| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.002 | 8.734e-04 | (2.11+/-0.02)e2 | -0.10 +/- 0.73 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 8.781e-04 | 8.671e-04 | (2.12+/-0.02)e2 | -0.11 +/- 0.73 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.007 | 0.002 | (1.52+/-0.04)e2 | -0.93 +/- 0.85 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -1.309 | 0.062 | (4.88+/-1.54)e2 | 17.89 +/- 26.92 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.002 | 0.002 | (2.62+/-0.04)e2 | 0.16 +/- 1.57 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.004 | 0.003 | (2.87+/-0.06)e2 | 0.54 +/- 1.11 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.002 | 0.003 | (2.87+/-0.06)e2 | 0.60 +/- 1.16 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.003 | 0.003 | (2.90+/-0.06)e2 | 0.46 +/- 1.12 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.001 | 0.001 | (2.49+/-0.03)e2 | 0.08 +/- 1.14 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 5.438e-04 | 0.001 | (2.44+/-0.02)e2 | 0.16 +/- 1.07 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.032 | 0.003 | (3.03+/-0.06)e2 | 1.38 +/- 1.84 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.033 | 0.003 | (2.93+/-0.06)e2 | 0.61 +/- 1.77 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | -0.007 | 0.002 | (3.44+/-0.05)e2 | 0.05 +/- 0.69 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.002 | 8.838e-04 | (1.94+/-0.02)e2 | -0.10 +/- 0.59 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.002 | 8.886e-04 | (1.94+/-0.02)e2 | -0.04 +/- 0.59 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 10, 2026
Last Site Modification: Sep 30, 2021