| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.161 | 0.025 | (2.11+/-0.02)e2 | 95.64 +/- 102.31 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.117 | 0.026 | (2.12+/-0.02)e2 | 43.91 +/- 116.36 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.192 | 0.036 | (1.53+/-0.03)e2 | 48.03 +/- 202.68 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -2.884 | 1.216 | (4.60+/-1.13)e2 | -(5.72+/-5.00)e3 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.190 | 0.047 | (2.63+/-0.04)e2 | (1.35+/-1.59)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.458 | 0.076 | (2.89+/-0.07)e2 | (6.23+/-5.05)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.826 | 0.077 | (2.89+/-0.07)e2 | (7.56+/-5.17)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.756 | 0.075 | (2.92+/-0.07)e2 | (9.33+/-5.02)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.045 | 0.034 | (2.49+/-0.03)e2 | 2.76 +/- 118.42 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.011 | 0.031 | (2.45+/-0.03)e2 | 0.63 +/- 89.33 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -1.108 | 0.073 | (3.07+/-0.07)e2 | (6.42+/-2.62)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -1.112 | 0.071 | (3.01+/-0.07)e2 | (5.71+/-2.48)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | -0.214 | 0.032 | (3.45+/-0.03)e2 | 55.42 +/- 91.44 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.152 | 0.022 | (1.94+/-0.02)e2 | (1.37+/-1.28)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.145 | 0.022 | (1.94+/-0.02)e2 | 62.12 +/- 128.21 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 10, 2026