Back to Top

EPSBATT
Static Version: Max --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
eb1cioff0.0080.0050.42 +/- 0.510.10 +/- 0.13AMPBATT 1 CHARGE CURRENTNo Violation Check
on-0.0310.0961.64 +/- 0.96(0.00+/-0.00)e0No Violation Check
eb1dioff0.0340.0280.81 +/- 3.130.80 +/- 0.75AMPBATT 1 DISCHARGE CURRENTNo Violation Check
on-0.4360.5868.00 +/- 5.93(0.00+/-0.00)e0No Violation Check
eb1voff-9.514e-040.00232.40 +/- 0.170.01 +/- 0.04VBATT 1 VOLTAGENo Violation Check
on0.0630.06032.18 +/- 0.61(0.00+/-0.00)e0No Violation Check
eb2cioff-0.0040.0040.43 +/- 0.480.09 +/- 0.12AMPBATT 2 CHARGE CURRENTNo Violation Check
on-0.0170.0931.55 +/- 0.91(0.00+/-0.00)e0No Violation Check
eb2dioff0.0330.0290.83 +/- 3.301.02 +/- 0.80AMPBATT 2 DISCHARGE CURRENTNo Violation Check
on-0.1880.6308.06 +/- 6.15(0.00+/-0.00)e0No Violation Check
eb2voff-0.0120.00132.39 +/- 0.170.07 +/- 0.04VBATT 2 VOLTAGENo Violation Check
on0.0640.06032.19 +/- 0.59(0.00+/-0.00)e0No Violation Check
eb3cioff-0.0140.0030.39 +/- 0.340.04 +/- 0.09AMPBATT 3 CHARGE CURRENTNo Violation Check
on-0.0470.0621.21 +/- 0.65(0.00+/-0.00)e0No Violation Check
eb3dioff0.0410.0300.85 +/- 3.371.03 +/- 0.82AMPBATT 3 DISCHARGE CURRENTNo Violation Check
on-0.4980.6218.73 +/- 6.52(0.00+/-0.00)e0No Violation Check
eb3voff-0.0320.00132.12 +/- 0.15-0.02 +/- 0.03VBATT 3 VOLTAGENo Violation Check
on0.0130.05831.92 +/- 0.60(0.00+/-0.00)e0No Violation Check
ecnv1v 8.876e-044.818e-0415.04 +/- 0.060.01 +/- 0.01VCONV 1 +15V OUTPUTNo Violation Check
ecnv2v 9.551e-045.591e-0414.98 +/- 0.060.01 +/- 0.02VCONV 2 +15V OUTPUTNo Violation Check
ecnv3v 1.532e-041.586e-0415.39 +/- 0.02(8.80+/-453.40)e-5VCONV 3 +15V OUTPUTNo Violation Check
eepa5v 0.0010.0025.27 +/- 0.18-0.00 +/- 0.00V+5V RCTU_EP ANo Violation Check
eepb5v -0.0020.0020.07 +/- 0.23-0.01 +/- 0.01V+5V RCTU_EP BNo Violation Check
eochrgb1 7.749e-063.744e-051.00 +/- 0.00(0.00+/-0.00)e0naBATT 1 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 )No Violation Check
eochrgb2 9.502e-063.718e-051.00 +/- 0.00(0.00+/-0.00)e0naBATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 )No Violation Check
eochrgb3 6.861e-063.782e-051.00 +/- 0.00(0.00+/-0.00)e0naBATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 )No Violation Check
eoesac1c -0.1870.01212.80 +/- 1.40-0.15 +/- 0.41na-Y SOLAR ARRAY CURRENT - COUNTS (ESAMYI)No Violation Check
eoesac2c -0.2050.01112.41 +/- 1.34-0.02 +/- 0.38na+Y SOLAR ARRAY CURRENT - COUNTS (ESAPYI)No Violation Check
eoeb1dic 0.0040.0070.09 +/- 0.810.07 +/- 0.15AMPTTERY 1 DISCHARGE CURRENT - COUNTS (EB1DI)No Violation Check
eoeb1vc -0.0050.00132.52 +/- 0.160.04 +/- 0.03naBATTERY 1 VOLTAGE - COUNTSNo Violation Check
eoeb2cic -0.0090.0020.33 +/- 0.24-0.01 +/- 0.06naBATTERY 2 CHARGE CURRENT - COUNTS ( EB2CI)No Violation Check
eoeb2vc -0.0150.00132.32 +/- 0.15-0.01 +/- 0.03naVOLTAGE - COUNTSNo Violation Check
eoeb3cic -0.0190.0020.32 +/- 0.19-0.03 +/- 0.05naBATTERY 3 CHARGE CURRENT - COUNTS ( EB3CI)No Violation Check
eoeb3vc -0.0320.00132.25 +/- 0.15-0.03 +/- 0.03naBATTERY 3 VOLTAGE - COUNTSNo Violation Check
eoecnv1c -0.0043.904e-0415.00 +/- 0.040.02 +/- 0.01naPCU CONVERTER 1: +15V OUTPUT - ANALOG (ECNV1V)No Violation Check
eoecnv2c -0.0012.903e-0414.95 +/- 0.03-0.00 +/- 0.01naPCU CONVERTER 2: +15V OUTPUT - ANALOG (ECNV2V)No Violation Check
eoecnv3c -0.0022.349e-0415.38 +/- 0.030.00 +/- 0.01naPCU CONVERTER 3: +15V OUTPUT - ANALOG (ECNV3V)No Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Aug 20, 2026
Last Site Modification: Sep 30, 2021