Excessive Antico Shield Rate - Antico Shields Off
Description:
This procedure turns off the anticoincidence shield PMT HV to protect
them in the event of excessive rates. The procedure will send commands
to turn off both PMTs; only one should be on.
Procedure Trigger:
The procedure shall be initiated by the Flight Operations Team if the
antico event rate telemetry exceeds the "red" limit for more than 5
seconds in format 1 or for more than 40 seconds in any other
format. The antico rate telemetry mnemonic for this rate is:
Note: Telemetry mnemonic 2SHEV2RT is not included because
experience gained during the ground test program showed it can
occasionally indicate a red-limit condition when none exists.
This procedure shall also be executed by the Flight Operations Team at
any time at the request of the Science Operations Team.