| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| agrndadc | -1.060e-04 | 1.515e-06 | -(7.46+/-2.64)e-4 | (5.14+/-3.79)e-5 | V | Analog fround A/D convert reading | No Violation Check | |
| fatabadc | -0.044 | 0.013 | 4.50 +/- 1.48 | 0.56 +/- 0.70 | V | FA Tab Position Sensor A/D Converter | No Violation Check | |
| n15vadc | 1.112e-05 | 4.270e-06 | -15.02 +/- 0.00 | (2.29+/-2.08)e-4 | V | -15V Power Supply A/D Converter Reading | No Violation Check | |
| p15vadc | 3.825e-04 | 0.003 | 14.95 +/- 0.36 | -(1.63+/-2.19)e-4 | V | +15V Power Supply A/D Converter Reading | No Violation Check | |
| p5vadc | -0.003 | 0.001 | 4.93 +/- 0.12 | 0.00 +/- 0.01 | V | +5V Power Supply A/D Converter Reading | No Violation Check | |
| tsctabadc | -0.057 | 0.021 | 3.03 +/- 2.41 | 0.30 +/- 1.16 | V | TSC Tab Position Sensor A/D converter | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Aug 07, 2026
Last Site Modification: Sep 30, 2021