Back to Top

SIMELEC
Static Version: Mean --- Last Three Months

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the liear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
agrndadc -3.242e-065.164e-07-(3.83+/-0.93)e-4(3.81+/-1.50)e-4VAnalog fround A/D convert readingNo Violation Check
fatabadc -2.463e-052.878e-054.99 +/- 0.080.01 +/- 0.00VFA Tab Position Sensor A/D ConverterNo Violation Check
n15vadc 4.888e-071.280e-07-15.02 +/- 0.00-(2.92+/-7.56)e-5V-15V Power Supply A/D Converter ReadingNo Violation Check
p15vadc -3.171e-071.174e-0714.96 +/- 0.00-(4.74+/-10.21)e-5V+15V Power Supply A/D Converter ReadingNo Violation Check
p5vadc 3.783e-067.379e-074.94 +/- 0.00(7.42+/-5.60)e-4V+5V Power Supply A/D Converter ReadingNo Violation Check
tsctabadc -1.713e-040.0014.97 +/- 0.170.14 +/- 0.17VTSC Tab Position Sensor A/D converterNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Aug 10, 2023
Last Site Modification: Sep 30, 2021