Back to Top

SIMELEC
Static Version: Min --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
agrndadc -1.044e-041.482e-06-(7.50+/-2.65)e-4(3.14+/-4.05)e-5VAnalog fround A/D convert readingNo Violation Check
fatabadc -0.0490.0134.49 +/- 1.490.28 +/- 0.71VFA Tab Position Sensor A/D ConverterNo Violation Check
n15vadc 1.728e-054.156e-06-15.02 +/- 0.00(7.33+/-20.29)e-5V-15V Power Supply A/D Converter ReadingNo Violation Check
p15vadc 4.634e-040.00314.95 +/- 0.35-(1.70+/-2.31)e-4V+15V Power Supply A/D Converter ReadingNo Violation Check
p5vadc -0.0030.0014.93 +/- 0.12-0.00 +/- 0.01V+5V Power Supply A/D Converter ReadingNo Violation Check
tsctabadc -0.0580.0213.02 +/- 2.42-0.52 +/- 1.20VTSC Tab Position Sensor A/D converterNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Sep 16, 2026
Last Site Modification: Sep 30, 2021