Dark current calibration summary 2019-07-11

Date (mean): 2019:192:01:07:37
T_ccd (mean): -11.77 C

CCD readouts summary

The table below provides the number of pixels which have the specified number of readouts. This quantifies how many pixels have been excluded either by star masking or because an entire quadrant readout is missing due to lost telemetry.

readoutsn_pixels
6298
72
825924
9107
101022245

The table below summarizes each of the 1024x1024 CCD readouts that were used to create the calibration image. Note that each readout is stitched together from four quadrant readouts that are not synchronous in time. This is reflected in the quad dt column which shows the min and max delta time from the mean.

datequad dt (sec)t_ccdint_time(s)n_masked
2019:185:01:52:39-129 to +71-11.385.0669, 1118, 1041, 1366
2019:185:01:53:20-140 to +70-11.3810.0669, 1119, 1039, 1370
2019:190:13:46:45-129 to +70-13.455.01363, 1263, 1050, 1202
2019:190:13:47:25-140 to +70-13.4510.01363, 1265, 1049, 1203
2019:193:04:17:40-129 to +70-10.805.01249, 1290, 1233, 1120
2019:193:04:18:20-150 to +70-10.8010.01248, 1287, 1234, 1121
2019:195:11:37:40-130 to +69-11.245.02041, 1899, 1822, 2065
2019:195:11:38:20-140 to +69-11.2410.02042, 1900, 1819, 2065
2019:195:22:01:41-129 to +70-11.965.01532, 1086, 1189, 978
2019:195:22:02:21-140 to +70-11.9610.01534, 1081, 1189, 980

Plots (all scaled to -10 C)




Reference information

See the legacy dark current calibration pages for useful information.