The present targets for the Total and Cold times are:
Total time per SI Mode per measurement: 7600.0 seconds
Fraction of total time the measurement should be cold: 60.0%
II. Statistics Since the Start of the Current Epoch
Cold Time Statistics:
NOTICE!!!! We have switched to 6 month epochs!!!
The epochs start on the following Days of the Year: 032, 213
Stats | TE_007AC | TE_007AE | TE_00B26 |
---|---|---|---|
Total Exp. Cold Time (secs) | 42559 | 42559 | 42559 |
Total Actual Cold Time (secs) | 19327 | 4726 | 7026 |
Delta From Expected (secs) | -23231 | -37832 | -35532 |
% of Exp. Cold Total (secs) | 45.41% | 11.10% | 16.51% |
Stats | TE_007AC | TE_007AE | TE_00B26 |
---|---|---|---|
Total Expected Time (secs) | 70933 | 70933 | 70933 |
Total Actual Time (secs) | 62976 | 48995 | 84342 |
Delta From Expected (secs) | -7957 | -21938 | 13409 |
% of Expected Total (secs) | 88.78% | 69.07% | 118.90% |
SI Mode | Total Number of Obs. | Total Exposure Time (sec) | Average Exposure (sec/obs) | Primary 6 Chip SI Modes | TE_007AC | 9 | 62976.00 | 6997.33 |
---|---|---|---|
TE_007AE | 8 | 48995.00 | 6124.38 |
TE_00B26 | 6 | 37520.00 | 6253.33 | Old 6 Chip SI Modes | TE_00216 | 0 | 0.00 | 0.00 |
TE_0021C | 0 | 0.00 | 0.00 |
TE_008EA | 0 | 0.00 | 0.00 | 5 Chip SI Modes | TE_00C60 | 3 | 27388.00 | 9129.33 |
TE_00CA8 | 0 | 0.00 | 0.00 | 4 Chip SI Modes | TE_00C62 | 2 | 19434.00 | 9717.00 | Totals: | 28 | 196313.00 | 7011.18 |
Rule #1: The key time period for balancing SI mode statistics is the 6 month Epoch By the end of the epoch, the SI mode statistics should match the rules stated below. Rule #2: Each of the three, default, 6 chip, SI modes (or their 5 chip equivalents) must be used at least once in each load week. - If two SI modes are lagging in either cold time or total time, apportion the week's ECS measurements between the two of them roughly commensurate with the amount they are lagging. - The 6 month Epoch allows "even" correction of two lagging SI modes. No need to pile a weeks worth of ECS measurements on one SI mode if two are lagging. Rule #3: Make certain to spread the amount of COLD ECS time as evenly as possible across all three SI modes Balance Cold measurement data between the three default 6-chip modes within 10% of each other on an Epoch basis
Rule #4: Spread the amount of *Total* ECS time as evenly as possible across all three SI modes.
- Balance Total measurement data between the three default 6-chip modes within 10% of each other on an Epoch basis.
Rule #3 takes precedence over Rule #4.
Rule #5:At least 60% of scheduled ECS measurement time must be -118.7degC
Rule #6: Any ECS measurements during a Perigee Passage that are cold MUST be assigned to the nominal ECS run SI modes. i.e. Any requested Rawmode runs can be done with a warm focal plane.
All of the TE_00CA8s get counted as TE_007AE So watchout for TE_00B26 over-representation. A word about the Total Time stats:
- The Total Expected Time values for each SI mode in the table is calculated by:
# of ECS runs executed in this epoch so far * 10,000.0 * 0.76 / 3.0
Where:
10,000.0 seconds is the maximum possible time for ECS runs
We exepct only 7600.0 seconds on average - hence multiply by 0.76
We divide by three because we want the time evenly distributed across all three aggregate SI modes
A word about the COLD Time stats:
Cold Time is defiined by focal plane temperatures <= -118.7 degrees C:
The Total Expected Cold Time value is 60.0% of the Total Expected Time (see above).
SI Mode Mapping between 6,5 and 4 chip modes:
The 6 chip SI Modes consist of three distinct modes. But there are only 2, 5 chip SI Modes and only one 4 chip SI mode. To make tracking feasible, the 4 and 5 chip modes were mapped into the 6 chip modes in the following manner:
6 chip 5 chip 4 chip
TE_007AC -> TE_00C60 TE_00C62
TE_00B26 -> TE_00C60 TE_00C62
TE_007AE -> TE_00CA8
Half of the TE_00C60s get counted towards TE_007AC and the other half get counted with the TE_00B26s
Half of the TE_00C62s get counted towards TE_007AC and the other half get counted with the TE_00B26s.
Back To Top