| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| agrndadc | -9.519e-05 | 4.394e-07 | (4.21+/-8.27)e-4 | (9.27+/-3.65)e-6 | V | Analog fround A/D convert reading | No Violation | |
| fatabadc | -8.097e-05 | 1.909e-05 | 4.99 +/- 0.01 | -(5.75+/-4.46)e-4 | V | FA Tab Position Sensor A/D Converter | No Violation | |
| n15vadc | -4.412e-04 | 1.768e-05 | -15.01 +/- 0.01 | -(7.17+/-90.99)e-7 | V | -15V Power Supply A/D Converter Reading | No Violation | |
| p15vadc | -4.953e-05 | 1.693e-05 | 14.96 +/- 0.01 | (2.59+/-1.74)e-5 | V | +15V Power Supply A/D Converter Reading | Yellow Lower Violation: 2026.8 | |
| p5vadc | 2.520e-04 | 2.765e-05 | 4.96 +/- 0.02 | (1.51+/-35.84)e-5 | V | +5V Power Supply A/D Converter Reading | No Violation | |
| tsctabadc | -3.324e-04 | 3.981e-05 | 4.97 +/- 0.03 | (7.76+/-9.97)e-4 | V | TSC Tab Position Sensor A/D converter | No Violation |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Dec 20, 2025
Last Site Modification: Sep 30, 2021