Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -0.0180.018(2.79+/-0.02)e2-36.76 +/- 43.68KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt -0.0230.018(2.76+/-0.02)e25.22 +/- 47.92KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -0.1680.024(2.72+/-0.02)e231.11 +/- 104.22KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -0.1390.012(2.75+/-0.01)e2-28.86 +/- 26.39KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -0.1980.017(2.71+/-0.02)e20.75 +/- 49.62KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -0.3370.027(2.68+/-0.02)e2-(1.53+/-0.60)e2KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -0.3940.028(2.66+/-0.03)e2-(1.83+/-0.81)e2KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -0.2670.023(2.85+/-0.02)e256.88 +/- 90.06KPMT 1 TEMPERATURENo Violation Check
2pmt2t -0.2450.023(2.85+/-0.02)e295.99 +/- 85.05KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -0.2020.012(2.77+/-0.01)e214.54 +/- 30.62KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check