| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.642 | 0.022 | (2.09+/-0.03)e2 | -1.06 +/- 1.01 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.663 | 0.022 | (2.10+/-0.03)e2 | -0.78 +/- 0.99 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.508 | 0.027 | (1.48+/-0.03)e2 | 0.32 +/- 1.05 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 112.861 | 1.381 | (3.47+/-2.51)e2 | 43.27 +/- 21.21 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.561 | 0.038 | (2.57+/-0.04)e2 | 0.10 +/- 1.42 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.019 | 0.050 | (2.83+/-0.05)e2 | 0.97 +/- 1.69 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.011 | 0.054 | (2.83+/-0.06)e2 | 1.53 +/- 1.89 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.003 | 0.049 | (2.86+/-0.05)e2 | 0.69 +/- 1.71 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.207 | 0.027 | (2.44+/-0.02)e2 | 0.92 +/- 0.86 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.616 | 0.026 | (2.42+/-0.03)e2 | -0.43 +/- 1.10 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.030 | 0.053 | (2.97+/-0.06)e2 | 3.22 +/- 2.04 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.176 | 0.051 | (2.88+/-0.05)e2 | 4.36 +/- 1.98 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 2.270 | 0.111 | (3.39+/-0.12)e2 | -4.92 +/- 3.89 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.555 | 0.021 | (1.92+/-0.02)e2 | -0.43 +/- 0.90 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.587 | 0.021 | (1.91+/-0.02)e2 | -0.67 +/- 0.91 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Apr 16, 2026
Last Site Modification: Sep 30, 2021