Back to Top

SIMELEC
Static Version: Min --- Full Range

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
agrndadc -7.730e-055.248e-07-(1.60+/-7.65)e-4(5.45+/-4.40)e-6VAnalog fround A/D convert readingNo Violation Check
fatabadc -0.0060.0024.57 +/- 1.39-0.01 +/- 0.04VFA Tab Position Sensor A/D ConverterNo Violation Check
n15vadc -2.899e-043.401e-06-15.02 +/- 0.00(6.11+/-138.00)e-7V-15V Power Supply A/D Converter ReadingNo Violation Check
p15vadc 0.0100.00114.90 +/- 0.94-0.00 +/- 0.00V+15V Power Supply A/D Converter ReadingNo Violation Check
p5vadc 0.0033.499e-044.92 +/- 0.30(3.38+/-6.96)e-4V+5V Power Supply A/D Converter ReadingNo Violation Check
tsctabadc -0.0160.0033.27 +/- 2.350.13 +/- 0.07VTSC Tab Position Sensor A/D converterNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Sep 30, 2026
Last Site Modification: Sep 30, 2021