| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.624 | 0.021 | (2.09+/-0.03)e2 | -0.39 +/- 1.00 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.642 | 0.021 | (2.10+/-0.03)e2 | -0.26 +/- 0.98 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.485 | 0.026 | (1.48+/-0.03)e2 | 0.61 +/- 1.06 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 107.349 | 1.358 | (3.52+/-2.50)e2 | 10.49 +/- 23.71 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.567 | 0.036 | (2.57+/-0.04)e2 | -0.35 +/- 1.39 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.017 | 0.048 | (2.83+/-0.05)e2 | 0.80 +/- 1.67 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.006 | 0.051 | (2.83+/-0.06)e2 | 1.16 +/- 1.86 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.005 | 0.047 | (2.86+/-0.05)e2 | 0.24 +/- 1.69 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.207 | 0.027 | (2.44+/-0.02)e2 | 0.92 +/- 0.86 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.610 | 0.024 | (2.42+/-0.03)e2 | -0.15 +/- 1.09 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.033 | 0.050 | (2.97+/-0.06)e2 | -0.30 +/- 2.04 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.175 | 0.048 | (2.88+/-0.05)e2 | 0.76 +/- 1.99 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 2.158 | 0.106 | (3.39+/-0.12)e2 | 0.01 +/- 3.77 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.536 | 0.020 | (1.92+/-0.02)e2 | -0.09 +/- 0.89 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.566 | 0.020 | (1.91+/-0.02)e2 | -0.15 +/- 0.90 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jun 23, 2026