| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.328 | 0.020 | (2.12+/-0.02)e2 | -(1.71+/-1.01)e2 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.390 | 0.021 | (2.12+/-0.02)e2 | -86.56 +/- 100.75 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.813 | 0.053 | (1.52+/-0.05)e2 | -(4.55+/-2.27)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 0.147 | 0.303 | (6.73+/-0.29)e2 | -17.44 +/- 197.95 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.105 | 0.035 | (2.63+/-0.03)e2 | -(1.12+/-1.32)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.386 | 0.076 | (2.90+/-0.07)e2 | -(9.11+/-4.42)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.574 | 0.089 | (2.88+/-0.08)e2 | -(3.75+/-4.86)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.523 | 0.085 | (2.92+/-0.08)e2 | -(5.51+/-4.73)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.178 | 0.023 | (2.50+/-0.02)e2 | -(2.25+/-0.83)e2 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.114 | 0.021 | (2.45+/-0.02)e2 | -(1.50+/-0.69)e2 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.228 | 0.039 | (3.05+/-0.04)e2 | 81.03 +/- 169.40 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.296 | 0.041 | (2.96+/-0.04)e2 | -(1.09+/-1.64)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | -0.052 | 0.016 | (3.45+/-0.01)e2 | (6.62+/-3.56)e-8 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.462 | 0.028 | (1.94+/-0.03)e2 | -(1.42+/-1.39)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.433 | 0.028 | (1.94+/-0.03)e2 | -(1.71+/-1.46)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Feb 25, 2026
Last Site Modification: Sep 30, 2021