Back to Top

SIMELEC
Static Version: Min --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
agrndadc -1.060e-041.515e-06-(7.46+/-2.64)e-4(5.14+/-3.79)e-5VAnalog fround A/D convert readingNo Violation Check
fatabadc -0.0440.0134.50 +/- 1.480.56 +/- 0.70VFA Tab Position Sensor A/D ConverterNo Violation Check
n15vadc 1.112e-054.270e-06-15.02 +/- 0.00(2.29+/-2.08)e-4V-15V Power Supply A/D Converter ReadingNo Violation Check
p15vadc 3.825e-040.00314.95 +/- 0.36-(1.63+/-2.19)e-4V+15V Power Supply A/D Converter ReadingNo Violation Check
p5vadc -0.0030.0014.93 +/- 0.120.00 +/- 0.01V+5V Power Supply A/D Converter ReadingNo Violation Check
tsctabadc -0.0570.0213.03 +/- 2.410.30 +/- 1.16VTSC Tab Position Sensor A/D converterNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Aug 07, 2026
Last Site Modification: Sep 30, 2021