| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.021 | 0.031 | (2.12+/-0.03)e2 | (3.01+/-0.98)e2 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.130 | 0.027 | (2.13+/-0.02)e2 | (1.71+/-0.97)e2 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.240 | 0.063 | (1.53+/-0.05)e2 | (6.41+/-2.00)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -15.726 | 1.624 | (5.95+/-1.39)e2 | -(2.73+/-4.47)e3 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.023 | 0.046 | (2.64+/-0.04)e2 | -(1.33+/-1.16)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.233 | 0.089 | (2.90+/-0.07)e2 | -26.06 +/- 376.96 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.220 | 0.092 | (2.90+/-0.08)e2 | (3.76+/-4.02)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.218 | 0.090 | (2.93+/-0.08)e2 | (4.85+/-3.80)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.056 | 0.031 | (2.50+/-0.03)e2 | -89.98 +/- 82.41 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.078 | 0.028 | (2.46+/-0.02)e2 | -(1.29+/-0.68)e2 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.131 | 0.057 | (3.03+/-0.05)e2 | -(2.48+/-1.81)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.060 | 0.057 | (2.95+/-0.05)e2 | -(1.45+/-1.73)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 3.446e-10 | 1.092e-06 | (3.45+/-0.00)e2 | (2.28+/-104.10)e-9 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.075 | 0.033 | (1.95+/-0.03)e2 | (2.93+/-1.31)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.097 | 0.033 | (1.95+/-0.03)e2 | (2.69+/-1.33)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jun 04, 2026
Last Site Modification: Sep 30, 2021