One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
---|
Delta/Yr below is a slope of the liear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
---|---|---|---|---|---|---|---|---|
1cbat | -0.023 | 0.004 | (2.09+/-0.03)e2 | 0.02 +/- 0.05 | K | CAMERA BODY TEMP. A | No Violation | |
1cbbt | -0.120 | 0.005 | (2.10+/-0.03)e2 | 0.00 +/- 0.05 | K | CAMERA BODY TEMP. B | No Violation | |
1crat | 0.216 | 0.003 | (1.48+/-0.03)e2 | -0.00 +/- 0.05 | K | COLD RADIATOR TEMP. A | No Violation | |
1crbt | 0.233 | 0.004 | (1.48+/-0.03)e2 | -0.01 +/- 0.05 | K | COLD RADIATOR TEMP. B | No Violation | |
1dactbt | 0.118 | 0.003 | (2.58+/-0.02)e2 | 0.07 +/- 0.06 | K | DA COLLIMATOR TEMP. B | No Violation | |
1deamzt | 0.512 | 0.006 | (2.87+/-0.06)e2 | -0.10 +/- 0.12 | K | DEA -Z PANEL TEMP | No Violation | |
1dpamyt | 0.454 | 0.007 | (2.88+/-0.06)e2 | -0.22 +/- 0.14 | K | DPA -Y PANEL TEMP | No Violation | |
1dpamzt | 0.427 | 0.006 | (2.91+/-0.05)e2 | -0.17 +/- 0.13 | K | DPA -Z PANEL TEMP | No Violation | |
1oahat | 0.131 | 0.004 | (2.44+/-0.02)e2 | -0.00 +/- 0.05 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation | |
1oahbt | 0.132 | 0.003 | (2.41+/-0.02)e2 | 0.06 +/- 0.05 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation | |
1pdeaat | -0.028 | 0.009 | (3.04+/-0.06)e2 | -0.24 +/- 0.21 | K | PSMC DEA PS A TEMP | No Violation | |
1pdeabt | 0.049 | 0.009 | (2.96+/-0.06)e2 | -0.22 +/- 0.21 | K | PSMC DEA PS B TEMP | No Violation | |
1pin1at | 2.744 | 0.020 | (3.07+/-0.24)e2 | -0.20 +/- 0.21 | K | PSMC TEMP 1A | No Violation | |
1wrat | 0.098 | 0.003 | (1.91+/-0.02)e2 | -0.01 +/- 0.05 | K | WARM RADIATOR TEMP. A | No Violation | |
1wrbt | 0.087 | 0.003 | (1.91+/-0.02)e2 | -0.01 +/- 0.05 | K | WARM RADIATOR TEMP. B | No Violation |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Aug 10, 2023
Last Site Modification: Sep 30, 2021