ECS Measurement SI Mode Trends



Statistics Run Date: 2018Jan08

  1. Introduction
  2. Rolling Monthly
  3. Since Start of Current Epoch
  4. Since Mid 2012
  5. Important Notes

I. Intro

This web page will help you track ECS measurement performance with regard to
total time on each of the three SI modes as well as the amount of the total time that
was cold (i.e. temperatures <= -118.7 degress C).


The present targets for the Total and Cold times are:

    Total time per SI Mode per measurement: 7600.0 seconds
    Fraction of total time the measurement should be cold: 60.0%
Back To Top

II. Rolling Monthly

Total ECS Time:

ECS Trending Table: Total Time
Stats TE_007AC TE_007AE TE_00B26
Total Expected Time (secs) 53200 53200 76000
Total Actual Time (secs) 62033 55700 81398
Delta From Expected (secs) 8833.00 2500.00 5399.00
% of Expected Total (secs) 116.60% 104.70% 107.10%

Cold ECS Time:

ECS Trending Table: Cold Time
Stats TE_007AC TE_007AE TE_00B26
Total Exp. Cold Time (secs) 31920.0 31920.0 45600.0
Total Actual Cold Time (secs) 5068 15250 18700
Delta From Expected (secs) -26851.89 -16669.79 -26899.13
% of Exp. Cold Total (secs) 15.88% 47.78% 41.01%


ECS Trending Table: SI Mode Stats
SI Mode Total Number of Obs. Total Exposure Time (sec) Average Exposure (sec/obs)
Primary 6 Chip SI Modes
TE_007AC 4 35241.00 8810.25
TE_007AE 3 22981.00 7660.33
TE_00B26 7 57959.00 8279.86
Old 6 Chip SI Modes
TE_00216 0 0.00 0.00
TE_0021C 0 0.00 0.00
TE_008EA 0 0.00 0.00
5 Chip SI Modes
TE_00C60 6 50232.00 8372.00
TE_00CA8 4 32719.00 8179.75
4 Chip SI Modes
TE_00C62 0 0.00 0.00


Back To Top

III. Statistics Since the Start of the Current Epoch

Total ECS Time:

ECS Trending Table: Total Time
Stats TE_007AC TE_007AE TE_00B26
Total Expected Time (secs) 114000 114000 167200
Total Actual Time (secs) 137760 132635 194743
Delta From Expected (secs) 23760.00 18635.00 27543.00
% of Expected Total (secs) 120.84% 116.35% 116.47%

Cold ECS Time:

ECS Trending Table: Cold Time
Stats TE_007AC TE_007AE TE_00B26
Total Exp. Cold Time (secs) 68400.0 68400.0 100320.0
Total Actual Cold Time (secs) 27383 43056 63711
Delta From Expected (secs) -41016.61 -25343.08 -36608.82
% of Exp. Cold Total (secs) 40.03% 62.95% 63.51%


ECS Trending Table: SI Mode Stats
SI Mode Total Number of Obs. Total Exposure Time (sec) Average Exposure (sec/obs)
Primary 6 Chip SI Modes
TE_007AC 11 100989.00 9180.82
TE_007AE 10 90199.00 9019.90
TE_00B26 17 153036.00 9002.12
Old 6 Chip SI Modes
TE_00216 0 0.00 0.00
TE_0021C 0 0.00 0.00
TE_008EA 0 0.00 0.00
5 Chip SI Modes
TE_00C60 9 78478.00 8719.78
TE_00CA8 5 42436.00 8487.20
4 Chip SI Modes
TE_00C62 0 0.00 0.00


Back To Top

IV. Statistics Since Mid 2012

Total ECS Time:

ECS Trending Table: Total Time
Stats TE_007AC TE_007AE TE_00B26
Total Expected Time (secs) 3708800 3678400 3708800
Total Actual Time (secs) 4066641 3968634 4110404
Delta From Expected (secs) 357841.52 290234.04 401604.65
% of Expected Total (secs) 109.65% 107.89% 110.83%

Cold ECS Time:

ECS Trending Table: Cold Time
Stats TE_007AC TE_007AE TE_00B26
Total Exp. Cold Time (secs) 2225280.0 2207040.0 2225280.0
Total Actual Cold Time (secs) 1999322 1951415 1913377
Delta From Expected (secs) -225957.68 -255624.65 -311902.40
% of Exp. Cold Total (secs) 89.85% 88.42% 85.98%


ECS Trending Table: SI Mode Stats
SI Mode Total Number of Obs. Total Exposure Time (sec) Average Exposure (sec/obs)
Primary 6 Chip SI Modes
TE_007AC 481 3971083.52 8255.89
TE_007AE 477 3910388.04 8197.88
TE_00B26 480 3936025.93 8200.05
Old 6 Chip SI Modes
TE_00216 5 478338.25 95667.65
TE_0021C 0 0.00 0.00
TE_008EA 0 0.00 0.00
5 Chip SI Modes
TE_00C60 12 102410.00 8534.17
TE_00CA8 7 58246.00 8320.86
4 Chip SI Modes
TE_00C62 3 167526.73 55842.24


Back To Top





Important Notes:

A word about the TOTAL Time stats:

    - The Total Expected Time values in the table below is calculated by taking the number of actual observations for each SI Mode and multiplying it by 7600.0.
    - Total Actual Time is the sum of all actual ECS measurement time for each of the three SI Modes.
    - % Expected Total is the fraction of the expected that we actually achieved, or:

         (Total Actual Time / Total Expected Time) * 100.0

A word about the COLD Time stats:

    - The Total Expected Cold Time value in the table below is 60.0% of the Total Expected Time (see Table above).
    - Total Actual Cold Time is the sum of all time during each measurement where the temperature was <= -118.7 degrees C
    - % of Expected Total is the fraction of the Total Expected Time achieved

SI Mode Mapping between 6,5 and 4 chip modes:

    The 6 chip SI Modes consist of three distinct modes. But there are only 2, 5 chip SI Modes and only one 4 chip SI mode. To make tracking feasible, the 4 and 5 chip modes were mapped into the 6 chip modes in the following manner:

     6 chip 5 chip 4 chip

    TE_007AC -> TE_00C60 TE_00C62

    TE_00B26 -> TE_00C60 TE_00C62

    TE_007AE -> TE_00CA8

All of the TE_00CA8s get counted as TE_007AE

Half of the TE_00C60s get counted towards TE_007AC and the other half get counted with the TE_00B26s

Half of the TE_00C62s get counted towards TE_007AC and the other half get counted with the TE_00B26s.

So watchout for TE_00B26 over-representation.

Back To Top