@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ @ @ @ MTA Monitoring Report 5/05/00 - 5/18/00 @ @ @ @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ Due to remus problems, some processed data are lost, possibly permanently. Currently, many of the mta monitoring data sets are on a process of rebuilding. As of May 18 (assuming up to 5/1 is backed up on a tape), MTA Task Missing? Location ------------------------------------------------------------ MTA monitoring 5/2-5/4 /data/mta/www/mp_reports MTA CTI several holes. /data/mta/www/mta_temp/mta_cti MTA focal temp recovered /data/mta/www/mta_temp/mta_fp MTA trending possibly some missing spots /data/mta/www/mta_temp/mta_trends MTA states no damages /data/mta/www/mta_temp/mta_states All /mta_trend/... are temporary directories. After recovered data and/or backup tapes are restored onto disks, they will be integrated back to the original locations. Note, some of the processes are now manually run, and won't be updated on 5/20 and 5/21. ************ CTI trend ************* No major changes are observed. Software Note: * There are several holes in data. This could be due to a format change in input data. * Ti Ka of CCD4 shows significant drop on the last day. This, however, seems to be due to unknown bugs. This could be related to the first problem. ************** MTA Problem Tracking ***************** No new problem was reported. The following msids keep coming. ESAPYI AWD3TQI AIOBP5CV AOVAMPWR AOFUNLST C28VMONB CUSOB28V CIUB5V CIUB15V AWD2TQI AWD5TQI AOAUTTXN SEHSE400 AWD6TQI Note: Since many problems have never examined, we will close all problems with priority 4 in a few weeks. ******** Trending *********** In grating voltage and rotion angle, most of msids with up or down ward trends are now clearly flattened. Gyro rate AOSUNEC1 sine curve turn down (peak ~dom 230). OHRMAPWR show a clear reverse U track and back to 59.0 (peaked 62.0) ************* Telemetry *********** On 5/9, 4MP5AV and 4MP28AV of Grating voltage and rotation show unusually high percentage of red warning. This could be due to MTA limit problem rather than a real problem. They reached 5V and 28V, respectively. *********** ACIS Focal Temperature ******** Acis focal plane temperature peaked three times: Day (DOY) Temp (C) 125.5 -113.5 127.9 -113.5 130.5 -113.5 133.3 -113.5 135.9 -113.5 138.5 -113.5 The peak values are much lower than that of the previous period (-106C). This is due to a new attitude (orbital) profile adopted by the operations team *********** Photon Page ************ Acis OBSID DETECTOR GRATING TARGET ANALYSIS --------------------------------------------------------- 834 ACIS-I NONE NGC4261 OK 906 ACIS-I NONE ABELL 1995 OK 641 ACIS-S HETG PROXIMA GEN OK 735 ACIS-I NONE SN1993J OK 682 ACIS-S HETG BHXB OK 380 ACIS-I NONE M 82 OK 681 ACIS=S HETG BHXB OK 512 ACIS-I NONE EMSS 1054.5-0321 OK 350 ACIS-S NONE NGC 4258 OK HRC OBSID DETECTOR GRATING TARGET ANALYSIS --------------------------------------------------------- 810 HRC-S LETG NGC 4258 OK Grating OBSID DETECTOR GRATING TARGET ANALYSIS --------------------------------------------------------- 810 HRC-S LETG NGC 4258 OK 641 ACIS-S HETG PROXIMA GEN OK 682 ACIS-S HETG BHXB MISSING ANALYSIS 681 ACIS-S HETG BHXB MISSING ANALYSIS