| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -6.152e-04 | 9.070e-05 | (2.12+/-0.02)e2 | -0.04 +/- 0.03 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -6.099e-04 | 9.008e-05 | (2.13+/-0.02)e2 | -0.05 +/- 0.03 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -9.922e-05 | 1.570e-04 | (1.52+/-0.04)e2 | -0.00 +/- 0.04 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 0.037 | 0.002 | (6.64+/-0.58)e2 | 0.24 +/- 0.40 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.001 | 1.620e-04 | (2.62+/-0.04)e2 | -0.07 +/- 0.07 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 3.747e-04 | 2.562e-04 | (2.88+/-0.07)e2 | -0.08 +/- 0.06 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 5.671e-04 | 2.633e-04 | (2.88+/-0.07)e2 | -0.05 +/- 0.06 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 6.056e-04 | 2.555e-04 | (2.91+/-0.07)e2 | -0.06 +/- 0.06 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.001 | 1.154e-04 | (2.49+/-0.03)e2 | -0.05 +/- 0.05 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.001 | 1.072e-04 | (2.45+/-0.03)e2 | -0.03 +/- 0.04 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.001 | 2.279e-04 | (3.02+/-0.06)e2 | -0.14 +/- 0.07 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -9.294e-04 | 2.218e-04 | (2.93+/-0.06)e2 | -0.13 +/- 0.07 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 0.001 | 1.605e-04 | (3.44+/-0.04)e2 | -0.01 +/- 0.02 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -3.986e-04 | 8.946e-05 | (1.94+/-0.02)e2 | -0.03 +/- 0.03 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -3.998e-04 | 9.072e-05 | (1.94+/-0.02)e2 | -0.04 +/- 0.03 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jun 08, 2026
Last Site Modification: Sep 30, 2021