Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
1cbat -0.5760.024(2.12+/-0.02)e2-(1.31+/-1.33)e2KCAMERA BODY TEMP. ANo Violation Check
1cbbt -0.5530.023(2.13+/-0.02)e2-49.88 +/- 140.25KCAMERA BODY TEMP. BNo Violation Check
1crat -0.3620.043(1.55+/-0.03)e2-(3.68+/-2.69)e2KCOLD RADIATOR TEMP. ANo Violation Check
1crbt 13.1710.999(4.21+/-0.83)e2(6.03+/-6.50)e3KCOLD RADIATOR TEMP. BNo Violation Check
1dactbt -0.7890.044(2.62+/-0.04)e291.58 +/- 170.79KDA COLLIMATOR TEMP. BNo Violation Check
1deamzt -0.7560.098(2.91+/-0.08)e2-(1.68+/-7.04)e2KDEA -Z PANEL TEMPNo Violation Check
1dpamyt -0.9020.098(2.91+/-0.08)e2-(2.96+/-6.85)e2KDPA -Y PANEL TEMPNo Violation Check
1dpamzt -0.8510.096(2.94+/-0.08)e2-(2.37+/-6.76)e2KDPA -Z PANEL TEMPNo Violation Check
1oahat -0.6990.030(2.49+/-0.03)e2-93.58 +/- 101.57KOPEN ACTUATOR HOUSING TEMP. ANo Violation Check
1oahbt -0.6480.025(2.45+/-0.02)e2-49.69 +/- 79.42KOPEN ACTUATOR HOUSING TEMP. BNo Violation Check
1pdeaat -0.2580.061(3.04+/-0.05)e2-(3.06+/-3.06)e2KPSMC DEA PS A TEMPNo Violation Check
1pdeabt -0.2380.060(2.97+/-0.05)e2-58.44 +/- 296.51KPSMC DEA PS B TEMPNo Violation Check
1pin1at 0.0730.015(3.45+/-0.01)e2-(1.81+/-2.35)e-7KPSMC TEMP 1ANo Violation Check
1wrat -0.4670.024(1.95+/-0.02)e2-(1.31+/-1.71)e2KWARM RADIATOR TEMP. ANo Violation Check
1wrbt -0.4840.024(1.95+/-0.02)e2-(1.51+/-1.71)e2KWARM RADIATOR TEMP. BNo Violation Check