Dark current calibration summary 2020-08-30

Date (mean): 2020:243:07:25:48
T_ccd (mean): -12.85 C

CCD readouts summary

The table below provides the number of pixels which have the specified number of readouts. This quantifies how many pixels have been excluded either by star masking or because an entire quadrant readout is missing due to lost telemetry.

readoutsn_pixels
437
63333
740
89056
9171
101035939

The table below summarizes each of the 1024x1024 CCD readouts that were used to create the calibration image. Note that each readout is stitched together from four quadrant readouts that are not synchronous in time. This is reflected in the quad dt column which shows the min and max delta time from the mean.

datequad dt (sec)t_ccdint_time(s)n_masked
2020:237:22:26:40-128 to +70-11.795.0998, 928, 1095, 1026
2020:237:22:27:20-148 to +71-11.7910.01002, 931, 1099, 1026
2020:238:03:15:41-130 to +70-12.155.01040, 699, 848, 821
2020:238:03:16:21-140 to +70-12.1510.01040, 702, 848, 819
2020:245:20:56:40-128 to +71-12.535.0937, 1017, 792, 666
2020:245:20:57:21-150 to +70-12.5310.0936, 1016, 793, 666
2020:246:03:16:40-129 to +71-13.035.0933, 1016, 793, 674
2020:246:03:17:21-140 to +70-13.0310.0932, 1018, 797, 675
2020:248:11:11:41-129 to +70-14.735.0426, 449, 617, 193
2020:248:11:12:21-140 to +70-14.7310.0427, 451, 616, 195

Plots (all scaled to -10 C)




Reference information

See the legacy dark current calibration pages for useful information.