| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| eb1ci | off | 7.195e-06 | 3.445e-06 | 0.31 +/- 0.09 | -(2.96+/-1.53)e-4 | AMP | BATT 1 CHARGE CURRENT | No Violation Check | on | 2.255e-04 | 1.907e-04 | 0.36 +/- 0.35 | (0.00+/-0.00)e0 | No Violation Check |
| eb1di | off | 5.927e-09 | 8.122e-09 | 0.01 +/- 0.00 | (3.18+/-0.05)e-15 | AMP | BATT 1 DISCHARGE CURRENT | No Violation Check | on | -3.866e-05 | 4.042e-05 | 0.02 +/- 0.07 | (0.00+/-0.00)e0 | No Violation Check |
| eb1v | off | 3.280e-05 | 1.015e-05 | 32.28 +/- 0.27 | -(1.36+/-10.59)e-4 | V | BATT 1 VOLTAGE | No Violation Check | on | -6.344e-04 | 4.998e-04 | 31.87 +/- 0.93 | (0.00+/-0.00)e0 | No Violation Check |
| eb2ci | off | 1.053e-05 | 3.295e-06 | 0.26 +/- 0.09 | -(1.98+/-1.44)e-4 | AMP | BATT 2 CHARGE CURRENT | No Violation Check | on | 2.474e-04 | 1.818e-04 | 0.31 +/- 0.34 | (0.00+/-0.00)e0 | No Violation Check |
| eb2di | off | 5.850e-09 | 8.122e-09 | 0.01 +/- 0.00 | (3.18+/-0.05)e-15 | AMP | BATT 2 DISCHARGE CURRENT | No Violation Check | on | -1.487e-06 | 1.555e-06 | 0.01 +/- 0.00 | (0.00+/-0.00)e0 | No Violation Check |
| eb2v | off | 1.150e-04 | 9.730e-06 | 32.21 +/- 0.26 | (4.25+/-10.30)e-4 | V | BATT 2 VOLTAGE | No Violation Check | on | -6.351e-04 | 4.813e-04 | 31.87 +/- 0.89 | (0.00+/-0.00)e0 | No Violation Check |
| eb3ci | off | 6.540e-06 | 2.938e-06 | 0.25 +/- 0.08 | -(1.20+/-1.42)e-4 | AMP | BATT 3 CHARGE CURRENT | No Violation Check | on | 1.485e-04 | 1.313e-04 | 0.29 +/- 0.24 | (0.00+/-0.00)e0 | No Violation Check |
| eb3di | off | 5.927e-09 | 8.122e-09 | 0.01 +/- 0.00 | (3.18+/-0.05)e-15 | AMP | BATT 3 DISCHARGE CURRENT | No Violation Check | on | -5.725e-05 | 5.986e-05 | 0.03 +/- 0.11 | (0.00+/-0.00)e0 | No Violation Check |
| eb3v | off | 2.604e-05 | 9.585e-06 | 31.89 +/- 0.25 | -(5.02+/-10.13)e-4 | V | BATT 3 VOLTAGE | No Violation Check | on | -8.140e-04 | 4.676e-04 | 31.55 +/- 0.88 | (0.00+/-0.00)e0 | No Violation Check |
| ecnv1v | -1.301e-05 | 1.337e-06 | 14.76 +/- 0.04 | -(1.81+/-2.12)e-4 | V | CONV 1 +15V OUTPUT | No Violation Check | |
| ecnv2v | 1.263e-07 | 2.193e-07 | 14.74 +/- 0.01 | (2.38+/-12.97)e-6 | V | CONV 2 +15V OUTPUT | No Violation Check | |
| ecnv3v | 7.287e-08 | 6.320e-08 | 15.18 +/- 0.00 | -(1.07+/-0.01)e-11 | V | CONV 3 +15V OUTPUT | No Violation Check | |
| eepa5v | -2.145e-16 | 999.000 | 5.24 +/- 0.00 | (2.29+/-0.05)e-12 | V | +5V RCTU_EP A | No Violation Check | |
| eepb5v | -2.731e-18 | 999.000 | 0.04 +/- 0.00 | (1.28+/-0.02)e-14 | V | +5V RCTU_EP B | No Violation Check | |
| eochrgb1 | 1.997e-07 | 3.442e-07 | 1.00 +/- 0.01 | -(6.73+/-35.29)e-6 | na | BATT 1 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eochrgb2 | 1.528e-07 | 3.325e-07 | 1.00 +/- 0.01 | -(3.19+/-3376.00)e-8 | na | BATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eochrgb3 | 1.263e-07 | 3.451e-07 | 1.00 +/- 0.01 | -(9.34+/-367.20)e-7 | na | BATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eoesac1c | 8.044e-05 | 1.105e-04 | 10.34 +/- 1.09 | -0.00 +/- 0.00 | na | -Y SOLAR ARRAY CURRENT - COUNTS (ESAMYI) | No Violation Check | |
| eoesac2c | 7.473e-05 | 1.063e-04 | 10.02 +/- 1.05 | -0.00 +/- 0.00 | na | +Y SOLAR ARRAY CURRENT - COUNTS (ESAPYI) | No Violation Check | |
| eoeb1dic | -7.264e-05 | 3.360e-05 | 0.03 +/- 0.33 | (1.56+/-1.77)e-4 | AMP | TTERY 1 DISCHARGE CURRENT - COUNTS (EB1DI) | No Violation Check | |
| eoeb1vc | 1.539e-04 | 1.838e-04 | 32.03 +/- 1.81 | (4.30+/-28.52)e-4 | na | BATTERY 1 VOLTAGE - COUNTS | No Violation Check | |
| eoeb2cic | 1.340e-05 | 8.502e-06 | 0.26 +/- 0.08 | -(1.35+/-0.71)e-4 | na | BATTERY 2 CHARGE CURRENT - COUNTS ( EB2CI) | No Violation Check | |
| eoeb2vc | 1.765e-04 | 1.839e-04 | 32.05 +/- 1.81 | 0.00 +/- 0.00 | na | VOLTAGE - COUNTS | No Violation Check | |
| eoeb3cic | 1.403e-05 | 7.698e-06 | 0.25 +/- 0.08 | -(1.52+/-0.84)e-4 | na | BATTERY 3 CHARGE CURRENT - COUNTS ( EB3CI) | No Violation Check | |
| eoeb3vc | 1.288e-04 | 1.835e-04 | 32.00 +/- 1.81 | 0.00 +/- 0.00 | na | BATTERY 3 VOLTAGE - COUNTS | No Violation Check | |
| eoecnv1c | 2.228e-06 | 3.783e-06 | 14.83 +/- 0.04 | -(7.74+/-6.99)e-5 | na | PCU CONVERTER 1: +15V OUTPUT - ANALOG (ECNV1V) | No Violation Check | |
| eoecnv2c | -4.190e-06 | 3.828e-06 | 14.77 +/- 0.04 | -(5.32+/-6.59)e-5 | na | PCU CONVERTER 2: +15V OUTPUT - ANALOG (ECNV2V) | No Violation Check | |
| eoecnv3c | 9.886e-07 | 2.822e-06 | 15.19 +/- 0.03 | -(4.50+/-4.82)e-5 | na | PCU CONVERTER 3: +15V OUTPUT - ANALOG (ECNV3V) | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jun 19, 2026
Last Site Modification: Sep 30, 2021