Back to Top

ACISELECA
Static Version: Max --- Full Range

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
1dahacu -3.719e-049.609e-050.01 +/- 0.08(6.26+/-15.56)e-5AMPDA HEATER CURRENT ANo Violation Check
1dahavo -0.0015.007e-040.01 +/- 0.41(0.00+/-0.00)e0VDETECTOR ASSY. HTRNo Violation Check
1dahhavo -0.0026.965e-040.03 +/- 0.57-(1.88+/-14.05)e-4VDA HOUSING HTR +28V INPUT ANo Violation Check
1de28avo -0.1120.00128.79 +/- 1.25-0.01 +/- 0.02VDEA +28V INPUT ANo Violation Check
1deicacu -0.0134.938e-042.43 +/- 0.41-0.01 +/- 0.01AMPDEA INPUT CURRENT ANo Violation Check
1den0avo 2.899e-042.136e-04-6.10 +/- 0.17-0.00 +/- 0.00VDEA -6V VOLTAGE ANo Violation Check
1den1avo -7.843e-045.615e-04-15.27 +/- 0.46-0.01 +/- 0.01VDEA -15V VOLTAGE ANo Violation Check
1dep0avo -0.0024.379e-056.22 +/- 0.04-0.00 +/- 0.00VDEA +6V VOLTAGE ANo Violation Check
1dep1avo -0.0112.319e-0416.12 +/- 0.21-0.01 +/- 0.01VDEA +15V ANALOG ANo Violation Check
1dep2avo -0.0151.740e-0425.16 +/- 0.19-0.01 +/- 0.00VDEA +24V ANALOG ANo Violation Check
1dep3avo -0.0021.533e-0430.69 +/- 0.13-0.00 +/- 0.00VDEA +28V ANALOG ANo Violation Check
1dp28avo -0.1120.00128.83 +/- 1.25-0.01 +/- 0.02VDPA +28V INPUT ANo Violation Check
1dpicacu -0.0052.526e-041.43 +/- 0.21-0.01 +/- 0.01AMPDPA INPUT CURRENT ANo Violation Check
1dpp0avo -0.0024.125e-055.34 +/- 0.04-0.00 +/- 0.00VDPA +5V ANALOG ANo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Jan 10, 2026
Last Site Modification: Sep 30, 2021