| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.011 | 8.576e-04 | (2.12+/-0.02)e2 | -0.02 +/- 0.64 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.011 | 8.398e-04 | (2.13+/-0.02)e2 | 0.30 +/- 0.60 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.008 | 0.002 | (1.54+/-0.04)e2 | 1.57 +/- 1.20 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -1.375 | 0.056 | (5.84+/-1.42)e2 | -29.67 +/- 34.08 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.003 | 0.002 | (2.64+/-0.04)e2 | -1.14 +/- 1.34 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.019 | 0.003 | (2.90+/-0.06)e2 | 0.98 +/- 1.13 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.021 | 0.003 | (2.90+/-0.07)e2 | 1.06 +/- 1.26 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.021 | 0.003 | (2.93+/-0.07)e2 | 0.88 +/- 1.23 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.007 | 0.001 | (2.50+/-0.03)e2 | -1.16 +/- 0.94 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.007 | 0.001 | (2.46+/-0.02)e2 | -1.18 +/- 0.90 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.015 | 0.003 | (3.05+/-0.06)e2 | -4.34 +/- 1.86 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.016 | 0.003 | (2.99+/-0.06)e2 | -4.21 +/- 1.85 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 0.007 | 0.001 | (3.45+/-0.03)e2 | 0.10 +/- 0.11 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.009 | 9.195e-04 | (1.95+/-0.02)e2 | 0.24 +/- 0.56 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.010 | 9.227e-04 | (1.95+/-0.02)e2 | 0.25 +/- 0.55 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Aug 29, 2026
Last Site Modification: Sep 30, 2021