MTA Monitoring Report 09/21/01 - 09/27/01

Archive of all weekly reports

Archive of Monthly reports

Radiation

A powerful X-class solar flare erupted Monday morning, Sept. 24th, EPHIN triggered almost immediatly. Observations were suspended at: TIME=2001:269:22:30. The environment has yet to clear on day 271. Current restart projected for day 230 at 1 a.m.

ACIS/Radiation Environment correlations
Note the background rise, just before the observation cut-off, on DOM 795.




CTI Trend

Average of ACIS-I CCDs (MnKa) slope 1.419e-8 CTI/day
Detrended slope 1.324e-8 CTI/day

ACIS Warm Pixels

The following pixels consistently showed a bias level more than 5 sigma away the chip's mean level during this period.
For more information see the link above and MTA monthly reports.

ACIS Focal Temperature

For this period, 2 peaks were observed.

MTA Problem Tracking

Note: Problem Tracking system is currently not working properly. Many problems reported are not listed on the table.

SIM Movements

7 TSC moves this period
weekly average time/step 0.00151 s
mission average time/step 0.00136 s

Telemetry

9/21 9/22
This morning (22 Sept) Chandra entered a bright star hold at 7:48am (265/11+48) following a 2.5 hour observation of the dark moon performed on gyro-hold. Analysis of the dump data indicates that a gyro bias error of ~170 arcsec accumulated during the gyro hold and subsequent maneuver. The error exceeded the size of the aspect camera search box during the next star acquisition and resulted in the bright star hold. Data indicates that the gyro performance is consistent with past performance, however some further data analysis will be performed by the gyro vendor. 9/23 9/24 9/25 9/26 9/27

Recent Observations

The ACA Problem is in the specified handling of guide star positional errors.
This issue in not significant to the final product and so is being worked at low priority.
OBSID DETECTOR GRATING TARGET ANALYSIS ACA
1890 ACIS-S HETG HD93497 OK /NOT AVIL PROBLEM
1883 ACIS-I NONE MWC297 OK OK
1914 ACIS-S NONE SAXJ1752.3-3138 OK OK
2119 ACIS-S NONE 1WGA_J1233.3+6910 OK MISSING

Trending

This Week's focus GRAD
Temperatures in degrees K.
Current in Amps.
Voltage in Volts.

Most msids are keeping the same trends from the previous reporting period ( 07/06/01 - 07/12/01 weekly).