Back to Top

HRCHK
Static Version: Mean --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2c05palvon3.005e-052.568e-054.92 +/- 0.00-(3.35+/-84.34)e-5V+5V bus monitorNo Violation Check
off-1.597e-051.131e-054.92 +/- 0.00(1.32+/-0.37)e-9No Violation Check
2c15nalvon0.1050.001-14.91 +/- 0.08(3.29+/-12.61)e-4V-15V bus monitorNo Violation Check
off-0.0394.977e-04-14.94 +/- 0.08(1.44+/-0.13)e-8No Violation Check
2c15palvon2.920e-054.443e-0514.84 +/- 0.00(3.29+/-12.61)e-4V+15V bus monitorNo Violation Check
off-6.959e-11999.00014.84 +/- 0.00-(8.03+/-1.05)e-9No Violation Check
2c24palvon1.365e-056.537e-0523.91 +/- 0.000.00 +/- 0.00V+24V bus monitorNo Violation Check
off-5.9600.0728.73 +/- 11.610.12 +/- 0.09No Violation Check
2fe00atm -5.5950.06714.24 +/- 11.270.64 +/- 1.04CFront end temperatureNo Violation Check
2fepratmon0.0380.10024.49 +/- 2.0131.21 +/- 18.25CFE temp card temperatureNo Violation Check
off-6.1960.0938.67 +/- 12.46-0.13 +/- 1.30No Violation Check
2imhvatmon-0.6580.08531.62 +/- 1.929.41 +/- 17.54CImaging det HVPS temperatureNo Violation Check
off-3.7680.05822.08 +/- 7.61-0.19 +/- 0.86No Violation Check
2iminatmon0.4650.09619.63 +/- 1.9422.58 +/- 17.64CImaging det temperatureNo Violation Check
off-4.5280.0678.57 +/- 9.07-1.58 +/- 0.76No Violation Check
2lvplatmon-0.7980.08627.87 +/- 1.987.93 +/- 15.82CLVPS plate temperatureNo Violation Check
off-4.3020.06217.08 +/- 8.57-0.23 +/- 0.78No Violation Check
2prbscron0.1170.0031.66 +/- 0.10-0.10 +/- 0.69AMPPrimary bus currentNo Violation Check
off-0.0068.056e-041.73 +/- 0.05-0.01 +/- 0.02No Violation Check
2prbsvl -0.2790.00426.89 +/- 0.590.03 +/- 0.05VPrimary bus voltageNo Violation Check
2smtratmon0.1110.0035.84 +/- 0.12-(9.39+/-8.65)e-9CSelected motor temperatureNo Violation Check
off-0.0698.708e-045.76 +/- 0.14-(4.58+/-0.54)e-9No Violation Check
2sphvatmon-0.7470.09531.86 +/- 2.17-18.34 +/- 19.31CSpect det HVPS temperatureNo Violation Check
off-3.8200.05922.32 +/- 7.710.25 +/- 1.04No Violation Check
2spinatmon-1.2060.09519.50 +/- 2.1016.36 +/- 17.70CSpect det temperatureNo Violation Check
off-3.7120.0569.48 +/- 7.46-1.24 +/- 0.70No Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Feb 05, 2026
Last Site Modification: Sep 30, 2021