Back to Top

ACISTEMP
Static Version: Mean --- One Week

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
1cbat -0.2650.025(2.13+/-0.02)e2(2.02+/-0.91)e2KCAMERA BODY TEMP. ANo Violation Check
1cbbt -0.2790.023(2.13+/-0.02)e2(1.97+/-0.92)e2KCAMERA BODY TEMP. BNo Violation Check
1crat -0.5690.054(1.54+/-0.05)e2(1.45+/-2.33)e2KCOLD RADIATOR TEMP. ANo Violation Check
1crbt 2.5120.568(6.65+/-0.53)e2(5.83+/-18.03)e2KCOLD RADIATOR TEMP. BNo Violation Check
1dactbt 0.2640.041(2.63+/-0.04)e2(2.55+/-1.14)e2KDA COLLIMATOR TEMP. BNo Violation Check
1deamzt -0.1890.073(2.90+/-0.07)e2(8.90+/-4.14)e2KDEA -Z PANEL TEMPNo Violation Check
1dpamyt -0.1310.075(2.90+/-0.07)e2(9.46+/-4.22)e2KDPA -Y PANEL TEMPNo Violation Check
1dpamzt -0.1820.074(2.93+/-0.07)e2(6.65+/-4.13)e2KDPA -Z PANEL TEMPNo Violation Check
1oahat -0.0190.027(2.50+/-0.03)e2(2.74+/-0.78)e2KOPEN ACTUATOR HOUSING TEMP. ANo Violation Check
1oahbt -0.0040.025(2.46+/-0.02)e2(1.52+/-0.67)e2KOPEN ACTUATOR HOUSING TEMP. BNo Violation Check
1pdeaat 0.8520.045(3.03+/-0.05)e2(2.82+/-2.01)e2KPSMC DEA PS A TEMPNo Violation Check
1pdeabt 0.7430.044(2.95+/-0.04)e2(1.84+/-1.97)e2KPSMC DEA PS B TEMPNo Violation Check
1pin1at 6.221e-111.020e-06(3.45+/-0.00)e2(1.03+/-0.19)e-7KPSMC TEMP 1ANo Violation Check
1wrat -0.3130.029(1.95+/-0.03)e2(2.18+/-1.38)e2KWARM RADIATOR TEMP. ANo Violation Check
1wrbt -0.3100.029(1.95+/-0.03)e2(2.25+/-1.35)e2KWARM RADIATOR TEMP. BNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Feb 03, 2026