One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
---|
Delta/Yr below is a slope of the liear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
---|---|---|---|---|---|---|---|---|
1cbat | 0.342 | 0.021 | (2.10+/-0.02)e2 | 0.67 +/- 0.94 | K | CAMERA BODY TEMP. A | No Violation Check | |
1cbbt | 0.345 | 0.020 | (2.10+/-0.02)e2 | 0.99 +/- 0.94 | K | CAMERA BODY TEMP. B | No Violation Check | |
1crat | 0.610 | 0.024 | (1.50+/-0.03)e2 | 0.48 +/- 0.98 | K | COLD RADIATOR TEMP. A | No Violation Check | |
1crbt | 0.633 | 0.025 | (1.51+/-0.03)e2 | 0.41 +/- 0.99 | K | COLD RADIATOR TEMP. B | No Violation Check | |
1dactbt | 0.429 | 0.028 | (2.59+/-0.03)e2 | 0.43 +/- 1.21 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
1deamzt | -0.535 | 0.050 | (2.91+/-0.05)e2 | 0.80 +/- 2.10 | K | DEA -Z PANEL TEMP | No Violation Check | |
1dpamyt | -0.644 | 0.052 | (2.91+/-0.05)e2 | 1.30 +/- 2.10 | K | DPA -Y PANEL TEMP | No Violation Check | |
1dpamzt | -0.663 | 0.050 | (2.94+/-0.05)e2 | 0.80 +/- 2.06 | K | DPA -Z PANEL TEMP | No Violation Check | |
1oahat | 0.168 | 0.022 | (2.46+/-0.02)e2 | 0.62 +/- 0.74 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
1oahbt | 0.353 | 0.021 | (2.43+/-0.02)e2 | 0.69 +/- 0.95 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
1pdeaat | -0.551 | 0.054 | (3.04+/-0.06)e2 | -0.83 +/- 2.33 | K | PSMC DEA PS A TEMP | No Violation Check | |
1pdeabt | -0.542 | 0.052 | (2.96+/-0.05)e2 | -1.43 +/- 2.27 | K | PSMC DEA PS B TEMP | No Violation Check | |
1pin1at | 2.259 | 0.074 | (3.40+/-0.09)e2 | -1.61 +/- 2.42 | K | PSMC TEMP 1A | No Violation Check | |
1wrat | 0.309 | 0.019 | (1.93+/-0.02)e2 | 0.84 +/- 0.87 | K | WARM RADIATOR TEMP. A | No Violation Check | |
1wrbt | 0.337 | 0.019 | (1.92+/-0.02)e2 | 0.80 +/- 0.87 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Aug 10, 2023
Last Site Modification: Sep 30, 2021