ACIS OAC Test: switch_bepa_b


Step #
Title 5.8_V2.1 Time Req (m)
Cmd Desc
Cmd Mnem
Cmd EGSE
Seq Key
Tlm Desc
Tlm Mnem
Exp Val
Units
Tlm EGSE
Other Ver
Crit
Desc Notes RT Con
Tlm Fmt
Min Alt
SIM Pos
1.0 Select BEP B
1.1 Select BEP B 1
1BSELICL(1)








1BSELICL=1 selects BEP B
Y 1or2

2.0 Cold Boot BEPs
2.1 Set boot modifier off 1 DPA Boot Modifier 1BMODIBM(0)








disable uplink boot
Y 1or2

2.2 Set warm boot flag off 1 DPA Cold Boot 1WRMBTSB(0)








Cold boot active BEP
Y 1or2

2.3 Halt BEP 1 DPA Command Reset 1RSETIRT(1)








Hold active BEP reset line
Y 1or2

2.4 Restart BEP 1
1RSETIRT(0)








Release BEP reset line
Y 1or2

2.5
Check BEP B Boot 2.0








Check bepStartupMessage:
bepTickCounter < 10; version =11;
warmbootFlag = 0, patchValidFlag =1
Check swHousekeeping messages:
startingBepTickCounter < 10;
endingBepTickCounter=
=startingBepTickCounter+640
version =11

A
A
A
B
B
A


Y
1or2


2.6
Check HW LEDs 2.0




BEP Select
BEP FIFO Not Full
BEP FIFO Not Empty
1STAT4ST
1STAT6ST
1STAT7ST
1
1
0



2
2
2
1 indicates BEP B is selected 1 means FIFO not full 1 means FIFO not empty
Y
1or2


2.7
Check SW LEDs 2.0




BEP initialization
Watchdog boot
Science run status
1STAT3ST
1STAT2ST
1STAT1ST
1STAT0ST
0
1
1
0or1



1
2
2
2
0 means BEP SW is running 1 means no watchdog boot 1 means science idle this bit toggles to indicate BEP is running
Y
1or2



Total Time 11

















Paul Plucinsky