NIL SI MODES


NIL SI mode

As of Februrary 2024, this is the new NIL SI mode, which uses a standard TE mode plus a window blocking all events to allow txings information to be telemetered in the exposure records.
NIL SI mode
SIMODE # of CCDs Parameter Block Window Block
H2C_00022WT00DAA014W200138014

Historical NIL SI modes

(valid Nov 2022 - Feb 2024)
These are the new next-in-line modes for use during HRC observations. We are no longer switching between different modes for HRC-I and HRC-S, or for even/odd ObsIDs. All observations should use the 2-chip mode, unless thermal conditions require 1-chip.
NIL SI modes
SIMODE # of CCDs Parameter Block Window Block
H2C_00012WT00D96014NONE
H1C_00011WT00D98014NONE


(valid pre November 2022)
How to decode the first three letters of the SIMODE

"H[IS][EO]]"

H - HRC

[IS] - I: HRC-I S:HRC-S

[EO] - E: OBSID is even O: OBSID is odd

5-chip NIL modes
SIMODE SIM Position Parameter Block Window Block
HIE_0002HRC-IWT00452024NONE
HIO_0002HRC-IWT00452024NONE
HSE_0002HRC-SWT0023C024 W200039014 bottom 200 rows
HSO_0002HRC-SWT0023A024W200038014 top 200 rows


4-chip NIL modes
SIMODE SIM Position Parameter Block Window Block
HIE_0003HRC-IWT00D06014NONE
HIO_0003HRC-IWT00D06014NONE
HSE_0003HRC-SWT00D0A014W200133014 bottom 200 rows
HSO_0003HRC-SWT00D08014W200132014 top 200 rows

    Last updated: 01/17/24