| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 4.415e-04 | 8.571e-04 | (2.12+/-0.02)e2 | 0.13 +/- 0.69 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 2.215e-04 | 8.354e-04 | (2.12+/-0.02)e2 | -0.08 +/- 0.69 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.006 | 0.002 | (1.53+/-0.04)e2 | -0.59 +/- 0.97 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -1.407 | 0.060 | (5.20+/-1.51)e2 | 3.71 +/- 30.66 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -3.917e-04 | 0.002 | (2.62+/-0.04)e2 | 0.36 +/- 1.47 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.003 | 0.003 | (2.89+/-0.06)e2 | 0.75 +/- 1.09 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.003 | 0.003 | (2.88+/-0.06)e2 | 0.45 +/- 1.16 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.003 | 0.003 | (2.91+/-0.06)e2 | 0.59 +/- 1.13 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -3.257e-04 | 0.001 | (2.49+/-0.03)e2 | 0.28 +/- 1.06 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -2.054e-04 | 0.001 | (2.45+/-0.02)e2 | 0.26 +/- 0.98 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.021 | 0.003 | (3.04+/-0.06)e2 | 1.00 +/- 1.80 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.022 | 0.002 | (2.96+/-0.06)e2 | 0.32 +/- 1.75 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 0.002 | 0.001 | (3.45+/-0.03)e2 | -0.08 +/- 0.21 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.001 | 8.761e-04 | (1.94+/-0.02)e2 | 0.12 +/- 0.56 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.001 | 8.795e-04 | (1.94+/-0.02)e2 | 0.02 +/- 0.57 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 03, 2026
Last Site Modification: Sep 30, 2021