Back to Top

SIMELEC
Static Version: Min --- Last Three Months

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
agrndadc -3.527e-086.037e-08-(7.93+/-1.70)e-4(1.55+/-3.31)e-5VAnalog fround A/D convert readingNo Violation Check
fatabadc -3.589e-059.886e-054.97 +/- 0.280.01 +/- 0.02VFA Tab Position Sensor A/D ConverterNo Violation Check
n15vadc 2.528e-061.292e-07-15.02 +/- 0.00-(2.93+/-8.76)e-5V-15V Power Supply A/D Converter ReadingNo Violation Check
p15vadc 7.520e-072.437e-0714.96 +/- 0.00(1.86+/-1.72)e-4V+15V Power Supply A/D Converter ReadingNo Violation Check
p5vadc 4.859e-051.307e-064.94 +/- 0.00(6.59+/-7.14)e-4V+5V Power Supply A/D Converter ReadingNo Violation Check
tsctabadc 1.394e-042.352e-044.90 +/- 0.66-0.03 +/- 0.09VTSC Tab Position Sensor A/D converterNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Jun 05, 2026
Last Site Modification: Sep 30, 2021