AXAF Standard Operating Procedure
DATE: 7/19/99              REV: 3.1

SOP_61037_DPAB_ON.doc

PURPOSE:  Turn on the DPA B.

PARTICIPANTS:  OC/CC, SOT

PROCEDURE:  dpab_on.ps rev 2.0

61037.1   OVERVIEW  

This is an "atomic" procedure which simply powers on the DPA side B .

61037.2   SUPPORT SUMMARY  

SUMMARY
Enable and turn on DPA power supply side B
CONSTRAINTS
Requires FMT 1,2,4, or 6
INITIAL CONDITIONS
Assumes that the PSMC has power from the spacecraft


Author:  A. Northrup
EST. Time :  00:01




DISPLAYS
F_OPERATIONS_COMMAND
I_ACIS_E_NEW
COMPS None
COMMAND GROUPS None
PIX MAPS None
COMMAND LOADS None
SCRIPTS I_1_DPAB_ON

61037.3   CONFIGURE COMMAND SYSTEM

      A.  Set the following command system configuration parameters:

Clear To Send Mechanism   =  FSV
CAR Processing                   =  Enabled
FSV Processing                    =  Enabled
CRR Processing                   =  Disabled
Output Format                       =  NRZM
Minimum Time Delay (sec)   =  3
CAR Time-out (sec)              =  40
FSV Time-out (sec)               =  45
Blocking Factor                     =  90
Burst Factor                          =  1

61037.4   TURN ON DPA B      {1.0}

A. SOT authorizes OC to start script I_1_DPAB_ON.
B. OC may resume past initial wait.

      Script uplinks command
      1DPPSBEN        {1.1}


      [Enable DPA B]

      Script uplinks command
      1DPPSBON        {1.2}
                                 [DPA B ON]

C. OC informs SOT that script has completed.
D. Verify telemetry .

Description
MSID
Value
Script Verification
DPA B Enable
1DPPSBX
ENB
N
DPA B On
1DPPSB
ON
N
DPA +5V
1DPP0AVO
4.0 - 5.5
N
DPA Input V
1DP28AVO
28.0 - 34.0
N
DPA Input I
1DPICACU
0.26 - 0.32
N

END OF PROCEDURE