ACIS Flight Command: switch_deaa_b


Step # Title 5.9_V2.2 Time (mins) Cmd Desc Cmd Mnem Cmd EGSE Seq Key Tlm Desc Tlm Mnem Exp Val Units Tlm EGSE Other Ver Crit Desc Notes RT Con Tlm Fmt Min Alt SIM Pos
1 Power Down Video Boards
1.1 Power off video boards 1 changeConfigSetting WSVIDALLDN





Check cmdResult==OK
commandEcho==1541

A

Y 1,2 60k
2 Turn off DEA-A input power
2.1
DEA Power A Off 1
DEA-A Power Off
1DEPSAOF



DEA +24 V A
DEA Input V A
DEA +6 V A
DEA -6 V A
DEA +15 V A
DEA -15 V A
DEA +28 V A
1DEPSA
1DEP2AVO
1DE28AVO
1DEP0AVO
1DEN0AVO
1DEP1AVO
1DEN1AVO
1DEP3AVO
OFF
0.0±0.5
25.0—34.0
0.0±0.5
0.0±0.5
0.0±0.5
0.0±0.5
0.0±0.5

V
V
V
V
V
V
V



1
2
2
2
2
2
2
Ignore if DPA unpowered Powers off DEA and board 11 Expect DEA-A power  0.0 W SF 4.4.2 Y
1,2,4,6
60k

2.2 Disable DEA PS A 1 DEA-A Power Disable 1DEPSADS

DEA A Dis 1DEPSAX DIS



Ignore if DPA unpowered SF 4.4.1 Y 1,2,4,6 60k
3 Verify that DEA-B heaters are off
3.1
Verify heaters off 1




DEA B DH Htr Off
DEA B DH Htr Dis
DEA B Bakeout Off
DEA B Bakeout Dis
1DAHTBON
1DAHTBEN
1DABOBON
1DABOBEN
OFF
DIS
OFF
DIS



1
2
1
2
Verify housing heater is off Verify housing heater disabled Verify bakeout heater is off Verify bakeout heater disabled

1,2,4,6
60k

4 Turn on DEA-B input power
4.1 Enable DEA PS B 1 DEA-B Power Enable 1DEPSBEN

DEA B En 1DEPSBX ENB



Ignore if DPA unpowered
Y 1,2,4,6 60k
4.2
DEA Power B On 1
DEA-B Power On
1DEPSBON



DEA +24 V B
DEA Input V B
DEA Input I B
DEA +6 V B
DEA -6 V B
DEA +15 V B
DEA -15 V B
DEA +28 V B
1DEPSB
1DEP2BVO
1DE28BVO
1DEICBCU
1DEP0BVO
1DEN0BVO
1DEP1BVO
1DEN1BVO
1DEP3BVO
ON
24.0—26.0
25.0—34.0
0.62—0.75
5.6—6.7
-7— -5.7
15.0—17.0
-17.0— -15.0
>26.0

V
V
A
V
V
V
V
V



1
2
2
2
2
2
2
2
Ignore if DPA unpowered Powers on DEA board 12 Expect DEA-B power 21±3 W
Y
1,2,4,6
60k

5 Reboot active BEP
5.1 DPA Boot Modifier 1 DPA Boot Modifier 1BMMODIBM(0)





Disable uplink boot



Y 1,2 60k
5.2 Set warm boot flag on 1 DPA Warm Boot 1WRMBTSB(1)





Warm boot active BEP



Y 1,2 60k
5.3 Halt BEP 1 DPA Command Reset 1RSETIRT(1)





Hold active BEP reset line



Y 1,2 60k
5.4 Restart BEP 1
1RSETIRT(0)





Release BEP reset line



Y 1,2 60k
5.5
Check BEP boot 2




bepStartupMessage
swHousekeeping



version>11
warmbootFlag=1
version>11








5.6
Check HW LEDs 2




BEP select
BEP FIFO not full
BEP FIFO not empty
1STAT4ST
1STAT6ST
1STAT7ST
0
1
0



2
2
2
0 indicates BEP-A is selected 1˙means˙FIFO˙not˙full˙ 1˙means˙FIFO˙not˙empty
Y
Y
Y
1,2"
"1,2"
"1,2
60k
60k
60k

5.7
Check SW LEDs 2




BEP initialization
Watcdog boot
Science run status
1STAT3ST
1STAT2ST
1STAT1ST
1STAT0ST
0
1
1
0 or 1



1
2
2
2
0 means BEP sw is running 1 means no watchdog reboot 1 means science idle this bit toggles to indicate BEP running
Y
Y
Y
Y
1,2"
"1,2"
"1,2"
"1,2
60k
60k
60k
60k

6 Start DEA Interface Housekeeping
6.1 Load Board 11 DEA Hkp 1 loadDeaBlock WD00001024





Check cmdResult==OK
commandEcho==225

B Monitor FP temp and DEA voltages
Y 1,2 60k
6.2 Start DEA Hkp run 1 startDea XDZ0000005





Check cmdResult==OK
commandEcho==18

B If Hkp running, cmdResult==CLOBBERED
Y 1,2 60k
7 Start FP temperature control
7.1 set FP temp to -121^0C 1 changeConfigSetting WSFTNEG123





Check cmdResult==OK
commandEcho==6369

A

Y 1,2 60k
7.2 set FP temp to -120^0C 2 changeConfigSetting WSFTNEG121





Check cmdResult==OK
commandEcho==1220

A

Y 1,2 60k
8 Power video boards from DEA-B
8.1a Set I0,S0 relays to DEA-B 1 changeConfigSetting WS_RELAY_0





Check cmdResult==OK
commandEcho==14429
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.1b Power up I0 1 changeConfigSetting WSPOW00100





Check cmdResult==OK
commandEcho==14439
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.1c Power up S0 1 changeConfigSetting WSPOW01100





Check cmdResult==OK
commandEcho==14440
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.2a Set I1,S1 relays to DEA-B 1 changeConfigSetting WS_RELAY_1





Check cmdResult==OK
commandEcho==14430
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.2b Power up I1 1 changeConfigSetting WSPOW01300





Check cmdResult==OK
commandEcho==14443
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.2c Power up S1 1 changeConfigSetting WSPOW03300





Check cmdResult==OK
commandEcho==14445
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.3a Set I2,S3 relays to DEA-B 1 changeConfigSetting WS_RELAY_2





Check cmdResult==OK
commandEcho==14433
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.3b Power up I2 1 changeConfigSetting WSPOW03700





Check cmdResult==OK
commandEcho==14446
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.3c Power up S3 1 changeConfigSetting WSPOW0B700





Check cmdResult==OK
commandEcho==14448
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.4a Set I3,S2 relays to DEA-B 1 changeConfigSetting WS_RELAY_3





Check cmdResult==OK
commandEcho==14434
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.4b Power up I3 1 changeConfigSetting WSPOW0BF00





Check cmdResult==OK
commandEcho==14451
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.4c Power up S2 1 changeConfigSetting WSPOW0FF00





Check cmdResult==OK
commandEcho==14453
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.5a Set S4,S5 relays to DEA-B 1 changeConfigSetting WS_RELAY_4





Check cmdResult==OK
commandEcho==14436
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.5b Power up S4 1 changeConfigSetting WSPOW1FF00





Check cmdResult==OK
commandEcho==14454
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
8.5c Power up S5 1 changeConfigSetting WSPOW3FF00





Check cmdResult==OK
commandEcho==14457
1DEPSB A Wait 60 secs, then check that 1DEPSB=ON
Y 1,2 60k
9 Power down video boards
9.1 Power off video boards 1 changeConfigSetting WSVIDALLDN





Check cmdResult==OK
commandEcho==1541

A

Y 1,2 60k
9.2 Dump System Config. 1 dumpSysConfig RS_0000001





Check cmdResult==OK
commandEcho==66

B

Y 1,2 60k

Paul Plucinsky