| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1dahbcu | on | -0.026 | 2.742e-04 | 0.38 +/- 0.14 | 0.01 +/- 0.00 | AMP | DA HEATER CURRENT B | No Violation Check | off | -4.415e-04 | 4.913e-05 | 0.00 +/- 0.02 | (0.00+/-0.00)e0 | No Violation Check |
| 1dahbvo | on | -0.357 | 0.004 | 5.11 +/- 1.88 | 0.08 +/- 0.04 | V | DA HEATER VOLTAGE B | No Violation Check | off | -0.006 | 6.593e-04 | 0.02 +/- 0.30 | (0.00+/-0.00)e0 | No Violation Check |
| 1dahhbvo | on | -0.239 | 0.012 | 27.75 +/- 3.27 | -0.07 +/- 0.03 | V | DA HOUSING HEATER INPUT | No Violation Check | off | -0.066 | 0.006 | 0.23 +/- 2.53 | (0.00+/-0.00)e0 | No Violation Check |
| 1de28bvo | -0.110 | 8.085e-04 | 27.71 +/- 1.09 | 0.01 +/- 0.01 | V | DEA +28V INPUT B | No Violation Check | |
| 1deicbcu | -0.146 | 0.022 | 16.11 +/- 18.10 | (1.46+/-4.96)e-4 | AMP | DEA INPUT CURRENT B | No Violation Check | |
| 1den0bvo | -1.828e-04 | 1.446e-04 | -0.20 +/- 0.12 | (5.67+/-3.93)e-4 | V | DEA -6V VOLTAGE B | No Violation Check | |
| 1den1bvo | 0.002 | 3.747e-04 | -0.45 +/- 0.31 | 0.00 +/- 0.00 | V | DEA -15V VOLTAGE B | No Violation Check | |
| 1dep0bvo | -8.025e-04 | 2.259e-05 | 0.01 +/- 0.02 | (4.10+/-4.25)e-4 | V | DEA +6V VOLTAGE B | No Violation Check | |
| 1dep1bvo | -0.002 | 6.103e-05 | 0.03 +/- 0.05 | (3.04+/-11.50)e-4 | V | DEA +15V ANALOG B | No Violation Check | |
| 1dep2bvo | -0.003 | 9.170e-05 | 0.04 +/- 0.08 | (8.30+/-17.09)e-4 | V | DEA +24V ANALOG B | No Violation Check | |
| 1dep3bvo | -0.004 | 1.141e-04 | 0.06 +/- 0.10 | 0.00 +/- 0.00 | V | DEA +28V ANALOG B | No Violation Check | |
| 1dp28bvo | -0.111 | 7.683e-04 | 27.73 +/- 1.07 | 0.01 +/- 0.01 | V | DPA +28V INPUT B | No Violation Check | |
| 1dpicbcu | -0.007 | 3.250e-04 | 0.37 +/- 0.27 | 0.01 +/- 0.01 | AMP | DPA INPUT CURRENT B | No Violation Check | |
| 1dpp0bvo | -3.172e-04 | 1.751e-04 | 5.14 +/- 0.14 | (7.34+/-7.03)e-4 | V | DPA +5V ANALOG B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jan 16, 2026
Last Site Modification: Sep 30, 2021