| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.035 | 0.031 | (2.13+/-0.03)e2 | (2.91+/-1.00)e2 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.114 | 0.027 | (2.13+/-0.02)e2 | (1.43+/-1.04)e2 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.250 | 0.062 | (1.54+/-0.05)e2 | (6.80+/-2.08)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -15.660 | 1.618 | (5.96+/-1.39)e2 | -(2.96+/-42.85)e2 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.064 | 0.047 | (2.64+/-0.04)e2 | -(1.82+/-1.38)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.228 | 0.089 | (2.90+/-0.07)e2 | -66.64 +/- 377.22 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.217 | 0.092 | (2.90+/-0.08)e2 | (3.82+/-4.02)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.214 | 0.090 | (2.93+/-0.08)e2 | (6.25+/-3.80)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.062 | 0.032 | (2.51+/-0.03)e2 | -(1.91+/-1.10)e2 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.031 | 0.028 | (2.47+/-0.02)e2 | 71.20 +/- 95.17 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.131 | 0.057 | (3.03+/-0.05)e2 | -(1.26+/-1.91)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.062 | 0.058 | (2.97+/-0.05)e2 | -(1.56+/-1.85)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 3.446e-10 | 1.092e-06 | (3.45+/-0.00)e2 | (2.28+/-104.10)e-9 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.070 | 0.033 | (1.95+/-0.03)e2 | (2.20+/-1.34)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.086 | 0.033 | (1.95+/-0.03)e2 | (2.84+/-1.31)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jun 04, 2026
Last Site Modification: Sep 30, 2021