| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.668 | 0.024 | (2.09+/-0.03)e2 | -0.00 +/- 1.00 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.685 | 0.023 | (2.10+/-0.03)e2 | 0.06 +/- 0.99 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.532 | 0.028 | (1.48+/-0.03)e2 | 1.15 +/- 1.03 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 114.938 | 1.474 | (3.36+/-2.49)e2 | 42.21 +/- 19.07 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.521 | 0.039 | (2.57+/-0.04)e2 | 0.13 +/- 1.39 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.017 | 0.053 | (2.83+/-0.05)e2 | 0.21 +/- 1.70 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.056 | 0.057 | (2.83+/-0.06)e2 | 1.27 +/- 1.89 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.032 | 0.053 | (2.86+/-0.05)e2 | 0.57 +/- 1.72 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.207 | 0.027 | (2.44+/-0.02)e2 | 0.92 +/- 0.86 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.617 | 0.027 | (2.42+/-0.03)e2 | 0.02 +/- 1.07 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.183 | 0.055 | (2.97+/-0.05)e2 | -0.53 +/- 2.03 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.338 | 0.053 | (2.88+/-0.05)e2 | 0.31 +/- 1.99 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 2.498 | 0.118 | (3.39+/-0.12)e2 | -0.95 +/- 4.02 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.588 | 0.022 | (1.92+/-0.02)e2 | -0.17 +/- 0.90 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.618 | 0.022 | (1.91+/-0.02)e2 | 0.46 +/- 0.90 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jan 19, 2026
Last Site Modification: Sep 30, 2021