop science.
2024:043:19:48:20.089 4173012 COMMAND_HW CSELFMT6
2024:043:19:48:20.089 4173012 SIMTRANS 89824 (ACIS-I)
==> THERE IS A Z-SIM OF -7.75 mm FOR THIS OBSERVATION.
2024:043:19:48:21.089 4173016 MP_OBSID 26929
LATEST OCAT INFO FOR OBSID 26929:
Target Name: 1RXS J054255.8-212551 SI Mode: TE_00D58
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 47 Remaining Exposure time: 47
Offset: Y: -3 Z: 0 Z-sim: -7.752
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:043:19:48:54.428 4173146 COMMAND_SW 4OHETGRE
2024:043:19:52:37.889 4174018 COMMAND_HW CSELFMT2
2024:043:19:53:10.689 4174146 ACISPKT AA00000000
2024:043:19:53:14.689 4174162 ACISPKT AA00000000
2024:043:19:53:18.689 4174177 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:043:19:53:42.689 4174271 ACISPKT WSPOW00E0E
==> WSPOW COMMAND LOADS: Feps 1 2 3; I1 I2 I3
2024:043:19:54:16.489 4174403 SIMFOCUS -536
2024:043:19:54:45.689 4174517 ACISPKT WT00D58014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00d58014
fepCcdSelect = 10 3 2 1 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:043:19:54:49.689 4174532 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 26929
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00D58B is WT00D58014 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,26929,OORMPEN,CSELFMT2,ENAB)
>>> Warning - Long Dwell: 2024:043:19:54:49.689 Dwell time: 45114.2 seconds
2024:043:19:54:53.689 4174548 ACISPKT RS_0000001
2024:043:19:54:57.689 4174564 ACISPKT RH_0000001
2024:044:03:20:01.285 REAL-TIME COMM BEGINS 2024:43:22:20:01.285 EST
2024:044:04:50:01.285 REAL-TIME COMM ENDS 2024:43:23:50:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:044:09:59:03.689 4372207 ACISPKT AA00000000
==> ACIS integration time of 49.50 ks.
This is 105.32% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:044:09:59:03.689 4372207 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:044:10:00:59.089 4372657 SIMFOCUS -418
2024:044:10:02:03.689 4372909 MP_OBSID 27202
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 27202:
Target Name: IC 2431 SI Mode: TE_0057A
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 11 Remaining Exposure time: 11
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:044:10:02:18.489 4372967 SIMFOCUS -468
2024:044:10:12:24.291 4375331 ACISPKT AA00000000
2024:044:10:12:28.291 4375346 ACISPKT AA00000000
2024:044:10:12:32.291 4375362 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:044:10:12:56.291 4375456 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:044:10:13:59.291 4375702 ACISPKT WT0057A034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0057a034
fepCcdSelect = 10 7 6 10 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:044:10:14:03.291 4375717 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 27202
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0057AB is WT0057A034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,27202,OORMPEN,CSELFMT2,ENAB)
2024:044:10:14:07.291 4375733 ACISPKT RS_0000001
2024:044:10:14:11.291 4375748 ACISPKT RH_0000001
2024:044:13:50:15.291 4426340 ACISPKT AA00000000
==> ACIS integration time of 12.00 ks.
This is 109.09% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:044:13:53:15.291 4427042 MP_OBSID 29275
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29275:
Target Name: WISEA J050222.16-341201.6 SI Mode: TE_00600
Instrument: ACIS-S Grating: NONE Type: GTO
Exposure Time: 15 Remaining Exposure time: 15
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN YYYYYY
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:044:13:59:20.817 4428468 ACISPKT AA00000000
2024:044:13:59:24.817 4428484 ACISPKT AA00000000
2024:044:13:59:28.817 4428500 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:044:13:59:52.817 4428593 ACISPKT WSPOW3F03F
==> WSPOW COMMAND LOADS: All Feps; std S array
2024:044:14:00:55.817 4428839 ACISPKT WT00600034
ACIS PBLOCK LOADS:
parameterBlockId = 0x00600034
fepCcdSelect = 4 7 5 6 8 9
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 32
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:044:14:00:59.817 4428855 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29275
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00600B is WT00600034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29275,OORMPEN,CSELFMT2,ENAB)
2024:044:14:01:03.817 4428870 ACISPKT RS_0000001
2024:044:14:01:07.817 4428886 ACISPKT RH_0000001
2024:044:14:25:01.285 REAL-TIME COMM BEGINS 2024:044:09:25:01.285 EST
2024:044:15:45:01.285 REAL-TIME COMM ENDS 2024:044:10:45:01.285 EST
==> COMM DURATION: 80.00 mins.
2024:044:18:34:20.817 4492859 ACISPKT AA00000000
==> ACIS integration time of 15.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:044:18:37:20.817 4493561 MP_OBSID 29273
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29273:
Target Name: IC 2431 SI Mode: TE_0057A
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:044:18:50:37.553 4496670 ACISPKT AA00000000
2024:044:18:50:41.553 4496686 ACISPKT AA00000000
2024:044:18:50:45.553 4496702 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:044:18:51:09.553 4496795 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:044:18:52:12.553 4497041 ACISPKT WT0057A034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0057a034
fepCcdSelect = 10 7 6 10 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:044:18:52:16.553 4497057 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29273
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0057AB is WT0057A034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29273,OORMPEN,CSELFMT2,ENAB)
2024:044:18:52:20.553 4497072 ACISPKT RS_0000001
2024:044:18:52:24.553 4497088 ACISPKT RH_0000001
2024:044:21:40:24.263 4536423 ORBPOINT EAPOGEE
2024:044:22:11:48.553 4543777 ACISPKT AA00000000
==> ACIS integration time of 11.00 ks.
This is 110.00% of the requested time.
==>ERROR: Scheduled time is greater than 110%.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:044:22:14:48.553 4544479 MP_OBSID 26710
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 26710:
Target Name: DES J0322-18 SI Mode: TE_0057A
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 11 Remaining Exposure time: 11
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:044:22:45:38.675 4551699 ACISPKT WSVIDALLDN
2024:044:22:45:56.675 4551769 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:044:22:46:59.675 4552015 ACISPKT WT0057B034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0057b034
fepCcdSelect = 10 7 6 10 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 0
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:044:22:47:03.675 4552031 ACISPKT RS_0000001
2024:044:22:47:07.675 4552046 ACISPKT RH_0000001
2024:044:22:47:30.675 4552136 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 26710
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0057A is WT0057B034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,26710,OORMPEN,CSELFMT2,ENAB)
2024:045:02:07:37.675 4598993 ACISPKT AA00000000
==> ACIS integration time of 12.01 ks.
This is 109.15% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:045:02:07:37.675 4598993 SIMTRANS -50504 (HRC-I)
2024:045:02:10:37.675 4599695 COMMAND_HW CSELFMT1
2024:045:02:10:37.675 4599695 MP_OBSID 26963
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 26963:
No ACIS info found for obsid 26963.
This is an HRC-I observation.
2024:045:02:12:07.075 4600044 SIMFOCUS -716
2024:045:02:23:38.032 4602741 ACISPKT AA00000000
2024:045:02:23:42.032 4602756 ACISPKT AA00000000
2024:045:02:23:46.032 4602772 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:045:02:24:10.032 4602865 ACISPKT WSPOW08812
==> WSPOW COMMAND LOADS: Feps 1 4; I3 S3
2024:045:02:25:13.032 4603111 ACISPKT RS_0000001
2024:045:02:25:17.032 4603127 ACISPKT RH_0000001
2024:045:02:25:40.032 4603217 ACISPKT WT00DAA014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00daa014
fepCcdSelect = 10 7 10 10 3 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 0
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 33
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3750
windowSlotIndex = 4
2024:045:02:25:44.032 4603232 ACISPKT W200138014
ACIS 2D WINDOW BLOCK LOADS:
windowSlotIndex = 4
windowBlockId = 0x00138014
ccdId = 0
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
ccdId = 1
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
ccdId = 2
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
ccdId = 3
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
ccdId = 4
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
ccdId = 5
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
ccdId = 6
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
ccdId = 7
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
ccdId = 8
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
ccdId = 9
ccdRow = 0
ccdColumn = 0
width = 1023
height = 1023
sampleCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
2024:045:02:25:48.032 4603248 ACISPKT XTZ0000005
====> CHANDRA STATUS ARRAY=(HRC-I,HETG-OUT,LETG-OUT,26963,OORMPEN,CSELFMT1,ENAB)
2024:045:02:56:33.032 4610448 AOENDITH AOENDITH
==> DITHER ENABLED
2024:045:02:58:09.032 SCS-134 Activation: HRC Observation Begun
Time between SI Mode load start and SCS-134 activation is good:
Required Delta T: 2071.0 Actual Delta T: 2071.0
2024:045:04:15:01.285 REAL-TIME COMM BEGINS 2024:44:23:15:01.285 EST
2024:045:04:26:23.032 4631482 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
>>>ERROR: SIM TRANSLATION OCCURS 120.58 minutes AFTER A START SCIENCE.
2024:045:04:26:35.032 215PCAOF command: HRC Observation Ends
2024:045:04:26:35.032 4631529 ACISPKT AA00000000
==> ACIS integration time of 0.01 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:045:04:26:37.032 4631537 COMMAND_HW CSELFMT2
2024:045:04:26:37.032 4631537 MP_OBSID 27141
==> ObsID change occurs 0.0 minutes after stop science.
>>>ERROR: ObsID change occurs less than 3 minutes after a stop science command.
LATEST OCAT INFO FOR OBSID 27141:
Target Name: [APH2018] SDSS J1020+1040 nebula SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 9.1 Remaining Exposure time: 9.1
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:045:04:31:16.432 4632627 SIMFOCUS -486
2024:045:04:32:37.832 4632945 SIMFOCUS -536
2024:045:04:35:41.452 4633661 ACISPKT AA00000000
2024:045:04:35:45.452 4633677 ACISPKT AA00000000
2024:045:04:35:49.452 4633692 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:045:04:36:13.452 4633786 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:045:04:37:16.452 4634032 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:045:04:37:20.452 4634048 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 27141
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,27141,OORMPEN,CSELFMT2,ENAB)
2024:045:04:37:24.452 4634063 ACISPKT RS_0000001
2024:045:04:37:28.452 4634079 ACISPKT RH_0000001
2024:045:04:51:28.452 4637357 AOENDITH AOENDITH
==> DITHER ENABLED
2024:045:05:45:01.285 REAL-TIME COMM ENDS 2024:045:00:45:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:045:07:44:38.452 4677903 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 109.89% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:045:07:47:38.452 4678606 MP_OBSID 26682
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 26682:
Target Name: XMMU J183239.7-091610 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:045:08:25:48.344 4687542 ACISPKT WSVIDALLDN
2024:045:08:26:06.344 4687612 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:045:08:27:09.344 4687858 ACISPKT WT006E7034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e7034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 0
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:045:08:27:13.344 4687873 ACISPKT RS_0000001
2024:045:08:27:17.344 4687889 ACISPKT RH_0000001
2024:045:08:27:40.344 4687979 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 26682
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6 is WT006E7034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,26682,OORMPEN,CSELFMT2,ENAB)
2024:045:11:14:27.344 4727031 ACISPKT AA00000000
==> ACIS integration time of 10.01 ks.
This is 100.07% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:045:11:17:27.344 4727733 MP_OBSID 29270
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29270:
Target Name: [APH2018] SDSS J1020+1040 nebula SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 9.1 Remaining Exposure time: 9.1
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:045:11:55:37.158 4736669 ACISPKT WSVIDALLDN
2024:045:11:55:55.158 4736739 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:045:11:56:58.158 4736985 ACISPKT WT006E7034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e7034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 0
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:045:11:57:02.158 4737001 ACISPKT RS_0000001
2024:045:11:57:06.158 4737016 ACISPKT RH_0000001
2024:045:11:57:29.158 4737106 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29270
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6 is WT006E7034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,29270,OORMPEN,CSELFMT2,ENAB)
2024:045:12:15:01.285 REAL-TIME COMM BEGINS 2024:045:07:15:01.285 EST
2024:045:13:45:01.285 REAL-TIME COMM ENDS 2024:045:08:45:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:045:14:44:16.158 4776158 ACISPKT AA00000000
==> ACIS integration time of 10.01 ks.
This is 109.97% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:045:14:47:16.158 4776860 MP_OBSID 29265
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29265:
Target Name: XMMU J183239.7-091610 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:045:15:25:26.086 4785796 ACISPKT WSVIDALLDN
2024:045:15:25:44.086 4785867 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:045:15:26:47.086 4786112 ACISPKT WT006E7034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e7034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 0
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:045:15:26:51.086 4786128 ACISPKT RS_0000001
2024:045:15:26:55.086 4786144 ACISPKT RH_0000001
2024:045:15:27:18.086 4786233 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29265
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6 is WT006E7034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,29265,OORMPEN,CSELFMT2,ENAB)
2024:045:18:14:05.086 4825285 ACISPKT AA00000000
==> ACIS integration time of 10.01 ks.
This is 100.07% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:045:18:17:05.086 4825988 MP_OBSID 43703
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 43703:
No ocat info found for obsid 43703
2024:045:18:36:14.502 4830473 MP_OBSID 26854
LATEST OCAT INFO FOR OBSID 26854:
Target Name: AGC 721931 SI Mode: TE_00972
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 12.9 Remaining Exposure time: 12.9
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: F Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:045:18:36:14.502 4830473 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:045:18:38:13.902 4830939 SIMFOCUS -418
2024:045:18:39:33.302 4831249 SIMFOCUS -468
2024:045:18:53:26.770 4834501 ACISPKT AA00000000
2024:045:18:53:30.770 4834517 ACISPKT AA00000000
2024:045:18:53:34.770 4834533 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:045:18:53:58.770 4834626 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:045:18:55:01.770 4834872 ACISPKT WT00972024
ACIS PBLOCK LOADS:
parameterBlockId = 0x00972024
fepCcdSelect = 10 7 6 10 10 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:045:18:55:05.770 4834888 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 26854
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00972B is WT00972024 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,26854,OORMPEN,CSELFMT2,ENAB)
2024:045:18:55:09.770 4834903 ACISPKT RS_0000001
2024:045:18:55:13.770 4834919 ACISPKT RH_0000001
2024:045:23:07:02.661 4893881 ACISPKT AA00000000
==> ACIS integration time of 14.14 ks.
This is 109.65% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:045:23:07:02.661 4893881 SIMTRANS -99616 (HRC-S)
2024:045:23:10:02.661 4894583 COMMAND_HW CSELFMT6
2024:045:23:10:02.661 4894583 MP_OBSID 43702
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 43702:
No ocat info found for obsid 43702
2024:045:23:10:37.000 4894717 COMMAND_SW 4OHETGIN
2024:045:23:12:40.061 4895197 COMMAND_SW OORMPDS
==>The requested SI_MODE for the inbound CTI is TE_00B26
2024:045:23:12:40.061 4895197 ACISPKT AA00000000
2024:045:23:12:44.061 4895213 ACISPKT AA00000000
2024:045:23:12:48.061 4895228 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:045:23:13:12.061 4895322 ACISPKT WSPOW0AF3F
==> WSPOW COMMAND LOADS: All Feps; I0 I1 I2 I3 S1 S3
2024:045:23:14:15.061 4895568 ACISPKT WT00B26014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00b26014
fepCcdSelect = 3 7 0 1 2 5
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 32
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3750
windowSlotIndex = 65535
2024:045:23:14:19.061 4895584 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 43702
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00B26B is WT00B26014 and is stored.
>>>ERROR: WE ARE DOING A CTI MEASUREMENT BUT WE ARE NOT IN FMT 2!
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-IN,LETG-OUT,43702,OORMPDS,CSELFMT6,ENAB)
2024:045:23:14:20.461 4895589 COMMAND_HW CSELFMT2
2024:045:23:14:23.061 4895599 ACISPKT RS_0000001
2024:045:23:14:27.061 4895615 ACISPKT RH_0000001
2024:046:00:00:01.285 REAL-TIME COMM BEGINS 2024:046:19:00:01.285 EST
2024:046:00:13:14.852 4909382 MP_OBSID 43701
==> ObsID change occurs 60.5 minutes after stop science.
LATEST OCAT INFO FOR OBSID 43701:
No ocat info found for obsid 43701
2024:046:00:54:47.305 4919108 ACISPKT AA00000000
==> ACIS integration time of 4.63 ks.
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
2024:046:00:57:47.305 4919811 ACISPKT AA00000000
2024:046:00:57:47.305 4919811 ORBPOINT EEF1000
==> Entry leg pad time is 6.31 ks.
AE-8 EVENTS TIME CHECK:
from backstop: EE1RADZ0 = 046:00:57:47
from CRM file: EE1RADZ0 = 046:00:57:47
==> CRM Pad Time: 6.307 ks and Backstop Pad Time: 6.31 ks agree.
2024:046:00:57:56.305 4919846 ACISPKT WSPOW0002A
==> WSPOW COMMAND LOADS: Feps 1 3 5; All vids down
2024:046:00:58:59.305 4920092 ACISPKT RS_0000001
2024:046:01:15:01.285 REAL-TIME COMM ENDS 2024:45:20:15:01.285 EST
==> COMM DURATION: 75.00 mins.
2024:046:02:56:22.012 4947576 MP_OBSID 43700
LATEST OCAT INFO FOR OBSID 43700:
No ocat info found for obsid 43700
2024:046:04:57:30.000 4975938 MP_OBSID 43699
LATEST OCAT INFO FOR OBSID 43699:
No ocat info found for obsid 43699
2024:046:05:24:01.005 4981122 ORBPOINT EPERIGEE
2024:046:05:47:20.000 4987607 MP_OBSID 43698
LATEST OCAT INFO FOR OBSID 43698:
No ocat info found for obsid 43698
2024:046:06:22:40.000 4995880 MP_OBSID 43697
LATEST OCAT INFO FOR OBSID 43697:
No ocat info found for obsid 43697
2024:046:07:51:47.305 5016747 ACISPKT RBTXINGBLL
2024:046:08:01:47.305 5016747 ORBPOINT XEF1000
==> The requested SI_MODE for the outbound CTI is TE_007AC
>>>ERROR: Time delta between XE1RADZ0/XEF1000 and EPERIGEE is less than 3.25 hrs.
2024:046:10:41:40.955 5056528 COMMAND_HW CSELFMT6
2024:046:10:42:15.294 5056662 COMMAND_SW 4OHETGRE
2024:046:10:45:58.755 5057534 COMMAND_HW CSELFMT2
2024:046:10:48:26.305 5058109 COMMAND_SW OORMPEN
==> Exit leg pad time is 10.00 ks.
AE-8 EVENTS TIME CHECK:
from backstop: XE1RADZ0 = 046:08:01:47
from CRM file: XE1RADZ0 = 046:08:01:47
>>>CRM Pad Time: 0 ks and Backstop Pad Time: 10.00 ks do not agree!!
This could be due to extended CTI measurement
-OR- error in the load.
>>>ERROR: RADMON occurs 590.65 min AFTER stop science.
2024:046:10:48:27.305 5058113 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:046:10:48:27.305 5058113 ACISPKT AA00000000
2024:046:10:48:28.305 5058117 MP_OBSID 27146
==> ObsID change occurs 0.0 minutes after stop science.
>>>ERROR: ObsID change occurs less than 3 minutes after a stop science command.
LATEST OCAT INFO FOR OBSID 27146:
Target Name: 2MASS J08194059+0823581 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 16 Remaining Exposure time: 16
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:046:10:48:31.305 5058129 ACISPKT AA00000000
2024:046:10:48:35.305 5058145 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:046:10:48:59.305 5058238 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:046:10:50:02.305 5058484 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:046:10:50:06.305 5058500 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 27146
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,27146,OORMPEN,CSELFMT2,ENAB)
>>> Warning - Long Dwell: 2024:046:10:50:06.305 Dwell time: 35719.0 seconds
2024:046:10:50:10.305 5058515 ACISPKT RS_0000001
2024:046:10:50:14.305 5058531 ACISPKT RH_0000001
2024:046:10:54:27.705 5059520 SIMFOCUS -536
2024:046:11:45:01.285 REAL-TIME COMM BEGINS 2024:046:06:45:01.285 EST
2024:046:13:15:01.285 REAL-TIME COMM ENDS 2024:046:08:15:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:046:15:54:04.305 5129672 ACISPKT AA00000000
==> ACIS integration time of 17.00 ks.
This is 106.25% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:046:15:54:04.305 5129672 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:046:15:56:03.705 5130138 SIMFOCUS -418
2024:046:15:57:04.305 5130375 MP_OBSID 29267
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29267:
Target Name: DES J0322-18 SI Mode: TE_0057A
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 9.5 Remaining Exposure time: 9.5
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:046:15:57:23.105 5130448 SIMFOCUS -468
2024:046:16:09:06.482 5133193 ACISPKT AA00000000
2024:046:16:09:10.482 5133209 ACISPKT AA00000000
2024:046:16:09:14.482 5133224 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:046:16:09:38.482 5133318 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:046:16:10:41.482 5133564 ACISPKT WT0057A034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0057a034
fepCcdSelect = 10 7 6 10 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:046:16:10:45.482 5133579 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29267
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0057AB is WT0057A034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29267,OORMPEN,CSELFMT2,ENAB)
2024:046:16:10:49.482 5133595 ACISPKT RS_0000001
2024:046:16:10:53.482 5133611 ACISPKT RH_0000001
2024:046:19:13:37.482 5176397 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 105.26% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:046:19:13:37.482 5176397 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:046:19:15:36.882 5176863 SIMFOCUS -536
2024:046:19:16:37.482 5177099 MP_OBSID 29272
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29272:
Target Name: 2MASS J08194059+0823581 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 14 Remaining Exposure time: 14
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:046:19:24:13.944 5178881 ACISPKT AA00000000
2024:046:19:24:17.944 5178896 ACISPKT AA00000000
2024:046:19:24:21.944 5178912 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:046:19:24:45.944 5179006 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:046:19:25:48.944 5179251 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:046:19:25:52.944 5179267 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29272
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,29272,OORMPEN,CSELFMT2,ENAB)
2024:046:19:25:56.944 5179283 ACISPKT RS_0000001
2024:046:19:26:00.944 5179298 ACISPKT RH_0000001
2024:046:23:56:30.944 5242635 ACISPKT AA00000000
==> ACIS integration time of 15.00 ks.
This is 107.14% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:046:23:56:30.944 5242635 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:046:23:58:30.344 5243101 SIMFOCUS -418
2024:046:23:59:30.944 5243337 MP_OBSID 29268
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29268:
Target Name: DES J0322-18 SI Mode: TE_0057A
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 9.5 Remaining Exposure time: 9.5
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:046:23:59:49.744 5243411 SIMFOCUS -468
2024:047:00:11:33.512 5246157 ACISPKT AA00000000
2024:047:00:11:37.512 5246173 ACISPKT AA00000000
2024:047:00:11:41.512 5246188 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:047:00:12:05.512 5246282 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:047:00:13:08.512 5246528 ACISPKT WT0057A034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0057a034
fepCcdSelect = 10 7 6 10 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:047:00:13:12.512 5246543 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29268
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0057AB is WT0057A034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29268,OORMPEN,CSELFMT2,ENAB)
2024:047:00:13:16.512 5246559 ACISPKT RS_0000001
2024:047:00:13:20.512 5246575 ACISPKT RH_0000001
2024:047:03:05:01.285 REAL-TIME COMM BEGINS 2024:46:22:05:01.285 EST
2024:047:03:16:04.512 5289361 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 105.26% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:047:03:19:04.512 5290063 MP_OBSID 29183
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29183:
Target Name: 3C 196.1 SI Mode: TE_006CC
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 7.5 Remaining Exposure time: 7.5
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNYY NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:047:03:25:36.871 5291594 ACISPKT AA00000000
2024:047:03:25:40.871 5291610 ACISPKT AA00000000
2024:047:03:25:44.871 5291626 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:047:03:26:08.871 5291719 ACISPKT WSPOW0CC1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I2 I3 S2 S3
2024:047:03:27:11.871 5291965 ACISPKT WT006CC034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006cc034
fepCcdSelect = 10 7 6 3 2 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:047:03:27:15.871 5291981 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29183
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006CCB is WT006CC034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29183,OORMPEN,CSELFMT2,ENAB)
2024:047:03:27:19.871 5291996 ACISPKT RS_0000001
2024:047:03:27:23.871 5292012 ACISPKT RH_0000001
2024:047:04:35:01.285 REAL-TIME COMM ENDS 2024:46:23:35:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:047:05:52:53.871 5326080 ACISPKT AA00000000
==> ACIS integration time of 7.50 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:047:05:55:53.871 5326783 MP_OBSID 28195
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 28195:
Target Name: 2MFGC 3185 SI Mode: TE_00A20
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: F Frame Time:
Chips Turned On: NNNY NNYYYN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 25 Obj_Flag: NO
2024:047:06:01:29.268 5328092 ACISPKT AA00000000
2024:047:06:01:33.268 5328107 ACISPKT AA00000000
2024:047:06:01:37.268 5328123 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:047:06:02:01.268 5328217 ACISPKT WSPOW1C81E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I3 S2 S3 S4
2024:047:06:03:04.268 5328462 ACISPKT WT00A20024
ACIS PBLOCK LOADS:
parameterBlockId = 0x00a20024
fepCcdSelect = 10 7 6 3 8 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:047:06:03:08.268 5328478 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 28195
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00A20B is WT00A20024 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,28195,OORMPEN,CSELFMT2,ENAB)
2024:047:06:03:12.268 5328494 ACISPKT RS_0000001
2024:047:06:03:16.268 5328509 ACISPKT RH_0000001
2024:047:09:18:46.268 5374285 ACISPKT AA00000000
==> ACIS integration time of 10.50 ks.
This is 105.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:047:09:21:46.268 5374987 MP_OBSID 29274
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29274:
Target Name: IC 2431 SI Mode: TE_0057A
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 9 Remaining Exposure time: 9
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:047:09:34:06.202 5377875 ACISPKT AA00000000
2024:047:09:34:10.202 5377890 ACISPKT AA00000000
2024:047:09:34:14.202 5377906 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:047:09:34:38.202 5378000 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:047:09:35:41.202 5378246 ACISPKT WT0057A034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0057a034
fepCcdSelect = 10 7 6 10 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:047:09:35:45.202 5378261 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29274
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0057AB is WT0057A034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29274,OORMPEN,CSELFMT2,ENAB)
2024:047:09:35:49.202 5378277 ACISPKT RS_0000001
2024:047:09:35:53.202 5378292 ACISPKT RH_0000001
2024:047:11:15:01.285 REAL-TIME COMM BEGINS 2024:047:06:15:01.285 EST
2024:047:12:34:27.202 5420103 ACISPKT AA00000000
==> ACIS integration time of 9.75 ks.
This is 108.33% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:047:12:34:27.202 5420103 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:047:12:36:26.602 5420569 SIMFOCUS -536
2024:047:12:37:27.202 5420806 MP_OBSID 28588
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 28588:
Target Name: Abell 370 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 25 Obj_Flag: NO
2024:047:12:45:01.285 REAL-TIME COMM ENDS 2024:047:07:45:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:047:12:49:06.499 5423535 ACISPKT AA00000000
2024:047:12:49:10.499 5423550 ACISPKT AA00000000
2024:047:12:49:14.499 5423566 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:047:12:49:38.499 5423659 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:047:12:50:41.499 5423905 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:047:12:50:45.499 5423921 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 28588
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,28588,OORMPEN,CSELFMT2,ENAB)
2024:047:12:50:49.499 5423936 ACISPKT RS_0000001
2024:047:12:50:53.499 5423952 ACISPKT RH_0000001
2024:047:13:08:14.914 5427754 ORBPOINT EAPOGEE
2024:047:15:58:03.499 5467776 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:047:15:58:03.499 5467776 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:047:16:00:02.899 5468242 SIMFOCUS -418
2024:047:16:01:03.499 5468479 MP_OBSID 28271
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 28271:
Target Name: SDSS J091315.72+015202.0 SI Mode: TE_0057A
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 14.7 Remaining Exposure time: 14.7
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 25 Obj_Flag: NO
2024:047:16:01:22.299 5468552 SIMFOCUS -468
2024:047:16:18:28.718 5472558 ACISPKT AA00000000
2024:047:16:18:32.718 5472573 ACISPKT AA00000000
2024:047:16:18:36.718 5472589 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:047:16:19:00.718 5472683 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:047:16:20:03.718 5472929 ACISPKT WT0057A034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0057a034
fepCcdSelect = 10 7 6 10 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:047:16:20:07.718 5472944 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 28271
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0057AB is WT0057A034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,28271,OORMPEN,CSELFMT2,ENAB)
2024:047:16:20:11.718 5472960 ACISPKT RS_0000001
2024:047:16:20:15.718 5472975 ACISPKT RH_0000001
2024:047:20:22:59.718 5529810 ACISPKT AA00000000
==> ACIS integration time of 13.60 ks.
This is 92.52% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:047:20:25:59.718 5530513 MP_OBSID 43696
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 43696:
No ocat info found for obsid 43696
2024:047:20:50:28.083 5536243 MP_OBSID 28061
LATEST OCAT INFO FOR OBSID 28061:
Target Name: eRASSU J133355.8-665647 SI Mode: TE_0065A
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 15 Remaining Exposure time: 15
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNY NNYYYN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 25 Obj_Flag: NO
2024:047:20:50:28.083 5536243 ACISPKT AA00000000
2024:047:20:50:32.083 5536259 ACISPKT AA00000000
2024:047:20:50:36.083 5536274 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:047:20:51:00.083 5536368 ACISPKT WSPOW1C81E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I3 S2 S3 S4
2024:047:20:52:03.083 5536614 ACISPKT WT0065A034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0065a034
fepCcdSelect = 10 7 6 3 8 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:047:20:52:07.083 5536629 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 28061
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0065AB is WT0065A034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,28061,OORMPEN,CSELFMT2,ENAB)
2024:047:20:52:11.083 5536645 ACISPKT RS_0000001
2024:047:20:52:15.083 5536661 ACISPKT RH_0000001
2024:047:21:55:01.285 REAL-TIME COMM BEGINS 2024:047:16:55:01.285 EST
2024:047:23:25:01.285 REAL-TIME COMM ENDS 2024:047:18:25:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:048:01:47:45.083 5605851 ACISPKT AA00000000
==> ACIS integration time of 16.50 ks.
This is 110.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:048:01:47:45.083 5605851 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:048:01:49:44.483 5606317 SIMFOCUS -536
2024:048:01:50:45.083 5606553 MP_OBSID 29271
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29271:
Target Name: [APH2018] SDSS J1020+1040 nebula SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 9 Remaining Exposure time: 9
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:048:02:02:30.851 5609308 ACISPKT AA00000000
2024:048:02:02:34.851 5609323 ACISPKT AA00000000
2024:048:02:02:38.851 5609339 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:048:02:03:02.851 5609432 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:048:02:04:05.851 5609678 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:048:02:04:09.851 5609694 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29271
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,29271,OORMPEN,CSELFMT2,ENAB)
2024:048:02:04:13.851 5609710 ACISPKT RS_0000001
2024:048:02:04:17.851 5609725 ACISPKT RH_0000001
2024:048:03:10:01.285 REAL-TIME COMM BEGINS 2024:47:22:10:01.285 EST
2024:048:04:40:01.285 REAL-TIME COMM ENDS 2024:47:23:40:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:048:05:06:27.851 5652379 ACISPKT AA00000000
==> ACIS integration time of 9.70 ks.
This is 107.78% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:048:05:09:27.851 5653081 MP_OBSID 26567
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 26567:
Target Name: Swift J1728.9-3613 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 10.5 Remaining Exposure time: 10.5
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:048:05:44:35.467 5661306 ACISPKT WSVIDALLDN
2024:048:05:44:53.467 5661376 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:048:05:45:56.467 5661622 ACISPKT WT006E7034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e7034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 0
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:048:05:46:00.467 5661638 ACISPKT RS_0000001
2024:048:05:46:04.467 5661653 ACISPKT RH_0000001
2024:048:05:46:27.467 5661743 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 26567
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6 is WT006E7034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,26567,OORMPEN,CSELFMT2,ENAB)
2024:048:08:49:54.467 5704697 ACISPKT AA00000000
==> ACIS integration time of 11.01 ks.
This is 104.83% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:048:08:52:54.467 5705400 MP_OBSID 43695
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 43695:
No ocat info found for obsid 43695
2024:048:09:14:37.325 5710484 MP_OBSID 29269
LATEST OCAT INFO FOR OBSID 29269:
Target Name: AGC 721931 SI Mode: TE_00972
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 15.1 Remaining Exposure time: 15.1
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: F Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:048:09:14:37.325 5710484 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:048:09:16:36.725 5710950 SIMFOCUS -418
2024:048:09:17:56.125 5711260 SIMFOCUS -468
2024:048:09:32:40.299 5714710 ACISPKT AA00000000
2024:048:09:32:44.299 5714726 ACISPKT AA00000000
2024:048:09:32:48.299 5714742 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:048:09:33:12.299 5714835 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:048:09:34:15.299 5715081 ACISPKT WT00972024
ACIS PBLOCK LOADS:
parameterBlockId = 0x00972024
fepCcdSelect = 10 7 6 10 10 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:048:09:34:19.299 5715097 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29269
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00972B is WT00972024 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29269,OORMPEN,CSELFMT2,ENAB)
2024:048:09:34:23.299 5715112 ACISPKT RS_0000001
2024:048:09:34:27.299 5715128 ACISPKT RH_0000001
2024:048:13:25:01.285 REAL-TIME COMM BEGINS 2024:048:08:25:01.285 EST
2024:048:14:27:03.454 5783640 ACISPKT AA00000000
==> ACIS integration time of 16.59 ks.
This is 109.88% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:048:14:27:03.454 5783640 SIMTRANS -99616 (HRC-S)
2024:048:14:30:03.454 5784342 COMMAND_HW CSELFMT6
2024:048:14:30:03.454 5784342 MP_OBSID 43694
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 43694:
No ocat info found for obsid 43694
2024:048:14:30:37.793 5784476 COMMAND_SW 4OHETGIN
2024:048:14:32:40.854 5784956 COMMAND_SW OORMPDS
==>The requested SI_MODE for the inbound CTI is TE_007AE
2024:048:14:32:40.854 5784956 ACISPKT AA00000000
2024:048:14:32:44.854 5784972 ACISPKT AA00000000
2024:048:14:32:48.854 5784988 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:048:14:33:12.854 5785081 ACISPKT WSPOW3F03F
==> WSPOW COMMAND LOADS: All Feps; std S array
2024:048:14:34:15.854 5785327 ACISPKT WT007AE024
ACIS PBLOCK LOADS:
parameterBlockId = 0x007ae024
fepCcdSelect = 9 7 5 6 4 8
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 32
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3750
windowSlotIndex = 65535
2024:048:14:34:19.854 5785343 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 43694
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_007AEB is WT007AE024 and is stored.
>>>ERROR: WE ARE DOING A CTI MEASUREMENT BUT WE ARE NOT IN FMT 2!
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-IN,LETG-OUT,43694,OORMPDS,CSELFMT6,ENAB)
2024:048:14:34:21.254 5785348 COMMAND_HW CSELFMT2
2024:048:14:34:23.854 5785358 ACISPKT RS_0000001
2024:048:14:34:27.854 5785374 ACISPKT RH_0000001
2024:048:14:55:01.285 REAL-TIME COMM ENDS 2024:048:09:55:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:048:15:38:03.780 5800265 MP_OBSID 43693
==> ObsID change occurs 65.3 minutes after stop science.
LATEST OCAT INFO FOR OBSID 43693:
No ocat info found for obsid 43693
2024:048:16:51:26.992 5817449 MP_OBSID 43692
LATEST OCAT INFO FOR OBSID 43692:
No ocat info found for obsid 43692
2024:048:17:16:20.854 5823278 ACISPKT AA00000000
==> ACIS integration time of 8.32 ks.
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
2024:048:17:19:20.854 5823981 ACISPKT AA00000000
2024:048:17:19:20.854 5823981 ORBPOINT EEF1000
==> Entry leg pad time is 10.00 ks.
AE-8 EVENTS TIME CHECK:
from backstop: EE1RADZ0 = 048:17:19:20
from CRM file: EE1RADZ0 = 048:17:19:20
==> CRM Pad Time: 10 ks and Backstop Pad Time: 10.00 ks agree.
2024:048:17:19:29.854 5824016 ACISPKT WSPOW0002A
==> WSPOW COMMAND LOADS: Feps 1 3 5; All vids down
2024:048:17:20:32.854 5824262 ACISPKT RS_0000001
2024:048:20:26:00.000 5867685 MP_OBSID 43691
LATEST OCAT INFO FOR OBSID 43691:
No ocat info found for obsid 43691
2024:048:20:52:31.569 5872910 ORBPOINT EPERIGEE
>>>ERROR: Time delta between EE1RADZ0/EEF1000 and EPERIGEE is less than 4.0 hrs.
2024:048:21:15:50.000 5879353 MP_OBSID 43690
LATEST OCAT INFO FOR OBSID 43690:
No ocat info found for obsid 43690
2024:048:22:27:36.029 5896157 MP_OBSID 43689
LATEST OCAT INFO FOR OBSID 43689:
No ocat info found for obsid 43689
2024:049:00:15:20.854 5921386 ACISPKT RBTXINGBLL
2024:049:00:25:20.854 5923727 ACISPKT AA00000000
2024:049:00:25:20.854 5923727 ORBPOINT XEF1000
==> The requested SI_MODE for the outbound CTI is TE_00B26
2024:049:00:25:24.854 5923743 ACISPKT AA00000000
2024:049:00:25:28.854 5923758 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:049:00:25:52.854 5923852 ACISPKT WSPOW0AF3F
==> WSPOW COMMAND LOADS: All Feps; I0 I1 I2 I3 S1 S3
2024:049:00:26:55.854 5924098 ACISPKT WT00B26014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00b26014
fepCcdSelect = 3 7 0 1 2 5
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 32
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3750
windowSlotIndex = 65535
2024:049:00:26:59.854 5924113 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 43689
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00B26B is WT00B26014 and is stored.
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-IN,LETG-OUT,43689,OORMPDS,CSELFMT2,ENAB)
2024:049:00:27:03.854 5924129 ACISPKT RS_0000001
2024:049:00:27:07.854 5924145 ACISPKT RH_0000001
2024:049:01:41:22.011 5941527 COMMAND_HW CSELFMT6
>>>ERROR: CHANGE FROM FMT2 OCCURS BEFORE A STOP SCIENCE!
2024:049:01:41:56.350 5941661 COMMAND_SW 4OHETGRE
2024:049:01:45:39.811 5942533 COMMAND_HW CSELFMT2
2024:049:01:49:13.610 5943367 ACISPKT AA00000000
==> ACIS integration time of 0.44 ks.
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
2024:049:01:52:12.610 5944066 COMMAND_SW OORMPEN
==> Exit leg pad time is 5.21 ks.
AE-8 EVENTS TIME CHECK:
from backstop: XE1RADZ0 = 049:00:25:20
from CRM file: XE1RADZ0 = 049:00:25:20
==> CRM Pad Time: 5.213 ks and Backstop Pad Time: 5.21 ks agree.
2024:049:01:52:13.610 5944070 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:049:01:52:13.610 5944070 ACISPKT AA00000000
2024:049:01:52:14.610 5944073 MP_OBSID 28117
==> ObsID change occurs 0.0 minutes after stop science.
>>>ERROR: ObsID change occurs less than 3 minutes after a stop science command.
LATEST OCAT INFO FOR OBSID 28117:
Target Name: IC559 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 9 Remaining Exposure time: 9
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 25 Obj_Flag: NO
2024:049:01:52:17.610 5944085 ACISPKT AA00000000
2024:049:01:52:21.610 5944101 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:049:01:52:45.610 5944194 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:049:01:53:48.610 5944440 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:049:01:53:52.610 5944456 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 28117
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,28117,OORMPEN,CSELFMT2,ENAB)
2024:049:01:53:56.610 5944471 ACISPKT RS_0000001
2024:049:01:54:00.610 5944487 ACISPKT RH_0000001
2024:049:01:58:14.010 5945476 SIMFOCUS -536
2024:049:03:10:01.285 REAL-TIME COMM BEGINS 2024:48:22:10:01.285 EST
2024:049:04:40:01.285 REAL-TIME COMM ENDS 2024:48:23:40:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:049:04:44:30.610 5984409 ACISPKT AA00000000
==> ACIS integration time of 9.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:049:04:47:30.610 5985111 MP_OBSID 29276
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29276:
Target Name: Abell 370 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 25 Obj_Flag: NO
2024:049:05:22:08.909 5993222 ACISPKT WSVIDALLDN
2024:049:05:22:26.909 5993292 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:049:05:23:29.909 5993538 ACISPKT WT006E7034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e7034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 0
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:049:05:23:33.909 5993554 ACISPKT RS_0000001
2024:049:05:23:37.909 5993569 ACISPKT RH_0000001
2024:049:05:24:00.909 5993659 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29276
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6 is WT006E7034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,29276,OORMPEN,CSELFMT2,ENAB)
2024:049:08:10:47.909 6032711 ACISPKT AA00000000
==> ACIS integration time of 10.01 ks.
This is 100.07% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:049:08:10:47.909 6032711 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:049:08:12:47.309 6033177 SIMFOCUS -418
2024:049:08:13:47.909 6033413 MP_OBSID 29262
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29262:
Target Name: SDSSJ091424.76+115625.6 SI Mode: TE_0057A
Instrument: ACIS-S Grating: NONE Type: CCT
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:049:08:14:06.709 6033487 SIMFOCUS -468
2024:049:08:30:24.080 6037301 ACISPKT AA00000000
2024:049:08:30:28.080 6037316 ACISPKT AA00000000
2024:049:08:30:32.080 6037332 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:049:08:30:56.080 6037426 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:049:08:31:59.080 6037671 ACISPKT WT0057A034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0057a034
fepCcdSelect = 10 7 6 10 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:049:08:32:03.080 6037687 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29262
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0057AB is WT0057A034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29262,OORMPEN,CSELFMT2,ENAB)
2024:049:08:32:07.080 6037703 ACISPKT RS_0000001
2024:049:08:32:11.080 6037718 ACISPKT RH_0000001
2024:049:11:15:01.285 REAL-TIME COMM BEGINS 2024:049:06:15:01.285 EST
2024:049:11:26:35.080 6078553 ACISPKT AA00000000
==> ACIS integration time of 9.50 ks.
This is 95.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:049:11:26:35.080 6078553 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:049:11:28:34.480 6079019 SIMFOCUS -536
2024:049:11:29:35.080 6079256 MP_OBSID 29277
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29277:
Target Name: Abell 370 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 25 Obj_Flag: NO
2024:049:11:41:45.259 6082105 ACISPKT AA00000000
2024:049:11:41:49.259 6082121 ACISPKT AA00000000
2024:049:11:41:53.259 6082136 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:049:11:42:17.259 6082230 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:049:11:43:20.259 6082476 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:049:11:43:24.259 6082492 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29277
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,29277,OORMPEN,CSELFMT2,ENAB)
2024:049:11:43:28.259 6082507 ACISPKT RS_0000001
2024:049:11:43:32.259 6082523 ACISPKT RH_0000001
2024:049:12:45:01.285 REAL-TIME COMM ENDS 2024:049:07:45:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:049:14:50:42.259 6126347 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:049:14:50:42.259 6126347 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:049:14:52:41.659 6126813 SIMFOCUS -418
2024:049:14:53:42.259 6127050 MP_OBSID 29261
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 29261:
Target Name: SDSSJ093756.18+104808.2 SI Mode: TE_0057A
Instrument: ACIS-S Grating: NONE Type: CCT
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:049:14:54:01.059 6127123 SIMFOCUS -468
2024:049:15:11:52.972 6131306 ACISPKT AA00000000
2024:049:15:11:56.972 6131322 ACISPKT AA00000000
2024:049:15:12:00.972 6131337 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:049:15:12:24.972 6131431 ACISPKT WSPOW0C006
==> WSPOW COMMAND LOADS: Feps 1 2; S2 S3
2024:049:15:13:27.972 6131677 ACISPKT WT0057A034
ACIS PBLOCK LOADS:
parameterBlockId = 0x0057a034
fepCcdSelect = 10 7 6 10 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 30
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:049:15:13:31.972 6131692 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29261
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_0057AB is WT0057A034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,29261,OORMPEN,CSELFMT2,ENAB)
2024:049:15:13:35.972 6131708 ACISPKT RS_0000001
2024:049:15:13:39.972 6131724 ACISPKT RH_0000001
2024:049:18:08:03.972 6172559 ACISPKT AA00000000
==> ACIS integration time of 9.50 ks.
This is 95.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:049:18:11:03.972 6173261 MP_OBSID 43688
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 43688:
No ocat info found for obsid 43688
2024:049:18:36:19.297 6179175 MP_OBSID 29263
LATEST OCAT INFO FOR OBSID 29263:
Target Name: Swift J1728.9-3613 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GO
Exposure Time: 9.5 Remaining Exposure time: 9.5
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:049:18:36:19.297 6179175 SIMTRANS 92904 (ACIS-I)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2024:049:18:38:18.697 6179641 SIMFOCUS -536
2024:049:18:49:13.860 6182197 ACISPKT AA00000000
2024:049:18:49:17.860 6182213 ACISPKT AA00000000
2024:049:18:49:21.860 6182229 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2024:049:18:49:45.860 6182322 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:049:18:50:48.860 6182568 ACISPKT WT006E6034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e6034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:049:18:50:52.860 6182584 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 29263
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6B is WT006E6034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,29263,OORMPEN,CSELFMT2,ENAB)
2024:049:18:50:56.860 6182599 ACISPKT RS_0000001
2024:049:18:51:00.860 6182615 ACISPKT RH_0000001
2024:049:19:35:01.285 REAL-TIME COMM BEGINS 2024:049:14:35:01.285 EST
2024:049:21:05:01.285 REAL-TIME COMM ENDS 2024:049:16:05:01.285 EST
==> COMM DURATION: 90.00 mins.
2024:049:21:58:10.860 6226439 ACISPKT AA00000000
==> ACIS integration time of 10.00 ks.
This is 105.26% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2024:049:22:01:10.860 6227142 MP_OBSID 27415
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 27415:
Target Name: NGC 2353 SI Mode: TE_006E6
Instrument: ACIS-I Grating: NONE Type: GTO
Exposure Time: 15 Remaining Exposure time: 15
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: YYYY NNNNNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither: Y
Y Amp: 0.004444 deg Y Freq: 0.254600 deg/sec Y Phase: 0
Z Amp: 0.004444 deg Z Freq: 0.180000 deg/sec Z Phase: 0
Cycle: 24 Obj_Flag: NO
2024:049:22:40:24.736 6236328 ACISPKT WSVIDALLDN
2024:049:22:40:42.736 6236398 ACISPKT WSPOW00F1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I0 I1 I2 I3
2024:049:22:41:45.736 6236644 ACISPKT WT006E7034
ACIS PBLOCK LOADS:
parameterBlockId = 0x006e7034
fepCcdSelect = 10 3 2 1 0 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 0
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2024:049:22:41:49.736 6236659 ACISPKT RS_0000001
2024:049:22:41:53.736 6236675 ACISPKT RH_0000001
2024:049:22:42:16.736 6236765 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 27415
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_006E6 is WT006E7034 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-I,HETG-OUT,LETG-OUT,27415,OORMPEN,CSELFMT2,ENAB)
2024:050:02:35:43.736 6291426 ACISPKT AA00000000
==> ACIS integration time of 14.01 ks.
This is 93.38% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-- CHANDRA LOAD END --
************************
ACIS LOAD REVIEW SUMMARY
************************
THERE ARE 18 REAL-TIME COMM PASSAGES IN THIS LOAD.
FREQUENCY OF ACIS COMMAND OCCURRENCES TABLE:
----------------------------------------------------------------------
OBSIDs WSVIDALLDNs RS_0000001 RH_0000001 X[TC]Z0000005 AA00000000
----------------------------------------------------------------------
63 44 44 41 41 114
**NOTE: There are 3 perigee crossings in this load.
FREQUENCY OF OTG INSERTIONS/RETRACTIONS:
--------------------------------------------
LETG_INs LETG_REs HETG_INs HETG_REs
--------------------------------------------
0 0 5 6
--------------------------------------------------------------------------
--------------------------------------------------------------------------
--------------------------------------------------------------------------
AT LEAST ONE INSTANCE OF THE FOLLOWING TYPES OF WARNINGS OR ERRORS WERE ENCOUNTERED:
o. Either Radmon was NOT ENABLED at least 15 ks after an electron 1 exit.
-OR- Radmon was NOT enabled after electron 1 exit.
o. The radzone ACIS commanding triplet was not seen.
o. Time difference between a WSVIDALLDN command and the 2nd AA00000000 that precedes it is greater than 10 mins.
o. RADMON occured more than 3.25 minutes AFTER stop science.
o. There is a SIM translation that occurs DURING an ACIS science run.
o. The OBSID change to 27141 that occurs less than 3 mins after a stop science.
o. RadMon was disabled prior to radbelt transit but we were NOT at HRC-S yet.
o. The OBSID change to 27146 that occurs less than 3 mins after a stop science.
o. There is a change from FMT2 before an ACIS stop science.
o. The OBSID change to 28117 that occurs less than 3 mins after a stop science.
--------------------------------------------------------------------------
ACIS LOAD REVIEW FAILED