| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.001 | 0.001 | (2.13+/-0.02)e2 | -0.28 +/- 0.79 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.001 | 0.001 | (2.13+/-0.02)e2 | -0.58 +/- 0.77 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.002 | 0.002 | (1.54+/-0.04)e2 | -1.22 +/- 1.14 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -0.061 | 0.011 | (6.74+/-0.25)e2 | 2.16 +/- 4.38 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.005 | 0.002 | (2.64+/-0.04)e2 | 1.50 +/- 1.57 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.008 | 0.003 | (2.91+/-0.07)e2 | -1.85 +/- 1.25 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.010 | 0.003 | (2.90+/-0.07)e2 | -2.16 +/- 1.39 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.010 | 0.003 | (2.93+/-0.07)e2 | -2.08 +/- 1.34 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.002 | 0.001 | (2.50+/-0.03)e2 | 0.38 +/- 1.14 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.001 | 0.001 | (2.46+/-0.03)e2 | 0.46 +/- 1.05 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.003 | 0.002 | (3.05+/-0.05)e2 | -2.68 +/- 1.31 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.001 | 0.002 | (2.98+/-0.05)e2 | -1.99 +/- 1.28 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 6.163e-04 | 0.001 | (3.45+/-0.03)e2 | 0.15 +/- 0.36 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.002 | 0.001 | (1.95+/-0.02)e2 | -0.56 +/- 0.71 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.002 | 0.001 | (1.95+/-0.02)e2 | -0.59 +/- 0.71 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Mar 19, 2026
Last Site Modification: Sep 30, 2021