| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 8.548e-04 | 1.029e-04 | (2.12+/-0.02)e2 | -0.03 +/- 0.04 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 8.093e-04 | 1.024e-04 | (2.13+/-0.02)e2 | -0.02 +/- 0.04 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 8.343e-04 | 1.905e-04 | (1.55+/-0.04)e2 | 0.01 +/- 0.06 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 0.051 | 0.005 | (6.14+/-1.19)e2 | 0.30 +/- 0.93 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 3.833e-04 | 1.802e-04 | (2.64+/-0.04)e2 | -0.10 +/- 0.07 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.003 | 3.023e-04 | (2.91+/-0.07)e2 | -0.02 +/- 0.06 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.003 | 3.111e-04 | (2.91+/-0.07)e2 | 0.05 +/- 0.07 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.003 | 3.050e-04 | (2.94+/-0.07)e2 | 0.04 +/- 0.07 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 5.610e-04 | 1.293e-04 | (2.50+/-0.03)e2 | -0.06 +/- 0.06 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 6.016e-04 | 1.225e-04 | (2.47+/-0.03)e2 | -0.04 +/- 0.05 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.002 | 2.691e-04 | (3.06+/-0.06)e2 | 0.09 +/- 0.09 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.002 | 2.632e-04 | (3.00+/-0.06)e2 | 0.09 +/- 0.09 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 4.666e-04 | 1.439e-04 | (3.45+/-0.03)e2 | -0.03 +/- 0.02 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 7.221e-04 | 1.035e-04 | (1.95+/-0.02)e2 | 0.02 +/- 0.03 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 7.507e-04 | 1.046e-04 | (1.95+/-0.02)e2 | 0.01 +/- 0.03 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 12, 2026
Last Site Modification: Sep 30, 2021