| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.110 | 0.023 | (2.13+/-0.02)e2 | 0.91 +/- 96.78 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.074 | 0.021 | (2.14+/-0.02)e2 | 20.23 +/- 94.91 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.331 | 0.047 | (1.55+/-0.04)e2 | -(4.79+/-2.16)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 1.099 | 0.250 | (6.75+/-0.23)e2 | 4.75 +/- 5.88 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.115 | 0.038 | (2.63+/-0.04)e2 | (1.35+/-1.10)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.252 | 0.078 | (2.90+/-0.07)e2 | -(1.28+/-4.56)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.098 | 0.069 | (2.92+/-0.06)e2 | -(1.86+/-3.78)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.041 | 0.070 | (2.95+/-0.06)e2 | -(1.71+/-3.90)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.080 | 0.026 | (2.50+/-0.02)e2 | 81.09 +/- 69.42 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.083 | 0.024 | (2.46+/-0.02)e2 | 37.03 +/- 63.38 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.064 | 0.032 | (3.01+/-0.03)e2 | -19.23 +/- 164.13 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.136 | 0.032 | (2.94+/-0.03)e2 | -(2.06+/-1.66)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 1.197e-11 | 1.024e-06 | (3.45+/-0.00)e2 | (1.34+/-0.07)e-7 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.186 | 0.024 | (1.96+/-0.02)e2 | -(1.72+/-1.32)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.192 | 0.024 | (1.96+/-0.02)e2 | -87.41 +/- 130.23 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jan 13, 2026
Last Site Modification: Sep 30, 2021