AXAF Standard Operating Procedure |
DATE: 07/19/99 REV: 3.1
SOP_61033_DEAA_OFF.doc |
PROCEDURE: deaa_off.ps rev 2.0
61033.1 OVERVIEW
This is an "atomic" procedure which simply powers off the DEA side A .
61033.2 SUPPORT SUMMARY
SUMMARY |
Disable and turn off DEA power supply side A |
CONSTRAINTS |
Requires FMT 1,2,4, or 6 Video boards are off Not in bakeout |
INITIAL CONDITIONS |
Assumes that the PSMC has power from the spacecraft |
Author: A. Northrup |
EST. Time : 00:01
|
AXAF Standard Operating Procedure |
DATE: 07/19/99 REV: 3.1
SOP_61033_DEAA_OFF.doc |
DISPLAYS |
F_OPERATIONS_COMMAND I_ACIS_E_NEW |
COMPS | None |
COMMAND GROUPS | None |
PIX MAPS | None |
COMMAND LOADS | None |
SCRIPTS | I_1_DEAA_OFF |
A. Set the following command system configuration parameters:
Clear To Send Mechanism | = FSV |
CAR Processing | = Enabled |
FSV Processing | = Enabled |
CRR Processing | = Disabled |
Output Format | = NRZM |
Minimum Time Delay (sec) | = 3 |
CAR Time-out (sec) | = 40 |
FSV Time-out (sec) | = 45 |
Blocking Factor | = 90 |
Burst Factor | = 1 |
A. SOT authorizes OC to start script I_1_DEAA_OFF.
B. OC may resume past initial wait.
Script uplinks command
1DEPSAOF {1.1}
Script uplinks command
1DEPSADS {1.2}
[Disable DEA A]
C. OC informs SOT that script has completed.
D. Verify telemetry:
|
|
|
|
DEA A Enable |
|
|
|
DEA A On |
|
|
|
DEA Input V A |
|
|
|
DEA Input I A |
|
|
|
DEA +24 V A |
|
|
|
DEA +6 V A |
|
|
|
DEA -6 V A |
|
|
|
DEA +15 V A |
|
|
|
DEA -15 V A |
|
|
|
DEA +28 V A |
|
|
|
Author: A. Northrup |
EST. Time : 00:01
|