Back to Top

HRCTEMP
Static Version: Max --- Last Three Months

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -0.0036.038e-04(2.79+/-0.01)e2-0.61 +/- 0.38KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt -0.0046.210e-04(2.76+/-0.01)e2-0.83 +/- 0.39KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -0.0068.851e-04(2.72+/-0.02)e2-1.26 +/- 0.48KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -0.0035.042e-04(2.74+/-0.01)e2-0.77 +/- 0.29KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt 0.0016.449e-04(2.71+/-0.02)e2-1.13 +/- 0.38KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -0.0080.001(2.67+/-0.02)e2-0.99 +/- 0.67KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -0.0080.001(2.65+/-0.03)e2-0.90 +/- 0.71KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -0.0049.519e-04(2.85+/-0.02)e2-0.95 +/- 0.53KPMT 1 TEMPERATURENo Violation Check
2pmt2t -0.0049.408e-04(2.85+/-0.02)e2-0.91 +/- 0.52KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -0.0076.876e-04(2.76+/-0.02)e2-0.55 +/- 0.42KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: May 25, 2026
Last Site Modification: Sep 30, 2021