Back to Top

SIMELEC
Static Version: Max --- One Week

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
agrndadc 4.427e-063.511e-06-(5.37+/-2.38)e-4-0.00 +/- 0.01VAnalog fround A/D convert readingNo Violation Check
fatabadc 0.0040.0024.99 +/- 0.170.02 +/- 0.02VFA Tab Position Sensor A/D ConverterNo Violation Check
n15vadc 3.265e-069.458e-06-15.02 +/- 0.00-0.02 +/- 0.03V-15V Power Supply A/D Converter ReadingNo Violation Check
p15vadc 2.169e-066.202e-0614.96 +/- 0.00-0.01 +/- 0.02V+15V Power Supply A/D Converter ReadingNo Violation Check
p5vadc 2.151e-053.626e-054.94 +/- 0.00-0.01 +/- 0.11V+5V Power Supply A/D Converter ReadingNo Violation Check
tsctabadc -0.0050.0034.98 +/- 0.230.63 +/- 0.53VTSC Tab Position Sensor A/D converterNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: May 23, 2026
Last Site Modification: Sep 30, 2021