Back to Top

SIMELEC
Static Version: Min --- Last Three Months

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
agrndadc -1.068e-066.767e-08-(7.42+/-1.95)e-4-(2.95+/-33.34)e-6VAnalog fround A/D convert readingNo Violation Check
fatabadc 5.362e-051.129e-044.97 +/- 0.320.01 +/- 0.02VFA Tab Position Sensor A/D ConverterNo Violation Check
n15vadc 1.631e-071.126e-07-15.02 +/- 0.00(8.10+/-5.87)e-5V-15V Power Supply A/D Converter ReadingNo Violation Check
p15vadc -4.772e-061.780e-0714.96 +/- 0.00(3.02+/-1.26)e-4V+15V Power Supply A/D Converter ReadingNo Violation Check
p5vadc -3.736e-051.548e-064.94 +/- 0.01-(5.47+/-8.67)e-4V+5V Power Supply A/D Converter ReadingNo Violation Check
tsctabadc 6.043e-042.514e-044.88 +/- 0.71-(2.87+/-875.40)e-4VTSC Tab Position Sensor A/D converterNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Dec 18, 2025
Last Site Modification: Sep 30, 2021