Back to Top

HRCTEMP
Static Version: Mean --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -4.3780.061(2.86+/-0.10)e20.55 +/- 0.78KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 0.3220.027(2.96+/-0.03)e20.34 +/- 0.98KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -4.5630.067(2.79+/-0.11)e2-0.33 +/- 0.89KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -3.8810.053(2.80+/-0.09)e20.28 +/- 0.61KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -4.8120.065(2.78+/-0.11)e2-0.03 +/- 0.70KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -6.0050.088(2.76+/-0.14)e2-0.68 +/- 1.16KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -5.5030.082(2.73+/-0.13)e2-0.96 +/- 1.20KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -2.1480.036(2.88+/-0.05)e20.97 +/- 0.94KPMT 1 TEMPERATURENo Violation Check
2pmt2t -2.6070.042(2.89+/-0.06)e21.02 +/- 0.97KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -2.6310.041(2.80+/-0.06)e20.47 +/- 0.75KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Apr 11, 2026
Last Site Modification: Sep 30, 2021