MTA Monitoring Report 12/20/02 - 12/26/02

Archive of all weekly reports

Archive of monthly reports

DPA A Problem

At the 2002:354:00:00-01:00 pass several limits tripped indicating the the ACIS DPA-A power was off. A description of the ACIS power configuration was similar to that from a previous occurrence of an anomalous DPA-A off on 2000:300. ACIS DPA side A was turned on at the 354:06:00 pass.

Radiation

Quiet

Detrended CTI

CTI analysis is now computed with "detrending":
Detrend CTI = Measured CTI + S3 amplitude reject rate * Detrend factor.

Average of ACIS-I CCDs (MnKa) slope 8.878e-9 CTI/day
Detrended slope 9.073e-9 CTI/day

ACIS Warm Pixels



ACIS Focal Plane Temperature

For this period, 2 peaks are observed, and a third one is raising at the end of day 360.

SIM Movements

10 TSC moves this period
weekly average time/step 0.00135 s
mission average time/step 0.00137 s

Telemetry

New violations or new extrema are indicated by *. Recurrent problems are tracked here.

MSID 12/20 12/21 12/22 12/23 12/24 12/25 12/26 yellow limits
(lower)
upper
red limits
(lower)
upper
Units Description
1CRAT           *154.80   (143.16)
148.16
(131.16)
183.16
K #COLD RADIATOR TEMP. A
1CRBT           *154.80   (143.16)
148.16
(131.16)
183.16
K #COLD RADIATOR TEMP. B
1DPICACU (0.41)             (0.90)
1.75
(-1000)
1000
AMP #DPA INPUT CURRENT A
1DPICBCU (0.46)             (0.70)
1.75
(-1000)
1000
AMP #DPA INPUT CURRENT B
1DPPWRA (11.94)             (23.4)
59.5
(-999)
999
W # DPA POWER A
1DPPWRB 7.68             (18.2)
59.5
(-999)
999
W # DPA POWER B
1PIN1AT               (268.16)
303.16
(236.66)
309.66
K #PSMC TEMP 1A
TEPHIN 305.68 306.88 307.48 307.48 *308.07     (260.8)
300.2
(258.0)
303.0
K #EPHIN SENSOR HOUSING TEMP
5EPHINT 305.79 306.21 306.64 306.64 *307.92     (261.0)
300.0
(258.0)
303.0
K #EPHIN TEMP
HKBBIASLEAKI 0.86 0.91 0.93 0.92 1.00 0.56   (-100.0)
0.5
(-200.0)
0.7
uA #EPHIN HOUSEKEEPING B-BIAS: LEAKAGE CURRENT (5EHSE500)
HKCBIASLEAKI   32.08 32.44 32.44 *37.05     (-100.0)
30.0
(-200.0)
40.0
uA #EPHIN HOUSEKEEPING C-BIAS: LEAKAGE CURRENT (5EHSE600)
HKDBIASLEAKI   36.43 36.79 36.79 *42.62     (-100.0)
36.0
(-200.0)
40.0
uA #EPHIN HOUSEKEEPING D-BIAS: LEAKAGE CURRENT (5EHSE700)
HKEBIASLEAKI 36.79 39.44 39.79 39.79 *45.10     (-100.0)
30.0
(-200.0)
40.0
uA #EPHIN HOUSEKEEPING E-BIAS: LEAKAGE CURRENT (5EHSE800)
HKEBOXTEMP 310.48 312.06 312.06 312.06 *312.60     (268.0)
308.0
(253.0)
343.0
K #EPHIN HOUSEKEEPING EBOX: TEMPERATURE (5EHSE300)
TEMPHOUS 288.35 288.35 288.35 288.35 288.35 288.35   (4.85)
288.0
(-22.95)
290.0
C #temp 2 - AC housing (AACH1T)
FAMTRTEMP   283.15 285.7 285.15 285.15     (260.0)
282.0
(255.0)
285.0
K #FA motor temperature
BOXTEMP     293.15 292.65 292.65     (278.0)
292.0
(276.0)
294.0
K #SEA box temperature
3TTHRC2T               (243.0)
293.0
(218.5)
353.0
K #TT AT HRC BIPOD ATTACH #2
3FAMYZAT               (253.0)
308.0
(225.0)
353.0
K #FA STRUCTURE +X FACE AT -Y-Z END ABORT HTR. FA6 TEMP
TSCIUSF1     354.41 359.12 354.41     (230.2)
346.9
(227.4)
349.7
K #SC-IUS FITTING-1 TEMP
TSCIUSF8     354.41 359.12 354.41     (230.2)
346.9
(227.4)
349.7
K #SC-IUS FITTING-8 TEMP
TCYLAFT1     295.45 296.93 *298.48     (260.8)
294.1
(227.4)
349.7
K #CNT CYL TEMP:16-IN FWD OF SC-TS FIT-1
TCYLAFT6     295.90 296.93 *297.96     (260.8)
294.1
(227.4)
349.7
K #CNT CYL TEMP:16-IN FWD OF SC-TS FIT-6
TMZP_CNT 328.78 332.41 332.41 333.98 *333.98     (237.4)
327.4
(227.4)
349.7
K #-Z PNL TEMP:CENTER
TFSSBKT1 338.70 340.27 341.84 341.84 *341.84     (237.4)
333.0
(223.0)
348.0
K #FSS BRACKET-1 TEMP (+Y)
TFSSBKT2 338.70 337.70 340.27 340.27 *340.27     (237.4)
333.0
(223.0)
348.0
K #FSS BRACKET-2 TEMP (-Y)
TPZLGABM       (207.85) (207.85) (207.85) (207.85) (208.0)
321.9
(206.0)
388.0
K #+Z LOW-GAIN ANTENNA BOOM TEMP
TRSPMTPC         294.55     (260.8)
294.1
(216.3)
349.7
K #RAD SHR PNL TEMP:TTWN MUPS AND PCAD
TMZLGABM               (244.1)
321.9
(208.0)
388.0
K #-Z LOW-GAIN ANTENNA BOOM TEMP
CSSR2CBV           4.96   (-1.0)
1.0
(-1.0)
1.0
V #SSR-2 CONVERTER B VOLTAGE
OOBTHR31               (281.9)
289.7
(250.2)
308.0
K #RT 53: OBA AFT BULKHEAD
OOBTHR56 289.46 289.28 289.28 289.19 289.46     (281.9)
288.6
(250.2)
308.0
K #RT 158: OBA CONE
OOBTHR57     289.37 289.19 288.74     (281.9)
288.6
(250.2)
308.0
K #RT 150: OBA CONE
Gratings HETG Insert  
HETG Retract LETG Insert LETG Retract LETG Insert LETG Retract
HETG Insert     

IRUs


Recent Observations

"Prob" means that there was probably bad time data included in the manual runs. This will be corrected in future processing.

OBSID DETECTOR GRATING TARGET ANALYSIS ACA
3554 ACIS-S NONE NGC1365 OK OK
3260 ACIS-I NONE MACS-J2243.3-0935 OK OK
3199 ACIS-I NONE MACS-J2129.4-0741 OK OK
3828 ACIS-S HETG 1E0102.2-7219 OK /Not yet avail. OK
3259 ACIS-I NONE MACS-J2214.9-135 OK Prob
3057 ACIS-S NONE 0156-25 OK OK
3012 ACIS-S NONE NGC1808 OK Prob
3240 ACIS-S NONE RCS1419+5326 OK OK
4145 ACIS-S NONE SDSSJ0300+0048 OK OK
4034 ACIS-S NONE 2MASS074825+694712 OK OK
2966 HRC-S LETG MR2251-17 OK /Not yet avail. OK

Trending

This Week's focus Ephin.

Trends last reported on Sep 26.
Only the most interesting or representative msids are shown below. For a full listing choose the bulletted link.

  • EPHIN Temperatures and Voltages

  • MSID MEAN RMS DELTA/YR DELTA/YR/YR UNITSDESCRIPTION
    5EIOT 3.250e+02 1.037e+01 5.306e+00 -6.328e+00 K EIO TEMP
    5EPHINT 2.876e+02 8.878e+00 7.294e+00 -1.620e+00 K EPHIN TEMP
    HKABIASLEAKI 7.012e-01 3.222e-01 2.542e-01 -1.552e-01 uA EPHIN HOUSEKEEPING A-BIAS: LEAKAGE CURRENT (5EHSE400)
    HKBBIASLEAKI 2.081e-01 1.771e-01 1.410e-01 7.564e-02 uA EPHIN HOUSEKEEPING B-BIAS: LEAKAGE CURRENT (5EHSE500)
    HKCBIASLEAKI 8.060e+00 5.580e+00 4.387e+00 1.766e+00 uA EPHIN HOUSEKEEPING C-BIAS: LEAKAGE CURRENT (5EHSE600)
    HKDBIASLEAKI 8.480e+00 6.163e+00 4.877e+00 2.745e+00 uA EPHIN HOUSEKEEPING D-BIAS: LEAKAGE CURRENT (5EHSE700)
    HKEBIASLEAKI 8.854e+00 6.450e+00 5.223e+00 3.175e+00 uA EPHIN HOUSEKEEPING E-BIAS: LEAKAGE CURRENT (5EHSE800)
    HKEBOXTEMP 2.928e+02 8.849e+00 7.222e+00 -1.740e+00 K EPHIN HOUSEKEEPING EBOX: TEMPERATURE (5EHSE300)
    HKFBIASLEAKI 1.882e-01 1.927e-01 1.542e-01 6.327e-02 uA EPHIN HOUSEKEEPING F-BIAS: LEAKAGE CURRENT (5EHSE900)
    HKP27I 4.332e+00 5.470e-01 4.373e-01 3.188e-01 AMP HK 27 Volts Rail - Current
    HKP5V 5.122e+00 9.973e-03 -2.531e-03 -4.590e-03 V HK 5 Volts Rail - Voltage
    TEIO 2.947e+02 1.205e+01 5.951e+00 -4.887e+00 K EPHIN ELECTRONICS HOUSING TEMP
    TEPHIN 2.878e+02 9.021e+00 7.335e+00 -1.933e+00 K EPHIN SENSOR HOUSING TEMP

  • EPHIN Rates/Leakage Current vs. Temperature

  • vs. Temperature
    MSID MEAN RMS DELTA/K DELTA/K/K UNITSDESCRIPTION
    HKABIASLEAKI 7.014e-01 3.215e-01 3.234e-02 -3.225e-04 uA EPHIN HOUSEKEEPING A-BIAS: LEAKAGE CURRENT (5EHSE400)
    HKBBIASLEAKI 2.083e-01 1.776e-01 1.744e-02 1.880e-03 uA EPHIN HOUSEKEEPING B-BIAS: LEAKAGE CURRENT (5EHSE500)
    HKCBIASLEAKI 8.054e+00 5.579e+00 5.719e-01 5.792e-02 uA EPHIN HOUSEKEEPING C-BIAS: LEAKAGE CURRENT (5EHSE600)
    HKDBIASLEAKI 8.506e+00 6.200e+00 6.294e-01 6.584e-02 uA EPHIN HOUSEKEEPING D-BIAS: LEAKAGE CURRENT (5EHSE700)
    HKEBIASLEAKI 8.877e+00 6.491e+00 6.538e-01 7.106e-02 uA EPHIN HOUSEKEEPING E-BIAS: LEAKAGE CURRENT (5EHSE800)
    HKEBOXTEMP 2.928e+02 8.868e+00 9.474e-01 5.599e-04 K EPHIN HOUSEKEEPING EBOX: TEMPERATURE (5EHSE300)
    HKFBIASLEAKI 1.878e-01 1.922e-01 1.955e-02 2.148e-03 uA EPHIN HOUSEKEEPING F-BIAS: LEAKAGE CURRENT (5EHSE900)
    HKP27I 4.331e+00 5.454e-01 5.637e-02 5.953e-03 AMP HK 27 Volts Rail - Current
    TEIO 2.946e+02 1.204e+01 1.109e+00 -1.958e-02 K EPHIN ELECTRONICS HOUSING TEMP