| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.488 | 0.020 | (2.12+/-0.02)e2 | 7.73 +/- 70.42 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.499 | 0.021 | (2.13+/-0.02)e2 | -2.62 +/- 98.57 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.416 | 0.049 | (1.53+/-0.05)e2 | -78.10 +/- 193.78 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 15.499 | 0.938 | (6.42+/-0.93)e2 | -(6.05+/-2.82)e3 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.371 | 0.038 | (2.62+/-0.04)e2 | (1.62+/-0.96)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.780 | 0.067 | (2.89+/-0.06)e2 | -(3.00+/-3.46)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.810 | 0.068 | (2.90+/-0.07)e2 | -(2.48+/-3.42)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.823 | 0.067 | (2.93+/-0.06)e2 | -(2.47+/-3.27)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.499 | 0.025 | (2.49+/-0.03)e2 | -19.12 +/- 59.98 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.450 | 0.023 | (2.46+/-0.02)e2 | 59.94 +/- 57.66 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.448 | 0.062 | (3.01+/-0.06)e2 | (4.74+/-2.18)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.420 | 0.060 | (2.93+/-0.06)e2 | (3.53+/-2.09)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | -0.107 | 0.029 | (3.45+/-0.03)e2 | (1.45+/-0.83)e-7 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.385 | 0.024 | (1.95+/-0.02)e2 | (1.09+/-1.15)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.395 | 0.024 | (1.95+/-0.02)e2 | 17.80 +/- 115.92 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: May 09, 2026
Last Site Modification: Sep 30, 2021