The present targets for the Total and Cold times are:
Total time per SI Mode per measurement: 7600.0 seconds
Fraction of total time the measurement should be cold: 60.0%
II. Statistics Since the Start of the Current Epoch
Cold Time Statistics:
NOTICE!!!! We have switched to 6 month epochs!!!
The epochs start on the following Days of the Year: 001, 181
WARNING!!!! Cold Time Statistics SERIOUSLY Out Of Balance!
(See the Rule Set at the bottom of the page)
Stats | TE_007AC | TE_007AE | TE_00B26 |
---|---|---|---|
Total Exp. Cold Time (secs) | 145920 | 145920 | 145920 |
Total Actual Cold Time (secs) | 101959 | 56809 | 65818 |
Delta From Expected (secs) | -43960 | -89110 | -80101 |
% of Exp. Cold Total (secs) | 69.87% | 38.93% | 45.11% |
Stats | TE_007AC | TE_007AE | TE_00B26 |
---|---|---|---|
Total Expected Time (secs) | 243200 | 243200 | 243200 |
Total Actual Time (secs) | 254512 | 246918 | 186443 |
Delta From Expected (secs) | 11312 | 3718 | -56756 |
% of Expected Total (secs) | 104.65% | 101.53% | 76.66% |
SI Mode | Total Number of Obs. | Total Exposure Time (sec) | Average Exposure (sec/obs) | Primary 6 Chip SI Modes | TE_007AC | 32 | 231072.00 | 7221.00 |
---|---|---|---|
TE_007AE | 27 | 199101.00 | 7374.11 |
TE_00B26 | 24 | 156491.00 | 6520.46 | Old 6 Chip SI Modes | TE_00216 | 0 | 0.00 | 0.00 |
TE_0021C | 0 | 0.00 | 0.00 |
TE_008EA | 0 | 0.00 | 0.00 | 5 Chip SI Modes | TE_00C60 | 7 | 53393.00 | 7627.57 |
TE_00CA8 | 6 | 47817.00 | 7969.50 | 4 Chip SI Modes | TE_00C62 | 0 | 0.00 | 0.00 | Totals: | 96 | 687874.00 | 7165.35 |
All of the TE_00CA8s get counted as TE_007AE So watchout for TE_00B26 over-representation. A word about the Total Time stats:
- The Total Expected Time values for each SI mode in the table is calculated by:
# of ECS runs executed in this epoch so far * 10,000.0 * 0.76 / 3.0
Where:
10,000.0 seconds is the maximum possible time for ECS runs
We exepct only 7600.0 seconds on average - hence multiply by 0.76
We divide by three because we want the time evenly distributed across all three aggregate SI modes
A word about the COLD Time stats:
Cold Time is defiined by focal plane temperatures <= -118.7 degrees C:
The Total Expected Cold Time value is 60.0% of the Total Expected Time (see above).
SI Mode Mapping between 6,5 and 4 chip modes:
The 6 chip SI Modes consist of three distinct modes. But there are only 2, 5 chip SI Modes and only one 4 chip SI mode. To make tracking feasible, the 4 and 5 chip modes were mapped into the 6 chip modes in the following manner:
6 chip 5 chip 4 chip
TE_007AC -> TE_00C60 TE_00C62
TE_00B26 -> TE_00C60 TE_00C62
TE_007AE -> TE_00CA8
Half of the TE_00C60s get counted towards TE_007AC and the other half get counted with the TE_00B26s
Half of the TE_00C62s get counted towards TE_007AC and the other half get counted with the TE_00B26s.
Back To Top