Dark current calibration summary 2019-11-26

Date (mean): 2019:330:00:12:55
T_ccd (mean): -9.33 C

CCD readouts summary

The table below provides the number of pixels which have the specified number of readouts. This quantifies how many pixels have been excluded either by star masking or because an entire quadrant readout is missing due to lost telemetry.

readoutsn_pixels
6399
74
831769
9174
101016230

The table below summarizes each of the 1024x1024 CCD readouts that were used to create the calibration image. Note that each readout is stitched together from four quadrant readouts that are not synchronous in time. This is reflected in the quad dt column which shows the min and max delta time from the mean.

datequad dt (sec)t_ccdint_time(s)n_masked
2019:322:13:33:46-128 to +71-7.985.02973, 1907, 1726, 2620
2019:322:13:34:27-149 to +70-7.9810.02969, 1909, 1730, 2617
2019:327:23:51:08-128 to +71-10.735.0890, 1232, 926, 1097
2019:327:23:51:49-149 to +70-10.7310.0889, 1232, 924, 1098
2019:330:12:53:40-128 to +71-9.585.0875, 842, 733, 881
2019:330:12:54:21-149 to +70-9.5810.0875, 842, 735, 882
2019:333:03:31:41-129 to +70-9.975.01525, 1564, 1556, 1899
2019:333:03:32:21-140 to +69-9.9710.01520, 1562, 1556, 1898
2019:335:19:12:39-129 to +70-8.375.02072, 2138, 2777, 2429
2019:335:19:13:19-139 to +71-8.3710.02078, 2136, 2780, 2426

Plots (all scaled to -10 C)




Reference information

See the legacy dark current calibration pages for useful information.