| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| agrndadc | 2.841e-09 | 4.678e-09 | -(5.76+/-1.26)e-4 | (3.99+/-1.60)e-6 | V | Analog fround A/D convert reading | No Violation Check | |
| fatabadc | -5.716e-07 | 2.849e-06 | 4.99 +/- 0.08 | (1.73+/-3.07)e-4 | V | FA Tab Position Sensor A/D Converter | No Violation Check | |
| n15vadc | -1.363e-07 | 1.507e-08 | -15.02 +/- 0.00 | -(4.35+/-51.04)e-7 | V | -15V Power Supply A/D Converter Reading | No Violation Check | |
| p15vadc | 1.396e-07 | 1.482e-08 | 14.96 +/- 0.00 | -(4.78+/-61.82)e-7 | V | +15V Power Supply A/D Converter Reading | No Violation Check | |
| p5vadc | -2.122e-06 | 1.025e-07 | 4.94 +/- 0.00 | (3.78+/-2.99)e-5 | V | +5V Power Supply A/D Converter Reading | No Violation Check | |
| tsctabadc | 2.827e-06 | 6.154e-06 | 4.97 +/- 0.17 | -(3.49+/-12.78)e-4 | V | TSC Tab Position Sensor A/D converter | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 20, 2026