| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| agrndadc | -5.793e-07 | 4.091e-08 | -(3.53+/-1.20)e-4 | -(2.43+/-2.42)e-5 | V | Analog fround A/D convert reading | No Violation Check | |
| fatabadc | -4.173e-06 | 1.644e-07 | 4.99 +/- 0.00 | -(1.72+/-0.93)e-4 | V | FA Tab Position Sensor A/D Converter | No Violation Check | |
| n15vadc | -1.739e-07 | 2.276e-07 | -15.02 +/- 0.00 | -(1.19+/-1.22)e-4 | V | -15V Power Supply A/D Converter Reading | No Violation Check | |
| p15vadc | -1.038e-06 | 7.844e-08 | 14.96 +/- 0.00 | (2.70+/-3.46)e-5 | V | +15V Power Supply A/D Converter Reading | No Violation Check | |
| p5vadc | -4.466e-05 | 9.571e-07 | 4.94 +/- 0.00 | (9.17+/-5.97)e-4 | V | +5V Power Supply A/D Converter Reading | No Violation Check | |
| tsctabadc | 1.127e-05 | 2.423e-05 | 4.99 +/- 0.07 | -(2.97+/-1.19)e-4 | V | TSC Tab Position Sensor A/D converter | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jan 10, 2026
Last Site Modification: Sep 30, 2021