| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.659 | 0.020 | (2.09+/-0.03)e2 | -0.44 +/- 1.01 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.664 | 0.019 | (2.10+/-0.03)e2 | -0.07 +/- 1.00 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.541 | 0.023 | (1.48+/-0.03)e2 | 1.19 +/- 1.02 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 96.139 | 1.275 | (3.12+/-2.41)e2 | 51.73 +/- 19.50 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.530 | 0.033 | (2.57+/-0.04)e2 | 0.19 +/- 1.39 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.142 | 0.044 | (2.83+/-0.05)e2 | 1.76 +/- 1.70 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.190 | 0.048 | (2.83+/-0.06)e2 | 1.40 +/- 1.87 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.161 | 0.044 | (2.86+/-0.05)e2 | 1.57 +/- 1.70 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.207 | 0.027 | (2.44+/-0.02)e2 | 0.92 +/- 0.86 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.589 | 0.022 | (2.42+/-0.03)e2 | -(4.24+/-10780.00)e-4 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.108 | 0.047 | (2.97+/-0.05)e2 | 1.98 +/- 2.02 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.279 | 0.045 | (2.88+/-0.05)e2 | 3.26 +/- 1.97 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 2.894 | 0.108 | (3.38+/-0.14)e2 | -6.04 +/- 4.10 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.583 | 0.019 | (1.91+/-0.02)e2 | -0.06 +/- 0.91 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.613 | 0.019 | (1.91+/-0.02)e2 | 0.09 +/- 0.91 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Dec 29, 2025
Last Site Modification: Sep 30, 2021